5-2
F-1099-2021
TROUBLESHOOTING GUIDE
HYDRAULIC - WING SETTLING
Wing cylinder leaking
Repair cylinder.
COULTER GANG PLUGGING
Operating depth too deep
Raise unit.
Conditions too wet
Wait until conditions more favorable.
COULTER GANG WILL NOT TURN OR
PUSHES SOIL
Depth set too deep for loose or wet
conditions
Raise implement or wait until conditions
are more favorable
Gang bearing failure
Replace bearing
COULTER BLADES LOOSE AND/OR
SHEARING ROLL PIN
Gang not tightened properly
Retighten gang shafts to 1200-1500 ft.-lbs.
If gangs have ran loose, gangs may
require disassembly to remove soil to
properly torque gang shafts. Replace
any worn components, shafts/spools,
etc.
PROBLEM
PROBABLE CAUSE
SOLUTION