Display / priority rating
18/39
8
Display / priority rating
The view is limited to up to 7 entries. At pulse parameterization, the display
will adapt automatically.
The display resolution can be selected from the following:
Pulse Energy
Energy
Volume
Flow
Power
[l/p]
[MWh]
[GJ]
[m³]
[m³/h]
[kW]
1
0000.001 0000.001 00000.01 000.001 00000.1
2.5
0000.001 00000.01 00000.01 000.001 00000.1
10
00000.01 00000.01 000000.1 000.001 00000.1
25
00000.01 000000.1 000000.1 000.001 00000.1
100
000000.1 000000.1 0000001
0000.01 000001
250
000000.1 0000001
0000001
0000.01 000001
1.000 000000.1 0000001
0000001
0000.01 000001
2.500 000000.1 0000001
0000001
0000.01 000001
Note: Calculators up to 2.5 l/p can be parameterized to kWh. Cal-
culators up to 1 l/p can be parameterized to MJ.
The pulse values are restricted by following connecting conditions:
Pulse Max. power Max. flow
[l/p]
[MW]
[m³/h]
1
3.3
24
2.5
3.3
24
10
33
240
25
33
240
100
330
2400
250
330
2400
1.000 330
2400
2.500 330
2400
9
Power supply
The calculator can be supplied with power via a battery supply modules as
preferred. Battery and power supply are replaceable at any time.
Options:
•
6 years battery
•
11 years battery
•
16 years battery
•
Power supply 230 V AC
•
Power supply 110 V AC
•
Power supply 24 V ACDC
Automatic power supply detection
The power supply detects whether a line voltage is applied. This signal is
routed to the calculator. That enables the device to detect automatically
whether it is being powered from a battery or power supply.