background image

19

Bios Settings

Chapter 4

Network Application Platforms

Lanner Generation 2 LAN Bypass Configuration

In this screen, you can configure the Lan Bypass 

functionality. The system can accommodate one LAN 

module.

LAN Bypass for Ethernet Expansion Module

You can activate or deactivate the LAN Bypass ports. For 

the description of the physical ports that are capable of 

the LAN Bypass function, refer to the 

Front Panel Feature

 in

 

Chapter 1 Introduction

.

Note:

 the Ethernet expansion module may 

support Lanner  Generation 2 or Generation 3 

Bypass depending on the module specification.  

See appendix D Programming Generation 2 and 3 

LAN Bypass for more information

Runtime and Power off Bypass Settings

You can enable or disable the automatic activation of 

hardware LAN Bypass function in the event of a power 

failure. Hardware Bypass can automatically activate to 

allow network traffic to continue.
The LAN bypass can be turned on or off in two system 

states, i.e., power on and power off. The following are 

the BIOS menu and illustration of the possibilities of LAN 

bypass configuration in each state. Note that according to 

the result from table 2, the ports are not bypassed in both 

Power-on or Power-off state when the setting “Power off 

LAN Bypass for Module 1” is disabled.

Bypass settings in the BIOS

System Status

Runtime LAN Bypass for 

Module 1

Power off LAN Bypass for 

Module 1

Enabled

Disabled

Enabled

Power on

Bypass

Non-Bypass

Power off

Bypass

Bypass

Bypass settings in the BIOS

System Status

Runtime LAN Bypass for 

Module 1

Power off LAN Bypass for 

Module 1

Enabled

Disabled

Disabled

Power on

Non-Bypass Non-Bypass

Power off

Non-Bypass Non-Bypass

Содержание FW-7551

Страница 1: ...Network Application Platforms Hardware platforms for next generation networking infrastructure FW 7551 V1 3 User s Manual Date Y M D 2017 05 09...

Страница 2: ...ers Compliances CE This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to pro...

Страница 3: ...ance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a commercial area is likely to cause harmful interference in which case users wil...

Страница 4: ...ez r guli rement la valeur de r sistance du bracelet antistatique qui doit tre comprise entre 1 et 10 m gohms Mohms Consignes de s curit lectrique Avant d allumer l appareil reliez le c ble de mise la...

Страница 5: ...d Information 7 Block Diagram 7 Motherboard Layout 8 Jumper Settings 9 Chapter 4 BIOS Settings 13 Accessing the BIOS menu 13 Navigating the BIOS menu 13 The Main Menu 14 Advanced Settings 15 Intel RCS...

Страница 6: ...nstallation and acquiring the Intel Atom Processor C2000 Product Family for Communications Infrastructure Software for Linux Software package refer to the attached PDF file Form Factor Desktop Platfor...

Страница 7: ...Adapter Input 100 240V 50 60Hz Approvals and Compliance CE FCC Class B RoHS Ordering Information FW 7551A Intel Atom processor C2358 Code named Rangeley 1x DDR3 SO DIMM socket 6 GbE LAN ports with Gen...

Страница 8: ...system s operational state is normal If it is red it indicates that the system is malfunctioning HDD If the LED blinks it indicates data access activities otherwise it remains off F2 These LEDs are in...

Страница 9: ...r 4 ofall6 on boardEthernetportsequipwith2pairsofLANbypass These4GbEportsareprovidedbyMarvell88E1543and the other two are provided by Intel i210AT LAN1 is capable of Preboot eXecution Environment PXE...

Страница 10: ...andwidth requirements of the latest operating system and Internet applications To install the memory 1 Open the DIMM slot latches 2 Install the DIMM Note 1 The system requires DDR3 1333 1600 MHz ECC m...

Страница 11: ...talling the CompactFlash Card FW 7551 provides one CompactFlash slot Follow the procedures bellow for installing a CompactFlash card 1 Align CompactFlash card and the card slot with the arrow pointing...

Страница 12: ...r C2358 Codenamed Rangeley LPC 6x GbE RJ 45 Connectors w LED 2x PCI E x1 Dual Channel DDR3 1333 1600 MHz ECC DIMM only Up to 8GB Maximum 2x SATA connectors 1x 2 5 CF 2x USB PIN header 2x USB connector...

Страница 13: ...ard Layout The motherboard layout shows the connectors and jumpers on the board Refer to the following picture as a reference of the pin assignments and the internal connectors PS1 GPIO1 DIMM1 CF1 SAT...

Страница 14: ...upport up to 480 Mbps connection speed Dual USB 2 0 Ports USB1 This provides two USB 2 0 ports in the front panel Console Port COM1 Pin No Signal 1 P5V_ATX 2 GND 3 GND 4 P12V 5 P3V3_ATX 6 GND 7 P5VSB_...

Страница 15: ...unction 1 GND 26 DET1 2 CF_DD3 27 CF_DD11 3 CF_DD 4 28 CF_DD 12 4 CF_DD 5 29 CF_DD 13 5 CF_DD 6 30 CF_DD 14 6 CF_DD 7 31 CF_DD 15 7 CF_DCS0 32 CF_DCS1 8 GND 33 CF_VS1 9 GND 34 CF_DIOR_N 10 GND 35 CF_D...

Страница 16: ...t have AHCI capabilities The AHCI Advanced Host Controller Interface is a programming interface which defines transactions between the SATA controller and software and enables advanced performance and...

Страница 17: ...I_CLKREQ_N1 33 MINI_PCIE_TXP0 8 NC_UIM_PWR 34 GND 9 GND 35 GND 10 NC_UIM_DATA 36 USB_IO3_DN 11 MINIPCIE_REFCLKN 37 GND 12 NC_UIM_CLK 38 USB_IO3_DP 13 MINIPCIE_REFCLKP 39 VCC3 14 NC_UIM_RST 40 GND 15 G...

Страница 18: ...or by pressing the reset button on the system chassis You can also restart by turning the system off and then back on Do this last option only if the first two failed The Setup program is designed to...

Страница 19: ...blue can be modified The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often...

Страница 20: ...by highlighting it using the Arrow keys All Advanced BIOS Setup options are described in this section The Advanced BIOS Setup screen is shown at the right The sub menus are described on the following...

Страница 21: ...l port Device Settings Shows the serial port base address and the IRQ port Change Settings Selects the port base address and the IRQ port Parallel port Configuration Item Selection Parallel Port Enabl...

Страница 22: ...the smart fan feature You can manually turn on the CPU fan or set the target CPU temperature at which the CPU fan will start running if the fanisnotyetturnedon AndtheCPUfancanalsobeturned off automat...

Страница 23: ...direction Enable or disable BIOS through remote access Console Redirection Set tings Enter to view more options COM0 Console Redirection Settings Item Selection Terminal Type Sets the connection termi...

Страница 24: ...automatic activation of hardware LAN Bypass function in the event of a power failure Hardware Bypass can automatically activate to allow network traffic to continue The LAN bypass can be turned on or...

Страница 25: ...ompatible operating system is fully booted with all USB drivers loaded When this option is enabled any attached USB mouse or USB keyboard can be used on the system even when there is no USB drivers lo...

Страница 26: ...l not cancel the transfer In this case the transfer waits indefinitely until it is manually canceled or the transfer completes normally If set to a nonzero value time out inter val the host controller...

Страница 27: ...CPU from overheating Enable or disable this feature CPU C State CPU operating states C states are the capability of an idle processor to turn off unused components to save power En able or disable or...

Страница 28: ...ion Description Power Off When setting to Power Off the system goes into off state after an AC power interruption Power On When setting to Power on the system turns on automatically after a power inte...

Страница 29: ...ble the SATA controller Serial ATA Port 0 1 2 3 Use this menu to configure specific SATA Port for all ports on the system Option Description Staggered Spin Up Spin up is a simple mechanism by which th...

Страница 30: ...word If you have set a user password you must enter the user password for booting and accessing the system however some functions may be disabled To set an Administrator User password 1 Select the opt...

Страница 31: ...Specify the number of seconds for the boot setup prompt to wait for user s intervention during the POST Bootup Num Lock State This option lets you to enable or disable the function of the NumLock key...

Страница 32: ...ave setup and reboot the computer so the new system configuration parameters can take effect Discard Changes and Reset This option allows you to discard the selections you made and restore the previou...

Страница 33: ...e counter reach zero before the software restarts it the software is presumed to be malfunctioning and the processor s reset signal is asserted Thus the processor will be restarted as if a human opera...

Страница 34: ...to console port of the system and the other end to serial port of the Remote Client System 2 Configure the following settings in the BIOS Setup menu BIOS Advanced Serial Port Console Redirection Conso...

Страница 35: ...t 2 LAN Bypass 1 2 when power off Enabled Disabled Disabled PWR ON Non Bypass Non Bypass PWR OFF Non Bypass Non Bypass 2 A watchdog timer can be used to control the LAN Bypass function dynamically by...

Страница 36: ...c Functions Cipher Operations Hash Authenticate Operation Cipher Hash Combined Operation Key Derivation Operation Public Key Functions RSA Operation Diffie Helman Operation Digital Signature Standard...

Страница 37: ...ll be returned at customer s expense 5 The following conditions are excluded from this warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineer...

Страница 38: ...ing by Air Freight Sea Express ___ Others ________________ Item Model Name Serial Number Configuration Item Problem Code Failure Status Problem Code 01 D O A 02 Second Time R M A 03 CMOS Data Lost 04...

Отзывы: