Note 

The wire gauge for the terminal block should be in the range 

between 12~ 24 AWG. 

 

 

Insert the wires into the fault alarm contact (No. 3 & 4) 

 

Содержание IPGS-0016

Страница 1: ...Lantech IPGS 0016 16 10 100 1000T Industrial Unmanaged PoE Ethernet Switch IPES 0016 16 10 100TX Industrial Unmanaged PoE Ethernet Switch User Manual V1 01 Mar 2022...

Страница 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Страница 3: ...fety Precaution 2 Hardware Description 3 Front Panel 3 Top View 4 Dimensions 4 Wiring the Power Inputs 6 Wiring the Fault Alarm Contact 6 LED Indicators 8 RJ 45 Pin Assignments 9 Cabling 11 Mounting I...

Страница 4: ...Hardware Installation 15 Installation Steps 16 Troubleshooting 17...

Страница 5: ...meets the high reliability requirements demanded by industrial applications Model Lists Model name 10 100 1000T ports 10 100TX ports PoE ports IPGS 0016 24V IPGS 0016 24V E 16 16 IPES 0016 24V IPES 0...

Страница 6: ...acking List 1 x 16 port Industrial Ethernet Switch 1 x Terminal Block Safety Precaution Attention If DC voltage is supplied by an external circuit please use a protection device on the power supply in...

Страница 7: ...DC DC converter between the power supply and the Ethernet switch on all Non Isolated units Please contact the sales team for advice on which units support isolated power supply In this paragraph we w...

Страница 8: ...ront Panel of the Industrial Switch Top View The top panel of the Industrial Switch is equipped one terminal block connector of two DC power inputs Top panel of the Industrial Switch Converter Dimensi...

Страница 9: ...5 The dimensions of IPGS 0016 IPES 0016 are 74 x 152 x 105 mm W x H x D The figure below gives the dimensions and views of each side of the 16 port Industrial Ethernet Switch...

Страница 10: ...al block connector 2 To tighten the wire clamp screws for preventing the DC wires to loose Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the pi...

Страница 11: ...7 Note The wire gauge for the terminal block should be in the range between 12 24 AWG Insert the wires into the fault alarm contact No 3 4...

Страница 12: ...input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional or no power inputs 1 16 Upper LED Green On Connected to network Flashing Networking is activ...

Страница 13: ...e figures below for straight through and crossover cable schema 10 100Base TX Pinouts Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wir...

Страница 14: ...below describes the gigabit Ethernet RJ 45 pinouts Pin Signal name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi directional pair B 4 BI_DC Bi directional pair C 5...

Страница 15: ...a Cabling Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 100 Category 3 4 or 5 cable for 10Mbps connections 100 Category 5 cable for 100Mbps or 100 Category 5...

Страница 16: ...the industrial switch when out of factory If not please refer to the following steps and figure to secure the DIN rail clip on the switch 1 Use the screws to screw on the DIN rail clip on the industri...

Страница 17: ...1 First position the rear side of the switch directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail 2 Push the unit downward 3 Check the DIN Rail clip is t...

Страница 18: ...Remove the DIN Rail bracket from the switch loose the screws to remove it 2 Place the wall mount bracket on the top side and bottom side of the switch 3 Use the screws to screw the wall mount bracket...

Страница 19: ...15 Hardware Installation In this paragraph we will describe how to install the 8 port 10 100 1000Base TX Industrial Switch and the installation points for the attention...

Страница 20: ...power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twiste...

Страница 21: ...at the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators The Switch can be easily monitored through panel indicators which describes common problems y...