GENERAL INSTALLATION DATA (continued)
PILOT LIGHTING INSTRUCTIONS
The charbroiler is equipped with an automatic pilot/ignter with an electronic spark.
Be sure all gas control knobs on the units front panel are turned OFF.
Turn on main gas supply valve to unit.
Turn "ON" the switch on front control panel to activate electonic pilot lighter.
The pilot igniter tubes on this broiler have been pre-set at the factory. Turn the adjustable screw
counterclockwise to open and clockwise to close.
Adjust pilot light flames, if necessary as small as possible, usually about 3/8" high, but high
enough to light burner immediately when burner valve is turned on high.
Turn burner knobs to desired setting.
To turn burners off, turn knobs off and turn off switch on front control panel.
BURNER IGNITION AND ADJUSTMENT
To ignite burners turn burner valve knob counter clockwise to "ON"position.
Slowly decrease openings of air shutters to give a soft blue flame having luminous tips, then
slowly increase openings to a point where the yellow tips disappear and a hard blue flame is
obtained.
DO NOT ATTEMPT TO OPERATE UNIT DURING A POWER FAILURE.