FCC Warning 

 

This  Equipment  has  been  tested  and  found  to  comply  with  the limits  for  a 

Class-A  digital  device,  pursuant  to  Part  15  of  the  FCC  rules.  These  limits 

are designed to provide reasonable protection against harmful interference 

in  a  residential  installation.  This  equipment  generates,  uses,  and  can 

radiate radio frequency energy. It may cause harmful interference to radio 

communications  if  the  equipment  is  not  installed  and  used  in  accordance 

with  the instructions.  However,  there is  no  guarantee  that interference  will 

not  occur in  a  particular installation.  If  this  equipment  does  cause harmful 

interference  to  radio  or  television  reception,  which  can  be  determined  by 

turning  the  equipment  off  and  on,  the  user is  encouraged  to  try  to  correct 

the interference by one or more of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to 

which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

 

CE Mark Warning 

 

This  is  a  Class-A  product.  In  a  domestic  environment  this  product  may 

cause  radio  interference  in  which  case  the  user  may  be  required  to  take 

adequate measures. 

 

 

 

 

 

 

Содержание IGS-5424

Страница 1: ...IPGS 5424 IGS 5424 24 10 100 1000T 4 Dual Speed SFP L2 24 PoE at af Industrial Managed Switch w ITU G 8032 Ring User Manual Hardware Feb 2020...

Страница 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Страница 3: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Страница 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Страница 5: ...Hardware installation 11 3 1 Rack Mounting 12 3 2 Wiring the Power Inputs 14 3 3 Wiring the Fault Alarm Contact 16 3 4 Cabling 17 3 5 USB Dongle 20 Chapter 4 Network Application 21 ITU G 8032 Scheme 2...

Страница 6: ...hapter 1 Introduction Lantech IPGS IGS 5424 is a high performance L2 managed industrial switch which provides L2 wire speed and advanced security function for network aggregation and backbone deployme...

Страница 7: ...2 Hardware Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension Metal case IP 30 440 W x 325 D...

Страница 8: ...t access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Level Object size protected against Effective against 0 No protection against contact and in...

Страница 9: ...est duration 10 minutes Water equivalent to 3 mm rainfall per minute 3 Spraying water Water falling as a spray at any angle up to 60 from the vertical shall have no harmful effect Test duration 5 minu...

Страница 10: ...at least 1 m measured at bottom of device and at least 15 cm measured at top of device 8 Immersion beyond 1 m The equipment is suitable for continuous immersion in water under conditions which shall...

Страница 11: ...ive Off Power 1 is inactive PWR2 Green On Power 2 is active Off Power 2 is inactive FAULT Red On Power or port failure Off No failure RJ 45 Link Ack On A network device is detected Blinking The port i...

Страница 12: ...ial switch will light up For PoE model please connect power supply of PoE before system power Otherwise the PoE function will not work correctly 5 Prepare the twisted pair straight through Category 5...

Страница 13: ...quipment rack brackets included with the switch Cross head screwdriver not provided Four standard equipment rack screws not provided Perform this procedure to install the switch in a 19 inch equipment...

Страница 14: ...13...

Страница 15: ...system power input 1 and 2 The power input module 2 is optional part 1 Insert DC power wires into the contacts and for power 1 or and 1 for power 2 2 Tighten the wire clamp screws for preventing the...

Страница 16: ...15 NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG...

Страница 17: ...e switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for w...

Страница 18: ...tor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting Gigabit speed up to 1000Mbps They are used...

Страница 19: ...18 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver...

Страница 20: ...follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceive...

Страница 21: ...20 3 5 USB Dongle The USB slot is to backup and restore the setting of switch automatically by any USB dongle It doesn t need any configuration from web browser or other user interface...

Страница 22: ...munication Unit G 8032 v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 has defined the protocol scheme parameters functions test measures to be unified that the users c...

Страница 23: ...22 Multiple Rings...

Страница 24: ...23 Dual Homing...

Страница 25: ...24 Chain...

Страница 26: ...25...

Страница 27: ...cable which one end is DB9 female connector and the other end is DB9 male connector Attach the end of DB9 female connector to PC or terminal and the other end of DB9 male connector to the console port...

Страница 28: ...f the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished the parameter settings click OK When the blank scr...

Страница 29: ...28 Console login interface Notice For web based management please refer to our Software Management Manual at http www lantechcom tw global eng support downloads html...