Landtek HT-6510S-A Скачать руководство пользователя страница 1

AVE

N

5-1

5-2

5-3

5-4

5-5

5-6

5-7

5-8

5-9

5-10
5-11

5-12

HT-6510S-A

HT-6510S-B

HT-6510S-C

SAND MOULD 

SURFACE HARDNESS 

TESTER

2.   FEATURES

*  The  Sand  Mould  Surface  Hardness  Tester  is 

used  to  measure  the  surface  hardness  of  the 
sand  mould/core  of  the  wet  mold  and  provide 
technical parameters for the formulation of the 
molding process.

*  The  surface  hardness  of  sand  mold  is  divided 

into  three  types:  A,  B  and  C,  The  common 
model is type B, among them:
Type A:  Suitable  for  the  surface  hardness  test 

o f  f i n e  s a n d  m o l d / c o r e  i n  m a n u a l  o r 
m e c h a n i c a l  l o w  a n d  m e d i u m  p r e s s u r e 
molding.

Type  B:  Suitable  for  the  surface  hardness  test 

of fine and coarse sand mold/core in manual 
or  mechanical  low  and  medium  pressure 
molding.

Type  C:  Suitable  for  the  surface  hardness  test 

of sand mold in high pressure molding.

*  The  unit  of  type  B  hardness  tester  for  sand 

2

mold surface is (g/mm ), but it is customary to 

use  hardness  H(A/B/C)  instead  of  unit. 
B e c a u s e  t h e i r  v a l u e s  a r e  r e l a t e d  a n d 
consistent, the corresponding hardness value is 

2

also large when the unit value is large (g/mm ).

* Low voltage indicator.
*  Digital    display    gives    exact  reading  with    no 

guessing or errors.

*  Can  communicate  with  PC  for  recording, 

printing    and    analysing    by    the    optional 
software and cable for RS232C interface. 

* Automatic power off to conserve power. 

3. WORKING PRINCIPLE

According to the principle that the force on the 
spring  is  linear  with  the  stroke,  the  stroke  is 
converted into a value through the sensor.
The unit of surface hardness of molding sand B 

2

is (g/mm ), but it is customary to indicate it in 
terms of hardness H(A/B/C) instead of unit.
Because  their  quantities  are  related  and 
consistent,  the  corresponding  degree  value  is 

2

also large when the unit value is large (g/mm ).

4.   SPECIFICATIONS

Display: 4

 

digits, 10 mm LCD

Display Range: 0~100 H(A/B/C)
Measurement Range: 10~90 H(A/B/C)
Resolution: 0.1 H(A/B/C)
Measurement deviation: 

≤ ±1

H(A/B/C)

Internal parameters:

It has the function of peak value latch, average 
value calculation and under voltage alarm.
PC interface: RS232C interface
Power supply: 2x1.5v AA (UM-3) battery
Operating condition: Temp. 0~40˚C
                                       Humidity <80% 
Size: 162x65x28mm (6.4x2.6x1.1inch)
Weight: about  170g
                               (not including batteries)

Power off:  2 modes

        

Manual off at any time by depressing the

          power key till OFF shows on the display 
          or Auto power off after 2 minutes from 
          last key operation. 
Accessories: 
              Carrying case .............1 pc.
              Operation manual .........1 pc.
Optional accessory:
                   Cable and software for RS232C

4.  FRONT PANEL DESCRIPTIONS

5-1 Sensor                 
5-2 Display
5-3 Power  key
5-4 Max hold key
5-5 Zero key
5-6 N/Average key
5-7 RS232C interface

5-8 CAL key
5-9 Indicator of  Max.Value
5-10 Indicator of Average value 
5-11 State of average value
5-12 Number of measurements 
in the state of average value

6.   MEASURING PROCEDURE

6.1 Test specimen 

The  minimum  thickness  is  specified  in  a 
different  standard,  see  part  1.  Specimen 
should allow measurement to be taken at least 
12  mm  from  any  edge.      Specimen  surface 
should  be  flat  and  parallel  to  allow  the   
presser    face    to    contact    to    the  specimen 
over  an  area  which  has  a  minimum  radius  of 
6mm from the durometer probe. The specimen 
may  be  constructed  with  layered  pieces  to 
a c h i e v e   t h e   n e c e s s a r y   t h i c k n e s s  
requirements,  however  measurements  taken 
on these specimens may not  agree with those 
made  on  solid  specimens,  due  to  the  surface 
faces  between  layers  not    being  in  complete 
contact.

6.2 Depress and release the “Power key” to power 

the tester on.

6.3  Depress  the  “MAX”  key  till  the  mark  MAX   

shows on the display.

6.4  Hold  the  durometer  vertically  with  the  point 

of the indenter at least 12 mm from any edge. 
Apply  the  presser  foot  to  the  specimen  as 
rapidly  as  possible,  without  shock,  keeping 
the  foot  parallel  to  the  surface  of  the 
specimen.  Apply  just  sufficient  force  to 
obtain  firm  contact  between  the  presser  foot 
and the specimen. Hold for 1 or 2 seconds, the 
maximum  reading    can    be    obtained 
automatically.  

6.5  To  take  the  next  measurement,  just  depress 

the  “Zero  key”  and  repeat  6.4.  On  the  other 
hand, you can depress the “Max hold key” till 
the  mark  MAX  disappears  from  the  display.   
And then repeat the step 6.3 and 6.4.

6.6  If  other  than  a  maximum  reading  is  needed, 

no  need  to  set  the  mark  “MAX”  showing  on 
the  display.  In  such  case,  the  reading  on  the 
display  is  an  instant  value.  Just  hold  the 
durometer  in  place  without  motion  and 
obtain  the  reading  after  the  required  time 
interval (Normally less than 1 second) .

6.7  How to take average  value
6.7.1 To take the average value of many times of 

measurements,  just  depress  and  release    the 
“N/AVE  key”  to  make  the  symbol  “N”   
showing  on  the  display,  followed  by  a  digit   

1. SELECTION GUIDE

Hardness Range

between  1-9  with  the  prefix  “No.”  .    Here 
the digit is the times of measurements  used 
to  calculate  the  average  value.  Every    time 
depress  and  release  the  “N/AVE  key”,  the 
digit  will  increase  1.  And  the  digit  will 
become  “1” while  depressing  the “N/AVE 
key” at “9” .

6.7.2    Adjust  the  digit  to  the  number  needed 

and  depress  “MAX  key”  or  “Zero  key”  to 
return  to  the  measurement  state  or  wait  for 
several seconds till “0” on the display. 

6.7.3 Take measurements as per steps from  6.3 

to  6.5.  Be  sure  that  every  test  should  be  6 
mm  apart.  Every  time  take  a  measurement, 
the  reading  and  the  times  of  measurements 
show  on  the  display.  When  the  times  of 
measurements is equal to the number set, the 
unit  first  displays  the  reading  of  the  last  , 
and  then  display  the  average  value  of  last 
“N”  measurements,  followed  by  2  beeps, 
with  a  symbol  “AVE”  indicating  on  the 
display.

6.7.4 To take the next average value, just repeat 

6.7.3. 

6.7.5 To release from average measurement, just 

depress the “N/AVE” till “N” disappears.

7.   CALIBRATION CHECK

A Type used for Fine Sand Mould

B Type used for Fine & Coarse Sand Mould

C Type

low                         middle                         high

Model

A

B

C

Stroke
Load
Pressure Load
Shape and size 
of indenter

2.50mm
237g
90g
Spherical 
R2.50

2.50mm
980g
50g
Spherical 
R12.70

2.50mm
1500g
180g
Spherical 
R1.20

Отзывы: