OPERATING INSTRUCTIONS
3-21
Hydraulic Power Supply
Engine Operation (Option)
1. The Hydraulic Power Supply Engine system is used
to power the hydraulic functions, should the tractor
not be equipped with hydraulic hookups.
IMPORTANT
1. Check the following fluids before starting the
engine package: engine oil, fuel supply, hydraulic
oil. (Check oil level while semitrailer is not tilted.
If semitrailer is tilted, the oil level in the tank will
not read accurately.)
2. If the engine does not crank, check the following
on the battery: charge fluid, terminals, and
cables. Take corrective actions as needed.
CAUTION
2. The Engine Ignition Switch
is located below the
hydraulic controls, and behind them on the driver’s
side of the semitrailer
Use the key
to start and stop the Hydraulic Power Supply Engine.
This switch has three positions:
Table 3-7: Engine Ignition Switch
3. The Hydraulic Power Supply Engine Throttle is
located to the right on the driver’s side of the
semitrailer
The Engine Throttle
controls the speed at which the engine operates.
It is
a variable position control
Table 3-8: Hydraulic Power Supply Engine Throttle
4. To start, set the throttle to the
(MEDIUM IDLE)
position.
5. Turn the ignition key to the START position. The
engine should crank and then start.
CAUTION
6. When the engine starts, release the key.
7. To adjust the speed, turn the throttle control in or out,
as needed, until the engine runs smoothly at a speed
capable of withstanding use of the hydraulic controls.
The hydraulic controls should now be functional.
8. Before shutting it off, allow the engine to cool down
by running at a slow idle for thirty seconds.
9. Once the engine is cool, turn or push the throttle
completely in and turn the ignition switch key to the
OFF
position.
If the hydraulic fluid level is low during operation,
the semitrailer may not operate correctly,
resulting in damage to the semitrailer.
ENGINE IGNITION SWITCH
OFF
In this position, the power package
engine does not run. The key can only
be inserted or removed from this
position.
RUN
In this position, the engine runs without
activating the starter.
START
In this position, the starter cranks the
power package engine, to start it. After
the engine is started, release the key to
the RUN position.
HYDRAULIC POWER SUPPLY ENGINE THROTTLE
FULL OUT
In this position, the engine throttle is
fully open, letting it run at full speed.
FULL IN
In this position, the engine throttle is
closed, letting the engine run at a slow
idle.
Do not crank engine for more than 10 seconds. If
engine does not start, consult the owner’s
manual supplied with the engine.