24
3
Spraying
water
Water falling as a spray at
any angle up to 60° from
the vertical shall have no
harmful effect.
Test duration: 5 minutes
Water volume: 0.7 litres per
minute
Pressure: 80
–100 kPa
4
Splashing
of water
Water splashing against
the enclosure from any
direction shall have no
harmful effect.
Test duration: 5 minutes
Water volume: 10 litres per
minute
Pressure: 80
–100 kPa
5
Water jets
Water projected by a
nozzle (6.3 mm) against
enclosure from any
direction shall have no
harmful effects.
Test duration: at least
15 minutes
Water volume: 12.5 litres per
minute
Pressure: 30 kPa at distance
of 3 m
6
Powerful
water jets
Water projected in powerful
jets (12.5 mm nozzle)
against the enclosure from
any direction shall have no
harmful effects.
Test duration: at least
3 minutes
Water volume: 100 litres per
minute
Pressure: 100 kPa at
distance of 3 m
7
Immersion
up to 1 m
Ingress of water in harmful
quantity shall not be
possible when the
enclosure is immersed in
water under defined
conditions of pressure and
time (up to 1 m of
submersion).
Test duration: 30 minutes
Immersion at depth of at
least 1 m measured at
bottom of device, and at least
15 cm measured at top of
device
8
Immersion
beyond 1 m
The equipment is suitable
for continuous immersion in
water under conditions
which shall be specified by
Test duration: continuous
immersion in water
Depth specified by
manufacturer
Содержание IES-5208DF Series
Страница 17: ...16 Optional...
Страница 20: ...19 IES 5208DF 43 Aluminum case IP 43 203mm W x187mm H x84 4mm D...
Страница 21: ...20 Port description of IPES 5208T X...
Страница 22: ...21 Port description of I P ES 5208DF...
Страница 32: ...31 Pin assignment of M12 10 100Tx network connector Pin assignment of M12 10 100 1000T network connector...
Страница 35: ...34 4 3 Multiple Rings...
Страница 36: ...35 4 4 Dual Homing 4 5 Chain...
Страница 37: ...36...