Laney Alliance VH100R Скачать руководство пользователя страница 9

CAUTION

RISK OF ELECTRIC SHOCK DO NOT OPEN

SUPPLY VOLTAGE

HT FUSE

CAUTION

TO REDUCE THE RISK OF FIRE REPLACE 

ONLY WITH SAME TYPE AND RATING

MODEL   

SERIAL NO.

1*16 OHM

MAXIMUM POWER CONSUMPTION

300 WATTS

WARNING - THIS APPARATUS MUST BE EARTHED

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,

DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT 

REMOVE COVER. NO USER SERVICABLE PARTS INSIDE. REFER 

SERVICING TO QUALIFIED SERVICE PERSONEL.

ATTENTION REMPLACER LE FUSIBLE PR LE MEME 

ET CALIBRE

ATTENTION DEBRACHER A LA PRISE SECTEUR AVANT D’OUVRIR

MADE IN THE U.K.

www.laney.co.uk

Laney

Power To The Music

T1A L

MAINS FUSE

~220-240V = T2A L 250V

~100-120V = T5A L 250V

1*8 OHM

1*4 OHM

2*16 OHM

2*8 OHM

L

OUDSPEAKERS

WARNING:

USE ONLY ONE IMPEDANCE

SELECTION AT A TIME

CLASS 2 WIRING MAY BE USED

IN

OUT

LINE

PREAMP

POWERAMP

FOOTSWITCH EL34

6L6/

5881

BIAS

ONLY FOR USE

WITH LANEY FS4

INSERT

RETURN

LEVEL

RETURN

SEND

BYPASS

SIDE/

CHAIN

INSERT

SEND

RETURN

RETURN

RETURN

EFFECTS LOOP

EFFECTS LOOP

OVERDRIVE CHANNEL B

CLEAN CHANNEL A

A+B

SEND

0

10

POWER INLET SOCKET:

  Connect to your power source.  Make sure the specified voltage is correct for your country!  

POWER FUSE:

 This is the main safety fuse for the unit.  The fuse protects the AC power to the amplifier.  USE ONLY THE 

CORRECT SIZE AND RATING OF FUSE AS SPECIFIED ON THE PANEL.  If a fuse blows or fails and a replacement of the 
same size and rating is installed and it in turn blows, the amplifier has suffered a malfunction internally and needs immediate 
service from a qualified technician.  DO NOT TRY USING A FUSE OF HIGHER RATING.  Using a fuse that is too large in 
current rating may cause serious, irreparable damage to the amplifier and presents a serious fire hazard.  The mains fuse 
ratings are detailed in the specs section at the rear of this manual

HT FUSE: 

 This fuse protects the DC power to the tubes within the amplifier.  USE ONLY THE CORRECT SIZE AND 

RATING FUSE AS SPECIFIED ON THE PANEL.  If a fuse blows or fails and a replacement of the same size and rating is 
installed and it in turn blows, the amplifier has suffered a malfunction, at this point check the output tubes and replace faulty 
ones if required.  Should tubes not be the problem the amplifier should be checked out by a qualified technician.  Do not try 
using a fuse of greater value.  Using a fuse that is too large in current rating may cause serious, irreparable damage to the 
amplifier.  Fuses are designed to protect, do not take chances. 

LOUDSPEAKERS:

 Loudspeaker outlets are provided on a series of five 

 

 jack sockets.  The impedance of the 

loudspeaker/s should be checked and connected to the appropriate socket/s.  Using the incorrect sockets will reduce the life 
of your output tubes and won’t sound as good and in extreme cases could damage your amplifier. 

IMPORTANT:

 Operation of your VH100R amplifier without a loudspeaker connected could result in expensive failure of 

your output transformer.  

DO NOT OPERATE WITHOUT A LOUDSPEAKER CONNECTED. 

  There are dedicated 

optimised outputs for the following loudspeaker combinations:  1*16 ohm, 1*8 ohm, 2*16 ohm, 1*4 ohm, 2*8 ohm.

¼” (6.3mm)

Laney

                  OPERATING INSTRUCTIONS

Page 9 /20

37

37

51

51

35

35

38

38

36

36

34

34

0

V

H

1

0R

33

33

32

32

31

31

39

39

40

40

41

41

42

42

43

43

44

44

45

45

46

46

47

47

48

48

49

49

50

50

52

52

REAR PANEL CONTROLS

Содержание Alliance VH100R

Страница 1: ...100W ALL TUBE GUITAR HEAD AMPLIFIER POWER TO THE MUSIC Laney V 1 0R H 0OPERATING INSTRUCTIONS 2 2 w w w l a n e y c o u k...

Страница 2: ...aking it readily operable 15 Metal parts can be cleaned with a damp cloth The vinyl covering used on some units can be cleaned with a damp cloth or ammonia based household cleaner if necessary Disconn...

Страница 3: ...de decharge electrique ou de feu n exposez pas cet appareil a la pluie ou a l humidite Avant d utiliser cet appareil lisez les advertissments supplentaires situes dans le guide VORSICHT VORSICHT ACHT...

Страница 4: ...heck the number with the explanations adjacent to each panel Your Laney amplifier has undergone a thorough two stage pre delivery inspection involving actual play testing When you first receive your L...

Страница 5: ...arise yourself with the controls as it will allow you to get the best from your amplifier We hope you enjoy using yourVH100R as much as we enjoyed designing and making it Best wishes from all at Laney...

Страница 6: ...hy from high gain humbucker type pickups Also use this input for the cleanest full range sound with extended low end response Only use good quality guitar cable GAIN Sets the level of tube preamplifie...

Страница 7: ...loud the built in reverb sounds The reverb in theVH100R is a legendary Sound Enhancements aka Accutronics Reverb The only choice for that authentic reverb sound There are separate controls for Channel...

Страница 8: ...gh level on the Gain control and a low setting on theVolume will give you a punchy hard rock lead tone with the ability to again drive the output tubes at higherVolume settings Having set the Gain and...

Страница 9: ...d technician DO NOT TRY USING A FUSE OF HIGHER RATING Using a fuse that is too large in current rating may cause serious irreparable damage to the amplifier and presents a serious fire hazard The main...

Страница 10: ...al effects to this socket A notable feature on the VH100R is that you won t lose sustain when the FX loops are in use This is because the power stages are still driven by a tube FX loop buffer 0 VH1 0...

Страница 11: ...ffects processors It operates in sidechain mode and any external processors should be set to Effect only Mode if at all possible CHANNEL B RETURN Connect the output of the Channel B FX processor here...

Страница 12: ...Laney OPERATING INSTRUCTIONS QUICK START SETTINGS 0 VH1 0R Ultra Clean Clean Crunch Grungy Punk Rock Rhythm Page 12 20...

Страница 13: ...S These settings are suggestions only and will obviously vary depending on your guitar and playing style Experiment until you find something you like Page 13 20 0 VH1 0R Blues Lead Rock Lead Metal Lea...

Страница 14: ...highs or lows and low level hum The Output tubes can be replaced singularly if you replace them with the exact same type AND grade as factory fitted otherwise they should be replaced as a set If the s...

Страница 15: ...C83 Standard 2nd Gain Stage Clean Ch V5 ECC83 Standard 3rd Gain Stage Drive Ch V6 ECC83 Standard Power Driver Stage V7 10 EL34B STR MATCHED SET EL34B Grade Number EL34B Grade Number Laney OPERATING IN...

Страница 16: ...nel CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN SUPPLY VOLTAGE HT FUSE CAUTION TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATING MODEL SERIAL NO 1 16 OHM MAXIMUM POWER CONSUMPTION 300 W...

Страница 17: ...ETURN SEND BYPASS SIDE CHAIN INSERT SEND RETURN RETURN RETURN EFFECTS LOOP EFFECTS LOOP OVERDRIVE CHANNEL B CLEAN CHANNEL A A B SEND 0 10 8 Ohms Link Model RB115 Power Rating 300W Program Model RB115...

Страница 18: ...1 8 Ohm 2 8 Ohm 1 4 Ohm BIAS RESONANCE PRESENCE V8 V10 BRIGHT BRIGHT PAD PAD CLEAN VOLUME V3b V4b BRIGHT BRIGHT DRIVE V5a VOLUME V1a CLEAN CHANNEL DRIVE CHANNEL GAIN V2a V1b DRIVE V2b V5b EQ EQ BASS M...

Страница 19: ...n and Drive Resonance Switch Bright Switch For Clean Channel Clean Drive Presence Footswitchable Channel Drive A Drive B Reverb Laney FS4 footswitch included Input Impedance 1MOhm 47pF Size Unit Weigh...

Страница 20: ...oduct development Laney Reserves the right to amend product specification without prior notification POWER TO THE MUSIC Laney JAZZ AMPICONS ARE HERE TO HELP BLUES ROCK METAL w w w l a n e y c o u k LA...

Отзывы: