4-32
F-1013-1118
MAINTENANCE AND LUBRICATION
Stabilizer Leg Counter Balance
Valve
1.
Remove lock valve as described in
(See
2.
Remove retaining plug
.)
3.
Remove o-ring plug opposite retaining plug on
rectangular block.
4.
Using a drift small enough to fit through the port
opened in the previous step, tap out the lock valve
cartridges.
5.
Install new lock valve cartridges back to back (as
illustrated). Grease o-rings.
6.
Install two new o-rings and two back-up washers on
retaining plug.
7.
Thread retaining plug into body (tap gently to engage
threads). Torque plug to 15 ft.lbs.
8.
Install new o-ring on plug, opposite retaining plug.
Thread plug into body. Torque to 70 in.lbs.
9.
Replace spring and poppet. Replace the o-ring on
plug and reinstall.
10. Install new o-rings and back-up washers on top of
piston rod.
11. Thread lock valve on piston rod until firmly seated. If
the ports need to be relocated, loosen the screw at
the top of the well tube and turn lock valve clockwise
until ports are at the desired location. Retighten the
set screw.
Figure 4-25: Stabilizer Leg Counter Balance Assembly
STABILIZER LEG
COUNTER BALANCE VALVE
RETAINING PLUG
BACKUP
WASHER O-RING
COUNTER
BALANCE VALVE
SIDE SECTION
FRONT SECTION
FRONT SECTION
REMOVE PLUG TO INSTALL ORIFICE
SPRING
POPPET
PLUG
TOP SECTION