Landis+Gyr 2WR5 Скачать руководство пользователя страница 2

         
Ultrasonic heat meter 2WR5 

Operating instructions 

UH 302-101l 

Seite 2 / 3 

Service loop 1 („LOOP 1“)  

 

Current flowrate 

 

 

Current heat output 

 

 

Current flow and return temperature 

 

 

Threshold value for the tariff, e.g. T

V

 

 

 

Property number, 7-digit 

 

 

Date  

 

Annual set day (dd.mm) *) 

 

 

Heat for previous year on set  day *) 

 

 

Tariff register for previous year on set day *) 

 

 

Volume for previous year on set day *) 

 

 

Version of firmware 

 

*) see comment about the yearly set day on page 3

 

Service loop 2 („LOOP 2“)

 

In service loop 2 the 

monthly values

 are displayed. 

One of the previous 36 monthly values can be 
selected by pressing the button briefly. The corres-
ponding data are then opened by pressing the 
button for 3s. Each time the button is pressed briefly 
the next value for the selected month is displayed.  

 

Set day previous month Sep. 2004 

 

Set day previous month Aug. 2004 

...

 

Set day previous month xxxx 200y 

 

pressing the button for more than 3s: 

Ø

 

 

Qty of thermal energy on this set day 

 

Tariff register on this set day, e.g. cold 

 

Volume on this set day 

 
 

Max. flowrate in Jul. 2004, 
changing with date stamp every 2s 

 
 

Maximum heat output in Jul., 
changing with date stamp every 2s 

 
 
 

Max. temperatures in Jul., 
changing with date stamps of flow and 
return every 2s 

 

Status of missing time counter on this set 
day 

After the last item is shown, the current set day is 
again displayed. The next set day can be selected 
by pressing the button briefly. 

Service loop 3 („LOOP 3“)

 

 

Parameter of fast pulses,  
significance of energy pulses 

 

Significance of volume pulses 

 

Pulse length in ms 

 

Interval of temperature measurement 

 

Date stamp for F0 warning 

 

Type of built in module 

 

M-bus primary address **) 

 

M-bus secondary address **) 

**) only shown if module is of type MB 

Note: Standard time used inside the meter is the 
central europe time (CET). 

Monthly values 

The calculator stores for 36 months at the set day at 
00:00h the values of 
- Heat (meter reading) 
- Tariff (register reading) 
- Volume (reading) 
- Max. flowrate (monthly maximum averaged   
  across the measurement period, standard    
  60 min), with date stamp 
- Max. demand (monthly maximum averaged 

  

  across the measuring period), with date stamp 
- Max. temperatures (monthly maximum) with date 
  stamp each for flow and return 
- Missing hour counter (reading) 
The monthly values can also be read out via the 
optical and 20 mA interface. 

Error codes 

The heat meter performs self-diagnostics 
continuously and can thus display various errors.  

Error message 

F0

 means there is air in the volume 

measurement part and it is necessary to vent the 
heating system thoroughly. Error message 

F4 

means the battery needs replacing. 

Error messages 

F1

F2

 or 

F5

F6, F8

 mean the 

sensor is defective. 

F3

F7

F9

 indicated a fault in 

the electronics. In all these cases, you must contact 
service. 