3
IMPORTANT READ
FIRST IMPORTANT
CAUTION
THE OVEN WEIGHS 500 LBS. FOR SAFE HANDLING, INSTALLER
SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE
MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR
PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO
THE PLACE OF INSTALLATION.
CAUTION
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH THE OVEN WILL
BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE
OVEN.
CAUTION
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN
CUT.
WARNING
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED
TO WORK WITH PLUMBING. IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST
BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE
The data plate is located above control panel behind wire mesh screen.
The oven serial number, gas specifications, and clearance specifications
are on the data plate. This information should be carefully read and
understood before proceeding with the installation.
NOTICE
The installation of any components such as a vent hood, grease
extractors, fire extinguisher systems, must conform to their applicable
National, State and locally recognized installation standards.
WARNING
THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG (GROUNDING) PLUG
FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND MUST BE
PLUGGED DIRECTLY INTO A PROPERLY GROUNDED 3-PRONG
RECEPTACLE. DO NOT CUT OR REMOVE THIS GROUNDING PRONG
FROM THE PLUG.
WARNING
CONVECTION OVENS INSTALLED WITH CASTERS MUST HAVE THE
FOLLOWING: A CONNECTOR THAT COMPLIES WITH THE STANDARD
FOR CONNECTORS FOR MOVABLE GAS APPLIANCES ANSI Z21.69
LATEST EDITION, A QUICK DISCONNECT THAT COMPLIES WITH THE
STANDARD FOR QUICK DISCONNECT DEVICES FOR USE WITH GAS
FUEL, ANSI Z21.141 LATEST EDITION, A TETHER OR OTHER MEANS TO
LIMIT APPLIANCE MOVEMENT WITH OUT RELIANCE ON THE GAS
SUPPLY PIPING. SECURELY ATTACH THE TETHER TO THE EYEBOLT
PROVIDED AT THE REAR OF THE APPLIANCE.
NOTICE
Kits designed to accommodate ovens from sea level to 5000 feet. Contact
factory for orifice sizes on installations above 5000 feet.
WARNING
BEFORE LIGHTING, USE A SOAP AND WATER SOLUTION TO TEST ALL
JOINTS FOR GAS LEAKS.
NOTICE
During the first few hours of operation you may notice a small amount of
smoke coming off the oven, and a faint odor from the smoke. This is
normal for a new oven and will disappear after the first few hours of use.
CAUTION
ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM
COMBUSTIBLE MATERIALS.
Содержание GCCO-C
Страница 29: ...29 GENERAL CONT D ONE PAN TWO PAN THREE PAN FOUR PAN FIVE PAN ...
Страница 59: ...59 TECHNICAL DATA CONT D GCCO C TEST POINT LAYOUT TP 2 TP 1 TP 3 TP 4 TP5 TP6 TP7 ...
Страница 61: ...61 WIREING DIAGRAM GCCO T ...
Страница 62: ...62 WIRING DIAGRAM GCCO AP ...
Страница 63: ...63 WIRING DIAGRAM GCCO SII ...
Страница 64: ...64 WIRING DIAGRAM GCCO C ...
Страница 65: ...65 WIRING DIAGRAM GCCO PP ...
Страница 66: ...66 WIRING DIAGRAM GCCO PT ...
Страница 73: ...73 THIS PAGE INTENTIONALLY LEFT BLANK ...