17
9.4
Installation of a replacement device (hole spacing 80 mm)
Fig. 14
Fig. 15
If mounting holes
(1)
already exist
(thread spacing 80 mm), a
predetermined breaking point
(2)
can
be opened in the bottom part
(3)
of the
device.
•
Remove the plastic caps (captive)
(4)
.
•
Open the predetermined breaking point
(2)
and deburr.
•
Fasten the bottom part
(3)
of the device
to the pole with 2 M6x25 fastening
screws
(5)
.
•
Note:
- Torque = 5 Nm.
- Check that the pedestrian signal
requesting device is fitted correctly
on the pole.
•
Close the upper housing hole with a
sealing plug
(1)
(yellow
– accessories
kit).
•
Turn the plastic caps (captive)
(2)
downwards and attach to the fastening
screw.
Note: Check that they are fitted
correctly. (Protection class!)
•
Connect the connection cable to the
cable distributor in accordance with the
block diagram (see chapter 4).
•
Unused cores must be insulated.
A function test must be carried out
when the pedestrian signal requesting
device has been installed!