S15

Place of installation, supply

S17

Meter type: Heat meters or combined

heat/cooling meters

S18

Meter type: Cooling meter

S21

Current flow rate

S22

Error message

S23

Power supply: Mains

S24-S26

Power supply: Battery with capacity

indicator

S27

Module identifier

S28

Current loop display (LOOP)

S29-S32

Tariff display

13-15

Current display code (LCD-ID)

3.3 Display current meter reading

The meter displays the current meter reading in kWh, MWh, MJ

or GJ.

Note

To avoid reading errors, the decimal places of displayed

values are marked by a frame.

Note

The calibrated value is indicated by an additionally

displayed star symbol (S12).

Note

Depending on the device parameterisation, both the

display scope and the displayed data may deviate from this

description.

3.3.1 Display values

The meter displays are arranged in multiple loops (LOOPs). The

default state is LOOP 0.

Proceed as follows to switch between the LOOPs:

Press button 2 until the desired LOOP appears.

After the last loop LOOP LE, LOOP 0 is displayed again.

3.3.2 Advancing in a loop

To advance to the next display value within a loop, proceed as

follows:

Press button 1.

After the last display value, the first display value appears again.

3.3.3 Loop "LOOP 0"

The meter is in loop "LOOP 0".

Press button 1 to advance to the next display value.
The LCD displays the following values one after the other:

Table 1: Loop "LOOP 0"

Loop head

Error message

(here: currently no

error)

Current energy

quantity (here:

kWh; heat meter;

installation location:

Return flow; tariff

on)

Current volume

Current value tariff

register 1 (only if

tariff was selected)

Current value tariff

register 2 (only if

tariff was selected)

Current value tariff

register 3 (only if

tariff was selected)

Segment test

Firmware version

CRC/CMAC

© Gyr

Subject to change without prior notice

07.02.2020

3

Содержание T450

Страница 1: ...esponds to the supply In the case of a cooling meter the warm side installation location corresponds to the return and the cold side installation location to the supply 2 Safety instructions Caution The meters may only be used in building installations and only for the applications described Caution The local regulations installation etc must be observed Caution The operating conditions on the nam...

Страница 2: ...he meter contains lithium batteries Do not dispose of the meter and batteries as household waste Observe local regulations and laws regarding disposal Warning After lithium batteries have been used you can return them to the manufacturer for proper disposal When shipping batteries please observe legal regulations which among other things govern the labelling and packaging of hazardous goods Warnin...

Страница 3: ...ranged in multiple loops LOOPs The default state is LOOP 0 Proceed as follows to switch between the LOOPs Press button 2 until the desired LOOP appears After the last loop LOOP LE LOOP 0 is displayed again 3 3 2 Advancing in a loop To advance to the next display value within a loop proceed as follows Press button 1 After the last display value the first display value appears again 3 3 3 Loop LOOP ...

Страница 4: ...e 5 55 C Housing protection class IP 54 IP 68 optional EN 60529 Response limit for ΔT 0 2 K Temperature difference ΔT 3 K 120 K Temperature measurement range 0 180 C LCD 8 digit Optical interface Standard EN 62056 21 Communication Optional e g M bus Splitability Always removable cable length optional Temperature sensor Type Pt500 or Pt100 EN 60751 Temperature range 0 150 C up to 45 mm overall leng...

Страница 5: ...6 Declaration of conformity Landis Gyr GmbH Humboldstrasse 64 90459 Nuremberg Germany Landis Gyr Subject to change without prior notice 07 02 2020 5 ...

Отзывы: