LANSING LIGHTING TY10D Скачать руководство пользователя страница 3

Shanghai Lansing Electronics Co., Ltd

Tel : +86 021 39921107

Fax:+86 021 39921107

Web:www.lansinglight.com E-mail[email protected]

Add: No 609, Tahui Rd, Shihudang Town, Songjiang Dist Shanghai, China, 201612

All rights reserved by Lansing,without the written authorization of the Lansing, any part thereof shall not be reproduced or transmitted in any form.

TY10D LED Dual Low Intensity Solar
Powered Obstruction Light (Type A)

3 / 7

3 / 7

Compliance with

• ICAO Annex 14, Volume I,

Obstruction Light Low Intensity Type A

• FAA AC No. 150/5345-43, L-810

• DGAC Mexico

TY10DA

TY10DA is updated with a flash frequency adjustable switch, which can set 40, 50, 60, 70 and

90 FPM (Flash per minute). Additional, a Dry Contact Relay is built in the light to report light

failure to central monitoring devices, in case of working with junction box or control box.

Alarm report conditions:

• Lamp low current(when lamp current falls<50%)

• Solar panel failure

• Battery fail

TY10DW

TY10DW is further updated from TY10DA, which can realize both Flashing Frequency

Adjusting&Alarm

Reporting functions, through built in 2.4G wireless module.

In case of working with our wireless control box, TY10DW can report failure status to central

monitoring in the BTS. Distance between TY10DW& receiver should be <100meters

Alarm report conditions:

• Lamp low current(when lamp current falls<50%)

• Solar panel failure

• Battery fail

Ordering Code

TY10D

TY10DA

TY10DW

Basic functions

Flashing frequency adjustable

Synchronization

Light failure alarm report

Wireless

Note: Synchronization & alarm report functions need junction box or control box to be

in the system

Содержание TY10D

Страница 1: ...ovides good protection against hash environments Features Benefits High quality optics for excellent beam spread control Ultra light LEDs energy saving Self contained without outside power supply Maxi...

Страница 2: ...Green White Yellow or Blue Nominal Night Range 3 6KM Horizontal Output degree 360 Vertical Divergence 0 to 7 Reflector Type Omnidirectional 360 LED Reflector Led life Expectancy hours 100 000 Operatin...

Страница 3: ...lay is built in the light to report light failure to central monitoring devices in case of working with junction box or control box Alarm report conditions Lamp low current when lamp current falls 50...

Страница 4: ...lansinglight com Add No 609 Tahui Rd Shihudang Town Songjiang Dist Shanghai China 201612 All rights reserved by Lansing without the written authorization of the Lansing any part thereof shall not be...

Страница 5: ...d in any form TY10D LED Dual Low Intensity Solar Powered Obstruction Light Type A 5 7 5 7 Installation and operation Option 1 1 Secure the light on a smooth surface which has enough strength if there...

Страница 6: ...ndustrial alcohol banana oil isopropyl alcohol carbon tetrachloride cyclohexanone and so on otherwise the product will be corrosion Please read the instruction manual carefully before operation For pr...

Страница 7: ...Low Intensity Solar Powered Obstruction Light Type A 7 7 7 7 BATTERY CHARGING IF NECESSARY FIRST WAY Put the light under sunlight SECOND WAY Use a Charger around 4 2v 5v such as switching power supply...