Communication
22/36
Voltage drop
0.9 V at 30 mA (OB) / 0.1 V at 0.1 mA (OC)
Output connection
9.2
M-Bus module
Note:
The data scope of the readout can be parametrized via Ul-
taAssist.
The M-Bus module is used to communicate the meter with an M-Bus central
unit for the wireless transmission of measured values.
All meter data can also be read out via the M-Bus interface.
Standard
EN 13757-2
Conformity
OMS
Separation/Connec-
tion
Galvanically coupled
Power consumption
Max. 1 M-Bus load (1.5 mA)
Addressing meter
Primary or secondary
Addressing pulse in-
puts
Primary or secondary
Readout frequency
300 Bd and 2400 Bd with automatic baud rate
detection
9.3
Radio Module 868 MHz (Wireless M-Bus)
The wireless M-Bus function enables the meter to communicate with a station-
ary unit or a mobile unit using 868 MHz radio frequency.
The module supports the OMS
1
-compliant data transfer including an individual
encryption function.
Содержание T450
Страница 3: ...Contents 3 36 ...
Страница 31: ...Log functions 31 36 P14 Pulse output parameterization P15 M Bus parameterization P16 wM Bus parameterization ...
Страница 35: ...Pressure loss weight and dimension of package 35 36 Flow rate in m h Pressure loss in mbar ...