Power supply
24/49
8
Power supply
The meter can be supplied with power via a battery or via power supply mod-
ules as preferred. Battery and power supply are replaceable at any time.
Options:
6 years battery
11 years battery
16 years battery
Power supply 230 V AC
*)
Power supply 110 V AC
*)
Power supply 24 V ACDC
*) From 2018 replaced by a wide-range power supply 100 - 240V
Automatic power supply detection
The power supply detects whether a line voltage is applied. This signal is
routed to the meter. That enables the device to detect automatically whether it
is being powered from a battery or power supply.
Power supply requirements
Requirements
(for measuring timebase Q = 4
s and time base T = 30 s)
6
years
11
years
16
years
Power supply
(230, 110 V
AC; 24 V
ACDC)
Standard pulses,
M-Bus read out
(max. each
15 min.)
, CL-Module
2x AA
C
D
yes
Radio module 868 MHz
(mo-
bile radio; 16 sec. transmis-
sion interval)
D
D
--
yes
Radio module 868 MHz
(sta-
tionary radio; 15 min. trans-
mission interval)
D
D
D
yes
M-Bus fast read out
(max.
each 4 sec.)
, fast pulses,
analog module
D
--
--
yes
Fast measurement raster
(for measuring timebase Q =4
s and time base T = 4 s)
D
--
--
yes
Note:
The lifetime of battery depends on the type of battery and on
the requirements.
Note:
Only batteries approved by the manufacturer may be in-
stalled.