5.4.2 Transport
Transport of devices packed in the factory should be done in the following conditions:
Table 11. Environmental parameters for transport
Environmental parameter
Permissible value
Ambient temperature
-40
÷
+80
°
C
Speed of temperature change
≤
10
°
C/h
Maximum air humidity
95%
Air-pressure
700
÷
1060 hPa
Multiple Strokes
5
÷
15 g at the period of 10 ms
5.5 Electromagnetic Compatibility
The devices meet the requirements of class A devices relating to radio-electric
interference emission, as described in the PN-EN 55022 standard:
under the condition that
they are installed in accordance with this instruction.
Caution:
The device is of class A. In living conditions it may cause radio-electric
interferences. In such cases you can demand taking proper remedial
measures.
5.6 Power Supply
Table 12. Power supply parameters
Parameter
or feature
Parameter value or
feature description
Nominal power voltage
0 Hz; 6
÷
60 V
Current consumption at 6 V DC voltage
500 mA
Current consumption at 60 V DC voltage
45 mA
Types of connectors
triple screw clamp connector
5.7 Product Components
All TR-55 product components delivered to the Customer include:
1. TR-55 converter
1 item
2. IO-55-x operation manual
1 item
3. Warranty certificate