![LANSITEC 100-13248 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/lansitec/100-13248/100-13248_manual_4573454003.webp)
Smart LoRaWAN Bluetooth Gateway
3
/
25
Operating
Humidity
5% ~ 95%
Battery
Connected
to
power source
Li-ion
600mAh
rechargeable
5300mAh,
Lithium
rechargeable
2 x 19,000mAh,
lithium
thionyl
chloride
non-
chargeable
battery
Power
DC 5V/1A
DC 5V/1A
Solar-powered
Do NOT charge
this product and
battery
Dimension
120 x 120 x 31 mm
97 x 62 x 7 mm
150 x 90 x 62 mm
150 x 90 x 60 mm
4.
Application Information
4.1
Function
The gateway supports both OTAA and ABP mode. The indoor gateway and compact gateway work on
class C mode while outdoor or macro gateway work on class A mode. The data rate is limited from DR3 to
DR5 to transmit 115 bytes payload at a time. DevEUI, AppEUI, and AppKey, or DevAddr, NwkSKey, and
AppSKey are stored in the gateway and are necessary for joining a network. Please find DevEUI or
DevAddr labeled at the back of the device. Lansitec helps to configure these parameters before shipping,
if required. After power is turned on and after it joins the LoRa network, the gateway sends a registration
message that includes the gateway's current parameters setting to the Customer Server (CS).
The gateway reports the heartbeat message to CS periodically. The duty cycle is configurable by
commands from CS. Coordinate acquisition and report period depends on the Bluetooth receiving results.
According to LoRaWAN specification, the downlink response time is decided by the uplink duty cycle in
Class A. The heartbeat period is configurable to be an integral multiple of 30 seconds. The default HB
period is 5 minutes. Heartbeat message also contains status information of the gateway. CS can use it to
monitor the gateway.
The Bluetooth gateway forwards Bluetooth beacons (UUID
F2-A5-2D-43-E0-AB-48-9C-B6-4C-4A-83-00-
14-67-20
), tags or bracelets received and forwards the corresponding information to LoRaWAN gateway.
If it receives a tag multiple times in one Bluetooth receiving duration, it only reports the latest one.
Please refer to:
990-00170 "B-Fixed® PERSONNEL& ASSET TRACKING SOLUTION" to find how to design and develop your
tracking system.
4.2
Application Scenarios
The gateway follows the general rules below:
When a registration request is received from the gateway,
-
If CS only wants the gateway to work with default parameters, CS ignores the registration
message and waits for the periodically report.