5. INSTALLATION
DANGER
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN
ELECTROCUTION AND DEATH.
CAUTION
The data plate is located on the back of the oven. The oven voltage,
wattage, serial number, wire size, and clearance specifications are on the
data plate. This information should be carefully read and understood
before proceeding with the installation.
NOTICE
The installation of any components such as a vent hood, grease extractors, fire
extinguisher systems, must conform to their applicable Nationally recognized
installation standards.
4.1 Electrical Connection
The oven is supplied with a cord and plug connected. The plug provided is a NEMA-
L6-20P. The receptacle is not provided with the oven. The installer should install a
NEMA-L6-20R
close enough to the oven for the plug to reach the outlet.
Follow the receptacle manufacturer’s instructions when connecting the receptacle to
the power supply.
4.2 Oven Voltage
The Lang Model EQS oven can be operated on 208 Volts or 240 Volt source. The
Amp draw and KW rating at both voltages are listed in the table below.
Model Volt Kw Amperage
1Phase
208.0
3.0 14.0
ECOQ-AP
240.0
3.9 16.0