![Lanner LEC-6021A Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/lanner/lec-6021a/lec-6021a_user-manual_675123024.webp)
LEC-6021A User Manual
24
Connecting Power
Connect the device to an 18~48 VDC power source. The power source comes from the AC/DC Adapter
through a Phoenix contact. This power socket is specially designed to guard against fault in power contact, i.e.,
the reverse of the electrical polarity will not damage the system.
Note
: This product is intended for use with a UL-listed ITE DC power source, rated 18-48Vdc,
3.33-1.25A, operating at 70 C/min Tma and at 2000m operation altitude. If you need further assistance
with purchasing the appropriate power source, please contact Lanner Electronics Inc. for more
information.