Alle Angaben verstehen sich als unverbindliche Richtwerte! Für nicht schriftlich bestätigte Datenauswahl übernehmen wir keine Haftung. Druckangaben beziehen sich, soweit nicht anders angegeben, auf Flüssigkeiten der Gruppe II bei +20°C.
6
Dokumentation
VORTEX-Rohre
MAIL:
TEL:
(05 61) 9 58 85 - 9 ·
FAX:
(05 61) 9 58 85 - 20
All VORTEX 14 KP are fitted with a strong magnet allowing it to be fitted to any surface that will hold the magnet. The magnet can be removed by unscrewing the
hot end silencer and removing the nut holding the magnet in place.
9.5 Installation
The large VORTEX 14 KP has a ¼” BSP female air fitting.
Standard Pneumatic push-fit compressed air fittings can be used on the VORTEX 14 KP.
Air Fitting
9.6 Operation
All VORTEX 14 KP are set to deliver the most efficient cooling possible. VORTEX 14 KP are factory set to 70% cold fraction at 80psi (5.4 Bar). As standard they are
fitted with a Red 15 cfm Generator, so approximaty 10cfm of cold air will exit through the cold end of the VORTEX 14 KP.
VORTEX 14 KP
The Cold fraction is the percentage of input compressed air that is released through the cold end of the VORTEX 14 KP. The Cold Fraction is adjusted in two ways,
by adjusting the control relief valve to exhaust more or less air (Adjustable version only) or by changing the generator inside the VORTEX 14 KP.
There are two levels of Generator, either a “high” or “low” cold fraction model. A “high” cold fraction Generator is where more than 50% of the air flow exits
through the cold end of the VORTEX 14 KP. This setting will suit most industrial applications as it provides the most efficient cooling, although not the coldest possi-
ble temperature.
A “low” cold fraction Generator is where less than 50% of the air flow exits through the cold end of the VORTEX 14 KP. This setting will provide the lowest air tem-
peratures but will not be as efficient.
Cold Fraction
The VORTEX 14 KP is supplied with a set of 4 high fraction Generators as standard.
Yellow 10cfm (283 l/min)
Red 15cfm (425 l/min)
Blue 25cfm (708 l/min)
Brown 35cfm (991 l/min)
The Generators within the VORTEX 14 KP control the air consumption and air flow, they also influence the achievable temperatures.
To change the Generator, simply unscrew the cold end silencer (the end the knuckle trunking is fitted to).
Generators
You will then need to remove the cold cap from the Vortex Tube. You can simply unscrew this from the VORTEX 14 KP. Inside you will find an O’ring and Generator.