9
GENERAL INSTALLATION DATA (continued)
PILOT LIGHTING INSTRUCTIONS
The range is equipped with an automatic pilot/ignter with an electronic spark.
Be sure all gas control knobs on the units front panel are turned OFF.
Turn on main gas supply valve to unit.
Turn "ON" the switch on front control panel to activate electonic pilot lighter.
The pilots on this broiler have been pre-set at the factory. Turn the adjustable screw
counterclockwise to open and clockwise to close.
Adjust pilot light flames, if necessary as small as possible, but high enough to light burner
immediately when burner valve is turned on high.
Turn burner knobs to desired setting.
To turn burners off, turn knobs to "OFF" and turn "OFF" switch on front control panel.
BURNER IGNITION AND ADJUSTMENT
To ignite burners turn burner valve knob counter clockwise to "ON"position.
Slowly decrease openings of air shutters to give a soft blue flame having luminous tips, then
slowly increase openings to a point where the yellow tips disappear and a hard blue flame is
obtained.
INITIAL LIGHTING
When range is first lit, it will smoke for approximately 20-30 minutes until the preservation oils
and impurities from the manufacturing process are burned off.
DO NOT ATTEMPT TO OPERATE UNIT DURING A POWER FAILURE.
1.
2.
3.
4.
5.
6.
7.
1.
2.
2M-W1662 Operation Manual - Lang Gas Countertop Range, GHP
Series
2M-W1662 Operation Manual - Lang Gas Countertop Range, GHP
Series