Installation Safety Precautions
Grill installation must conform with local codes, or
in their absence with
National Fuel Gas Code,
NFPA 54/ ANSI Z223.1
. Grill is not for use in or on
recreational vehicles and/ or boats.
All electrical accessories (such as rotisserie) must
be electrically grounded in accordance with local
codes, or
National Electrical Code, ANSI/NFPA
70.
Keep any electrical cords and / or fuel supply
hoses away from any hot surfaces.
This grill is safety certified for use in the United
States only. Do not modify for use in any other
location. Modification will result in a safety hazard.
Natural Gas Connections and Service Regulators
Above 1/2 psi.
Prior to 1998, all residual gas service regulators
were set with an outlet pressure of 7 inches water
column.
In the 1998 edition of NFPA54, the National Fuel
Gas Code, a change was made allowing serive
regulators of 2 and 5 psi.
With this change it was also required that an in
line regulator be connected between the service
regulator and the appliance regulator if the 2 or 5
psi system is used. This additional regulator is not
supplied with the product.
It is possible for a consumer, making the
connection themselves, or a plumber, not
checking, to tap into a 2 or 5 psi line. If a pressure
of 2 psi or greater is supplied to the appliance
regulator on certain grills it will shut down and not
deliver any gas to the grill. Other concerns are the
quick disconnect socket and hose which are only
rated to 1/2 psi.
If the quick disconnect socket, hose, and grill are
properly connected and still not getting gas,
delivery pressure needs to be verified. If pressure
is greater than 1/2 psi, make sure that an in line
regulator is present.
Once the grill has been over-pressured, the
regulator may or may not have been damaged.
Thhe best practice is to replace the regulator.
Gas Conversion
32
This
appliance
is
set to
operate
at
1/2psi
water
column supply pressure.
Verify supply pressure with
your local gas company. If
supply pressure is different
than this, contact a certified
plumber for assistance.
Incorrect connection can result
in a gas leak with possibility of
fire.
For residential use only. Do
not use for commercial
applications
Содержание 43100
Страница 20: ...Gas Connections 20 Semi rigid gas connector CSA Approved Gas Regulator Gas Supply Shutoff Valve ...
Страница 37: ...37 Replacement Parts Models 43100 43101 ...
Страница 38: ...38 Replacement Parts Models 43100 43101 ...
Страница 39: ...Replacement Parts Models 43102 43103 39 ...
Страница 40: ...40 Replacement Parts Models 43102 43103 ...
Страница 41: ...Replacement Parts Models 43104 43105 41 ...
Страница 42: ...42 Replacement Parts Models 43104 43105 ...