Lantech IPES-0008A Series Скачать руководство пользователя страница 11

 

10 

2.3  IP Protection 

 

The 

IP Code

Ingress Protection Rating

, sometimes also interpreted as 

International 

Protection Rating

, classifies and rates the degree of protection provided against the 

intrusion (including body parts such as hands and fingers), dust, accidental contact, and 

water in 

mechanical casings

 and with electrical enclosures. It is published by the 

International Electrotechnical Commission (IEC) 

 

Solid particle protection 

The first digit indicates the level of protection that the enclosure provides against access 

to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid 

foreign objects. 

 

Level 

Object size 

protected against 

Effective against 

— 

No protection against contact and ingress of objects 

>50 mm 

Any large surface of the body, such as the back of a 

hand, but no protection against deliberate contact 

with a body part 

>12.5 mm 

Fingers or similar objects 

>2.5 mm 

Tools, thick wires, etc. 

>1 mm 

Most wires, screws, etc. 

Dust protected 

Ingress of dust is not entirely prevented, but it must 

not enter in sufficient quantity to interfere with the 

satisfactory operation of the equipment; complete 

protection against contact 

Dust tight 

No ingress of dust; complete protection against 

contact 

 

Содержание IPES-0008A Series

Страница 1: ...IPES IES 0008A Series 8 10 100TX w 8 PoE at af Industrial Un Managed Switch User Manual IP 67 IP 43 Apr 2014...

Страница 2: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Страница 3: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Страница 4: ...tent Chapter 1 Introduction 4 Specification 4 Chapter 2 Hardware Description 7 2 1 Physical Dimension 7 2 2 Package Content 9 2 3 IP Protection 10 2 4 LED Indicators 13 Chapter 3 Hardware Installation...

Страница 5: ...00pps for Fast Ethernet port Mac Address 8K MAC address table Connector 10 100T 8 x M12 4 pole D coded Female with auto MDI MDI X function Power connector 1 x M12 5 pole A coded Male Protocol CSMA CD...

Страница 6: ...ac Address 8K MAC address table Connector 10 100T 8 x M12 4 pole D coded Female with auto MDI MDI X function Power connector 1 x M23 5 pole A coded Male Relay contact 1 x M12 5 pole A coded Protocol C...

Страница 7: ...in Rail Wall Mount Design EMC FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 Magnetic Field CE EN61000 6 2 CE EN61000 6 4 St...

Страница 8: ...ardware Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension Aluminum case IP 67 285 W x 201 4 D...

Страница 9: ...8 Port description of IP 67 series switch Aluminum case IP 43 273 W x 188 4 D x 84 4 H mm The port description of IP 43 model is the same as of IP 67 one...

Страница 10: ...9 2 2 Package Content Manual CD Product Console cable...

Страница 11: ...t access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Level Object size protected against Effective against 0 No protection against contact and in...

Страница 12: ...o 15 from its normal position Test duration 10 minutes Water equivalent to 3 mm rainfall per minute 3 Spraying water Water falling as a spray at any angle up to 60 from the vertical shall have no harm...

Страница 13: ...30 minutes Immersion at depth of at least 1 m measured at bottom of device and at least 15 cm measured at top of device 8 Immersion beyond 1 m The equipment is suitable for continuous immersion in wat...

Страница 14: ...r the switch LED Color Status Meaning PWR1 Green On Power 1 is active Off Power 1 is inactive PWR2 Green On Power 2 is active Off Power 2 is inactive FAULT Red On Power or port failure Off No failure...

Страница 15: ...d devices or 54VDC for IEEE 802 3at standardized ones For IPES 0008A 12V series the power input voltage can be from 9 2V to 56VDC to feed power on both the 802 3af and 802 3at standardized devices Wit...

Страница 16: ...om the housing Note With single power supply of the mains voltage the device will report a power failure You can disable this power fail event via web browser Pin assignment of alarm relay A break in...

Страница 17: ...the power supply plug then turn on the power supply Ground The chassis is grounded via a separate ground nut M3 Use toothed locking washers for a good electrical connection Ground screw of IPES 0008A...

Страница 18: ...of LED make sure the switch was in working status Note The protection class IP67 IP43 is only achieved when bolted together The other components attaching to the system have to meet with the IP67 IP43...

Страница 19: ...18 Empty ports must be sealed with the protective caps supplied...

Отзывы: