background image

8

INITIAL START UP

5.1 Initial Start Up

Before starting the griddle for the first time, clean the griddle body and cooking surface
with a mild soap and water solution then rinse with clear water and dry.
Set the main power switch, located at the far left of the control panel, to the "ON" (up)
position.
Set the temperature dials to 200 degrees.
Heat the griddle at 200 degrees for 2 hours to evaporate any moisture that may be in the
elements.
After 2 hours at 200 degrees, proceed with "SEASON THE COOKING SURFACE".

5.2 Season the Grill

The cooking surface must be "seasoned" in order to reduce product sticking.
To season, heat the griddle to 250 degrees.
Once at 250 degrees, coat the cooking surface with a non-salted vegetable oil.
Allow the griddle to stand at 250 degrees until the cooking surface looks dry then coat it
again.
Heat the griddle to 350 degrees and repeat the procedure.

The griddle may emit a small amount of smoke as the cooking surface passes the
350

°

 point.  Do not be alarmed as oils associated with the manufacturing process

may cause smoke and will stop when the griddle reaches 350 degrees.

Содержание Cruise CLG-36B-S

Страница 1: ...y 6500 Merrill Creek Parkway Everett WA 98203 Phone 425 349 2400 Fax 425 349 2733 WWW LANGWORLD COM Copyright 2000 Installation Operation Maintenance Troubleshooting Model CLG 36B S Electric Cruise Li...

Страница 2: ...NING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALL...

Страница 3: ...APTER PAGE 1 TABLE OF CONTENTS 3 2 READ FIRST 4 3 UNPACKING 6 4 INSTALLATION 7 5 INITIAL START UP 8 6 OPERATION 9 7 CLEANING 10 8 TROUBLESHOOTING 11 9 PARTS LIST 13 10 EXPLODED VIEWS 14 11 WIRING DIAG...

Страница 4: ...PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The d...

Страница 5: ...this or any other LANG appliance must be performed by qualified personnel only Consult your authorized service station directory or call the factory at 1 800 224 LANG 5264 or WWW LANGWORLD COM for th...

Страница 6: ...r its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways 3 3 Un crating The griddle will ar...

Страница 7: ...nstallation of any components such as a vent hood grease extractors fire extinguisher systems must conform to their applicable National State and locally recognized installation standards 4 1 Electric...

Страница 8: ...at 200 degrees proceed with SEASON THE COOKING SURFACE 5 2 Season the Grill The cooking surface must be seasoned in order to reduce product sticking To season heat the griddle to 250 degrees Once at...

Страница 9: ...ch cooking section If product is loaded directly over the temperature sensor that section will turn on and the element will heat the entire cooking section If the product is loaded to the side front o...

Страница 10: ...ove the grease drawer after each meal and wash the inside and outside of the drawer Keep the griddle surface clean After each cooking load scrape the griddle surface with the grooved griddle cleaning...

Страница 11: ...to the Possible Cause for the items to be checked To test for a possible cause refer to the TEST section and locate the Possible Cause then refer to test to identify test procedures SYMPTOM POSSIBLE...

Страница 12: ...PARTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY If an item on the list is followed by an asterisk the work should be done by a factory authorized service representative Possible Cause TEST Pr...

Страница 13: ...3 15 Element Box LGCL 725 16 Snap Bushing 1 3 8 SB1375 16 Black 70801 02 2 17 Electric Box Cover LGCL 524 1 18 Element Griddle 440 Volt 5991 Watts 11030 48 3 19 Nut Hex Stainless Steel 10 32 20303 02...

Страница 14: ...14 EXPLODED VIEW...

Страница 15: ...15 EXPLODED VIEW CONT D...

Страница 16: ...16 EXPLODED VIEW CONT D...

Страница 17: ...17 EXPLODED VIEW CONT D...

Страница 18: ...18 WIRING DIAGRAM...

Страница 19: ...ted by the repair Quartz elements are warranted for ninety 90 days from the date of installation II Damage during shipment is to be reported to the carrier is not covered under this warranty and is th...

Отзывы: