                 SPECIFICATIONS

This product conforms to the requirements of the following European Regulations, Directives & Rules:

CE Mark (93/68/EEC), Low Voltage (72/23/EEC), EMC (2004/108/EEC), 

RoHS (2011/65/EU), WEEE (EU2002/96/EC)

In order to reduce environmental damage, at the end of its useful life, this product must not be disposed of along with normal 

household waste to landfill sites.  It must be taken to an approved recycling centre according to the recommendations of the 

WEEE (Waste Electrical and Electronic Equipment) directive applicable in your country.

9

Supply Voltage 

~100V, ~120V, ~220V, ~230V, ~240V 50/60Hz Factory Option

Mains Fuse 

~220V>~240V = T1A L.   ~100>~120V = T2A L

Power Consumption 

220W

Output Power Rating 

120W

Loudspeakers 

2 Custom Designed 12" Drivers

Features 

TEC Tube Emulating Technology

 

XTS eXtreme Tone Shaping 

  

(Drive channel only)

 

Speaker socket 

 

(Minimum 8 Ohm Impedance)

 

AUX IN (10K Input impedance) 

(Nominal 750mV Input level)

 

FX Loop 

 

(Nominal 750mV Level)

 

Footswitchable  

 

 Yes, Channel and FX  (FS2 Not Included)

Reverb 

Yes

EQ 

Both channels contain separate Passive Bass, Middle and Treble

Input Impedance 

1MOhm/47pF

Size 

479*680*275 (H*W*D)

Unit Weight 

22.7 Kg     (Shipping Weight  24.2 Kg)

BLOCK DIAGRAM

INPUT

POWER
AMP

CD IN

DRIVE

CLEAN

XTS

REVERB

FOOTSWITCH

EQ SECTION

EQ SECTION

POWER

 AMP IN

This loop is a series type 

so all of your signal will go 

through your FX unit.

PREAMP

OUT

FX

RETURN

FX

SEND

INTERNAL

LOUDSPEAKERS

EXTERNAL

LOUDSPEAKER

Содержание LX 120RTwin

Страница 1: ......

Страница 2: ...ug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 Never break off the ground pin Connect only to a power supply of the type marked on the unit adjacent to the power supply cord 16 If this product is to be mounted in an equipment rack rear support should be provided 17 N...

Страница 3: ...ler votre unité Celle ci doit être contrôlée si elle a subit des dommages de manipulation d utilisation ou de stockage humidité 15 Ne déconnectez jamais la prise de terre de votre unité 16 Si votre unité est destinée a etre montée en rack des supports arriere doivent etre utilises 17 Note pour les Royaumes Unis Si les couleurs de connecteurs du cable d alimentation ne correspond pas au guide de la...

Страница 4: ...chnitte 14 Lassen Sie sämtliche Wartungsarbeiten von qualifizierten Kundendiensttechnikern durchführen Eine Wartung ist erforderlich wenn das Gerät in irgendeiner Art beschädigt wurde etwa wenn das Netzkabel oder der Netzstecker beschädigt wurden Flüssigkeit oder Gegenstände in das Gerät gelangt sind das Gerät Regen oder Feuchtigkeit ausgesetzt wurde nicht normal rbeitet oder heruntergefallen ist ...

Страница 5: ...le de alimentación o el enchufe se han dañado algún líquido ha sido derramado o algún objeto ha caído dentro del aparato el aparato ha sido expuesto a la lluvia o la humedad no funciona de manera normal o ha sufrido una caída 15 Nunca retire la patilla de Tierra Conecte el aparato sólo a una fuente de alimentación del tipo marcado al lado del cable de alimentación 16 Si este producto va a ser enra...

Страница 6: ...6 ...

Страница 7: ... Fuse 220V 240V T1A L 100 120V T2A L Power Consumption 220W Output Power Rating 120W Loudspeakers 2 Custom Designed 12 Drivers Features TEC Tube Emulating Technology XTS eXtreme Tone Shaping Drive channel only Speaker socket Minimum 8 Ohm Impedance AUX IN 10K Input impedance Nominal 750mV Input level FX Loop Nominal 750mV Level Footswitchable Yes Channel and FX FS2 Not Included Reverb Yes EQ Both ...

Страница 8: ...8 ...

Страница 9: ...our custom XTS technology It also features an extension speaker socket to drive additional cabinets and an AUX IN socket should you need to play along to a CD MP3 FX loop sockets for your external FX processors and finally the LX120RTwin features a built in reverb with master level control An explanation of these features follows on pages 10 11 We hope you enjoy using your LX120RTwin as much as we...

Страница 10: ...e overall volume with 9 Indicates that the drive channel is active Controls the crunch channel gain low down for classic rock and blues higher up for hard rock and metal the higher you go the more Extreme it gets Use in conjunction with 9 to get the overall level balanced how you want it Controls the overall level on the drive channel Use with 8 eXtreme Tone Shaping This applies a scooped mid tone...

Страница 11: ...CORRECT SIZE AND RATING OF FUSE AS SPECIFIED ON THE PANEL See specs section on page 7 Displays the model number power requirements and serial number of the unit Connect an extension loudspeaker cabinet here the internal loudspeaker is left connected The impedance of the extension cabinet must not be less than 8 Ohms Connecting cabinets that have a lower impedance than 8 Ohms will result in the amp...

Страница 12: ...QUICK START SETTINGS Suggestions only experiment CLEAN SETTINGS BLUES SETTINGS IN OUT IN IN IN ROCK SETTINGS EXTREME METAL SETTINGS 12 ...

Страница 13: ...Found some settings you like store them here 13 ...

Страница 14: ...W Program Serial Number Input Laney Power To The Music www laney co uk DESIGNED IN THE UK BY LANEY 8 Ohms Link Model RB115 Power Rating 300W Program Serial Number Input Laney Power To The Music www laney co uk DESIGNED IN THE UK BY LANEY LX412A L Z B 1 2 3 4 FX Controller ...

Страница 15: ...olume controls on your guitar amplifier and then turn off its power before turning off other equipment Cables never use shielded or microphone cable for any speaker connections as this will not be substantial enough to handle the amplifier load and could cause damage to your amplifier system Caution These professional loudspeaker systems are capable of generating very high sound pressure levels Us...

Страница 16: ...OPERATING INSTRUCTIONS 1 1 ...

Отзывы: