TROUBLESHOOTING (CONT'D)
SPECIFICATIONS
ISSUE
POSSIBLE CAUSE
SOLUTION
Frost is forming in the
refrigerator.
The environment is humid.
Through the unit uses an “auto defrost” system, under
certain conditions, manual defrosting may be required.
If frost builds up, you can try running the refrigerator on
a warmer temperature setting, minimizing the number of
times you open the door, or unplugging the unit to allow
the frost to melt.
The ambient temperature is too low.
The door is being opened too frequently.
The door will not shut
properly.
The refrigerator is not level.
Make sure the refrigerator is on a level surface.
The door gasket is dirty.
Clean the door gasket.
The door gasket is not installed correctly.
Make sure the door gasket is properly installed.
The shelves are incorrectly installed.
Install the shelves correctly.
Description
24 Inch Single Zone Undercounter Refrigerator
Model
L3024UI1***
Color
Panel Ready
Voltage/Frequency
115V AC / 60 Hertz
Amperage
1.5 Amps
Refrigerant
R600a, 40 grams / 1.4 Oz
Unit Dimensions
(H x W x D)
34" x 23 13/16" x 23 1/4"
NOTE
Technical data and performance information are provided for reference only. Specifications are subject to change. Check the rating
label on the refrigerator for the most accurate information.