background image

 

 

en 

Installation Instructions 

 

Calculator 
ULTRAHEAT

®

T550 

(UC

50…) 

ULTRACOLD

®

T550 

(UC50

…)

 

 

08.05.2017 

Translation 

 

T550 

(UC50…)

 

 

Gyr GmbH 

Subject to change without prior notice 

08.05.2017 

 

Note:

 In the following text, the term calculator refers to 

both  heat  meter  calculator  and  cooling  meter  calcula-
tor, unless they are otherwise differentiated. 

1. 

General 

The  calculator  left  the  factory  in  a  faultless  condition  where 
safety  is  concerned.  Adjustments,  maintenance  work,  re-
placement  of  parts or repairs may only be carried out by spe-
cialist  staffs  who  are  aware  of  the  associated  hazards.  The 
manufacturer  will  provide  additional  technical  support  on  re-
quest.  Calibration  relevant  security  seals  on  the  calculator 
must  not  be  damaged  or  removed.  Otherwise  the  guarantee 
and calibration validity of the meter will lapse. 

 

Keep the packaging so that you can transport the calcula-
tor in its original packaging following expiry of the calibra-
tion validity. 

 

Lay all cables at a minimum distance of 500 mm to high 
voltage and high frequency cables. 

 

A relative humidity of < 93 % at 25 °C is permissible (with-
out condensation). 

 

The 110 V / 230 V network parts correspond to protection 
rating II so that the line voltage does not need to be dis-
connected when changing the meter. 

2. 

Safety Information 

 

The  calculator  may  only  be  used  in  building  service 
engineering  systems  and  only  for  the  applications 
described. 

 

The  local  regulations  (installation  etc.)  must  be  ad-
hered to. 

 

Adhere  to  the  operating  conditions  according  to  the 
dial plate during use. Non-adherence can cause haz-
ards and the guarantee will lapse. 

 

Guarantee  and  calibration  validity  will  lapse  if  the 
calibration relevant security seals are broken. 

 

Only  clean  the  calculator  from  outside  with  a  soft, 
lightly  wetted  cloth.  Do  not  use  any  spirit  or  cleaning 
solvent. 

 

The 110 V / 230 V connections may only be made by 
an electrician. 

 

The  calculator  may  only  be  powered  up  once  the 
installation has been completed. There is otherwise a 
danger of electronic shock on the terminals.  
A defective or obviously damaged appliance must be 
disconnected from the power supply immediately and 
replaced. 

 

As  far  as  disposal  is  concerned,  the  calculator  is  a 
waste  electronic  appliance  in  the  sense  of  European 
Directive  2012/19/EU  (WEEE)  and  it  must  not  be 
disposed of as domestic waste. The relevant national, 
legal  regulations  must  be  observed  as  the  appliance 
must be disposed of via the channels provided for this 
purpose. The local and currently valid legislation must 
be observed. 

 

The  calculator  may  contain  lithium  batteries.  Do  not 
dispose  of  the  calculator  and  the  batteries  with  do-
mestic waste. Observe the local stipulations and laws 
on disposal. 

 

You  can  return  the  lithium  batteries  to  the  manufac-
turer  for  appropriate  disposal  following  use.  When 
shipping  please  observe  legal  regulations,  in  particu-
lar,  those  governing  the  labelling  and  packaging  of 
hazardous goods. 

 

Do not open the batteries. Do not bring batteries into 
contact  with  water  or  expose  to  temperatures  above 
80 °C. 

 

The calculator does not have any lightning protection. 
Ensure  lightning  protection  via  the  in-house  installa-
tion. 

 

Only fit one compartment for the power supply. Do not 
remove the red locking hatch. 

3. 

Installation 

 

Note:

  The 

mounting  place

  and  the 

pulse  value

  of 

flow  sensors  with  pulse  output  must  correspond  to 
the in the calculator set values (see LOOP 2). 

 

Service loop 

2 („LOOP 2“) 

Service loop 2 displays the installation details.  

 

Head of the loop

 

 

Mounting place of the flow sensor: cold side or 

 

Mounting place of the flow sensor: hot side

 

 

Pulse value

 

 

 

Note:

  At  a 

heat  meter  calculator

  or  combined 

heat/cold  meter  calculator  the  mounting  place  of  the 
flow  sensor  cold  side  is  equivalent  to  return.  The 
mounting place of the flow sensor hot side is equiva-
lent to flow. 

 

Note: 

At  a 

cooling  meter  calculator

  the  mounting 

place of the flow sensor hot side is equivalent to the 
return.  The  mounting  place  of  the  flow  sensor  cold 
side is equivalent to flow. 

 

Attention: 

Calculators  with  one-time  adjustable 

pulse value and adaptable mounting place being  

characterized by: 

 

 

Attention: 

At  calculators  with  one-time  adjustable 

pulse value, the pulse value must be adjusted during 
commissioning  in  accordance  with  the  flow  sensor 
and the mounting place must be checked! 

As  long  as  the  pulse  value  has  not  been  set,  the 
calculator does not cumulated energy and volume. 

The  mounting  place  can  be  adapted  and  is  fully 
locked by entering the pulse value. 

 
 
 
 
 
 

3

2

 1

9

 1

0

1

 0

0

2

 b

 

Содержание ULTRAHEAT T550

Страница 1: ...d As far as disposal is concerned the calculator is a waste electronic appliance in the sense of European Directive 2012 19 EU WEEE and it must not be disposed of as domestic waste The relevant national legal regulations must be observed as the appliance must be disposed of via the channels provided for this purpose The local and currently valid legislation must be observed The calculator may cont...

Страница 2: ...erature sensors into the pockets ball valves or T pieces The end of the temperature sensors must reach at least to the centre of the pipe cross section Seal the temperature sensors to protect against manipula tion Put the housing cover in position and press it gently until all the lugs click into place audibly 3 2 Connection of flow sensor Note The flow sensor must be installed at the same circuit...

Страница 3: ...and press it gently until all the lugs click into place audibly Installing power supply module Note The 110 V 230 V connections may only be made by an electrician To install a power supply module proceed as follows Move the red locking hatch to the left Move the right outside rubber sleeve upwards and out wards Pull the sealing plug Thread the module s mains voltage connetion cable through the sle...

Страница 4: ...n modules Note You will find the technical details and data on communication modules in their documentation Note You will find the permitted combinations in the T550 UC50 technical description Note The meter recognises the inserted modules automatically 30 seconds at most after installation and is ready for communications or pulse output Note The type of module inserted can be displayed within the...

Страница 5: ...t To close the parameterisation proceeds as follows Press the service button during parameterisation ESC function The LCD display shows the last valid value 4 9 Service software With the service software tariffs and communication modules can be set in parameterisation mode 5 Getting started Attention Calculators with one time adjustable pulse value and adaptable mounting place being characterized ...

Страница 6: ...ary in exchange with F1 Interruption in the hot side tempera ture sensor Check hot side temperature sensors replace if necessary F2 Interruption in the cold side tem perature sensor Check cold side temperature sensors replace if necessary F3 Electronics for temperature evalua tion defective Exchange the calculator F4 Problem with the power supply Battery flat Check connection Change battery F5 Sho...