background image

9

Содержание LV300

Страница 1: ...300H 300TWIN 300 ...

Страница 2: ...als in your plug proceed as follows a The wire that is coloured green and yellow must be connected to the terminal that is marked by the letter E the earth symbol coloured green or coloured green and yellow b The wire that is coloured blue must be connected to the terminal that is marked with the letter N or the colour black c The wire that is coloured brown must be connected to the terminal that ...

Страница 3: ...e manipulation d utilisation ou de stockage humidité 15 Ne déconnectez jamais la prise de terre de votre unité 16 Si votre unité est destinée a etre montée en rack des supports arriere doivent etre utilises 17 Note pour les Royaumes Unis Si les couleurs de connecteurs du cable d alimentation ne correspond pas au guide de la prise secteur procédez comme suit a Le connecteur vert et jaune doit être ...

Страница 4: ...ttechnikern durchführen Eine Wartung ist erforderlich wenn das Gerät in irgendeiner Art beschädigt wurde etwa wenn das Netzkabel oder der Netzstecker beschädigt wurden Flüssigkeit oder Gegenstände in das Gerät gelangt sind das Gerät Regen oder Feuchtigkeit ausgesetzt wurde nicht normal rbeitet oder heruntergefallen ist 15 Der Erdungsstift darf nie entfernt werden Schließen Sie nur an die Stromvers...

Страница 5: ...ún objeto ha caído dentro del aparato el aparato ha sido expuesto a la lluvia o la humedad no funciona de manera normal o ha sufrido una caída 15 Nunca retire la patilla de Tierra Conecte el aparato sólo a una fuente de alimentación del tipo marcado al lado del cable de alimentación 16 Si este producto va a ser enracado con más equipo use algún tipo de apoyo trasero 17 Nota para el Reino Unido sol...

Страница 6: ...warnen die von Ausrichender Starke sind um einen elektrischen Schlag verursachen zu konnen Intended to alert the user of the presence of important operating and maintenance Servicing instructions in the literature accompanying the product Dieses Symbol soll den Anwender vor unsolierten gefahrlichen Spannungen innerhalb des Gehauses warnen die von Ausrichender Starke sind um einen elektrischen Schl...

Страница 7: ...17 4Kg 19 3Kg LV412A 18 2Kg 20 5Kg LV412A Recommended Ex Cabinet Size Yes Yes Unit Weight Top Handle Supply Voltage on all models Factory Preset 1M Ohm 47pF T5A L T2A L 300W 120W 12 Custom Designed Driver Rugged Construction T5A L T2A L Footswitchable Cannels Reverb Clean Bright Switch 1M Ohm 47pF Yes Nominal 750mV Level Series Insert Input Impedance FX Loop Ex Loudspeaker Socket 2 x 12 Custom Des...

Страница 8: ... LOUDSPEAKER INTERNAL LOUDSPEAKERS INPUT POWER AMP DRIVE1 CLEAN DRIVE1 SCOOP REVERB EQ SECTION EQ SECTION EXT LOUDSPEAKER EXT LOUDSPEAKER FX RETURN This loop is a series type so all of your signal will go through your FX unit FX SEND DRIVE2 DRIVE1 SCOOP ECC83 TUBE STAGE DRIVE REVERB CLEAN REVERB VTS POWER ON MUTE FOOTSWITCH BRIGHT In the interest of continued development Laney reserves the right t...

Страница 9: ...9 ...

Страница 10: ...d an overall VTS tone shaping switch The built in reverb has independent level controls for the clean and drive channels and is footswitchable with the enclosed three way footswitch as are the clean and drive channels They also feature an extension speaker socket to drive additional cabinets and a global FX Loop for any external effects units The LV300 is loaded with a single 12 Custom loudspeaker...

Страница 11: ... level before being shipped to our customers We hope you enjoy using your new LV300 whichever model you choose as much as we enjoyed designing and making it It should give you years of trouble free service however please take time to read this manual as it will allow you to get the best from your model Best wishes from all at Laney ou ll want your playing to be heard That s why we amplify the soun...

Страница 12: ... 0 0 0 0 5 5 5 5 5 5 5 5 5 5 5 5 5 8 8 8 8 8 8 8 8 8 8 8 8 8 2 2 2 2 2 2 2 2 2 2 2 2 2 I POWER 0 INPUT BASS TREBLE GAIN GAIN BRIGHT MASTER MASTER BASS MIDDLE CLEAN TREBLE DRIVE MIDDLE VOLUME DRIVE 2 DRIVE EQUALISATION REVERB CLEAN CHANNEL DRIVE 1 300 TUBE FUSION 300H 300 300TWIN 8 12 3 3 3 1 2 4 6 9 5 7 11 10 16 17 18 19 20 21 13 14 15 22 This socket should be used for connecting your instrument t...

Страница 13: ...lume control Setting low levels of gain with high levels of volume will result in a nice crisp blue sy lead tone Setting the gain control to midway with a medium volume level will give you a punchy hard rock lead tone and setting the gain to maximum and backing the volume off gives you a full on metal lead tone Obviously the type of guitar you use will have an effect on the overall sound you hear ...

Страница 14: ... an extension loudspeaker cabinet here the internal loudspeaker remains connected The impedance of the extension cabinet must not be less than 8 Ohms 4 Ohms on the Head Connecting cabinets that have a lower impedance will result in the amplifier overheating Line level FX Loop Return to connect back from an external effects controller Line level FX Loop Send to connect to an external effects contro...

Страница 15: ...t surges at turn on and off which can cause damage to your speakers By turning on your guitar amplifier LAST and making sure its Volume controls are set to minimum any transients from other equipment will not reach your loudspeakers Wait until all system parts have stabilised usually a couple of seconds Similarly when turning off your system always turn down the Volume controls on your guitar ampl...

Страница 16: ...pedance of the cabinet s must not be less than 8 Ohms Connecting cabinets that have a lower impedance than 4 Ohms will result in the amplifier overheating and may cause permanent damage Permitted configurations could be 1x8 Ohm 2x8 Ohm or 2x16 Ohm cabinets FX Controller 300 300TWIN 115V 220V 230V 16 ...

Страница 17: ... not be less than 4 Ohms Connecting cabinets that have a lower impedance than 4 Ohms will result in the amplifier overheating and may cause permanent damage Permitted configurations could be 1x4 Ohm 1x8 Ohm 2x8 Ohm or 2x16 Ohm cabinets FX Controller 300H 17 115V 220V 230V ...

Страница 18: ...CLEAN DRIVE MIDDLE VOLUME CLEAN CHANNEL DRIVE 1 DRIVE 2 DRIVE EQUALISATION REVERB 7 7 7 7 7 7 7 7 7 7 7 7 7 1 1 1 1 1 1 1 1 1 1 1 1 1 9 9 9 9 9 9 9 9 9 9 9 9 9 3 3 3 3 3 3 3 3 3 3 3 3 3 10 10 10 10 10 10 10 10 10 10 10 10 10 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 0 0 0 0 0 0 0 0 0 0 0 0 0 5 5 5 5 5 5 5 5 5 5 5 5 5 8 8 8 8 8 8 8 8 8 8 8 8 8 2 2 2 2 2 2 2 2 2 2 2 2 2 I POWER 0 INPUT BAS...

Страница 19: ...NOTES 19 ...

Страница 20: ...OPERATING INSTRUCTIONS Issue 1 1 ...