background image

OPERATOR’S MANUAL

For technical assistance or the dealer nearest you,  

consult our web page at 

www.landa.com

    

 

ENG4-2000 

  

 

ENG4-2200 

 

ENG4-3000 

 

    

 

ENG5-2300 

  

 

ENG5-3000 

 

ENG6-3200 

    

 

ENG8-3200 

  

 

ENG10-3000 

ENG

LISTED

®

9.801-511.0 

98015100-1

GR

OU

ND

8

10

12

14

16

0

2


6

TACH/HOU

R

TACH/HOU

R

1. 

Pla

ce 

all 

sw

itches

 in 

the

 “O

FF

” p

osi

tion

.

2. 

Connec

t  p

ow

er 

sup

ply

  to

  pr

ope

rly 

gro

und

ed 

outlet.

  Te

st 

the

  G

FC

I (if

 eq

uip

ped

) usi

ng 

the

 re

set

 an

d tes

t pr

oce

dur

es 

pro

vid

ed 

on 

the

 GF

CI 

devi

ce.

 Th

e G

FC

I m

ust

 be

 re

set

 an

test

ed 

wit

h e

ver

y u

se.

3. 

Se

cur

e h

igh

 pr

ess

ure

 ho

se,

 sh

ut-

off 

gun

 an

d w

and

 to

 ou

t-

let 

4. 

Co

nne

ct w

ate

r su

ppl

y h

ose

 an

d tu

rn 

on 

wa

ter.

 

5. 

Gra

sp 

wa

nd 

 Pl

ace

 pu

mp

 sw

itch

 in 

the

 “ON”

 po

siti

on.

6. 

Tur

n g

as 

val

ve 

con

tro

l kn

ob 

to “ON

” position.

 Pi

lot 

wil

l light

 

automatically

 wh

en 

bur

ner

 sw

itch

 is t

urn

ed 

“ON”

.

7. 

To 

hea

t w

ate

r, p

lac

e b

urn

er 

sw

itch

 in 

the

 “ON

” po

siti

on 

and

 

adj

ust

 the

rm

ost

at to

 desired

 tem

per

atu

re.

8. 

Tur

n o

n d

ete

rge

nt a

nd 

pro

cee

d w

ith 

cle

ani

ng.

9. 

Aft

er 

cle

ani

ng:

 

A. 

Tur

n o

ff d

ete

rge

nt a

nd 

rin

se.

 

B. 

Pla

ce 

bur

ner

 sw

itch

 in th

e “

OF

F” 

pos

itio

n.

 

C. 

 Allo

w machin

e to

 dis

cha

rge

 wa

ter

 for

 2-

3 m

inu

tes

 to 

  

cool coi

l.

 

D. 

Pla

ce 

pump 

sw

itch

 in th

e “

OF

F” 

pos

itio

n.

 

E. 

 Sq

uee

ze tr

igg

er 

gun

 to 

reli

eve

 system p

ressu

re.

 

F.  

Tur

n o

ff w

ate

r su

ppl

y.

MODE D’E

MPLOI

LIR

E L

E M

AN

UE

L D

E L

’OP

ER

AT

EU

R A

VANT 

UTI

LIS

ATION

 UN

E  

MA

UV

AIS

E U

TIL

ISA

TION

 PE

UT

 CA

USER

 DE

S B

LESSUR

ES

 OU

 

DO

MM

AGE

S MA

RIE

LS

INS

TR

UC

CIO

NE

S D

E O

PE

RA

CIO

N

LEA E

L M

ANU

AL

 DE

 OP

ER

AC

IÓN

 AN

TE

S D

E U

SA

RS

E. 

 LA

 OP

ER

AC

IÓN

 

INA

DE

CU

AD

A PUE

DE

 OC

AS

ION

AR

 LE

SIO

NE

S PERSONALE

S O 

DA

ÑO

A  

LAS 

PR

OP

IED

AD

ES

OPER

ATI

NG

 IN

ST

RU

CTION

S

RE

AD

 OP

ER

ATI

NG 

MA

NU

AL

 BE

FOR

E O

PE

RA

TIN

G M

AC

HIN

E. 

IMP

RO

PE

R O

PE

RA

TION

 MA

Y R

ES

UL

T IN

 PE

RS

ON

AL

 IN

JU

RY

 OR

 

PR

OP

ER

TY

 DA

MA

GE

.

1. 

Co

loqu

e to

dos

 los

 interr

upt

ore

s e

n la

 pos

ició

n “

OF

F” 

(AP

AG

AD

O)

.

2. 

Co

nec

te l

a fu

ent

e d

e e

ner

gía

 a u

n to

ma

cor

riente 

con

ect

ado

 a t

ierr

a d

e m

odo

 ad

-

ecu

ado

. P

rue

be 

el Interr

upt

or 

Ac

cio

nad

o p

or 

Co

rrie

nte

 de

 Pérdid

a a

 Tie

rra

 (GFC

por

 su

s s

igla

s e

n I

ngl

és)

 (s

i h

ubi

era

) m

edi

ant

e l

os 

pro

ced

imi

ent

os 

de 

rein

icio

 y 

pru

eba

 inc

orp

ora

dos

 en

 dic

ho 

dis

pos

itiv

o. E

l G

FC

I d

ebe

 rei

nic

iars

e y 

pon

ers

e a

 

pru

eba

 ca

da 

vez

 qu

e s

e u

se.

3. 

As

egu

re 

la m

ang

uer

a d

e a

lta 

pre

sió

n, 

pis

tola

 y 

var

illa

 al 

aco

pla

dor

 de

l to

ma

cor

-

rie

nte

.

4. 

Co

nec

te l

a m

ang

uer

a d

e suministro

 de

 ag

ua 

y a

bra

 la 

llav

e.

5. 

Su

jete

 

 la

 va

rilla

. C

olo

que

 el

 interr

upt

or 

de 

la 

bomba

 en

 la

 posici

ón 

“ON

” (E

NC

EN

DID

O)

.

6. 

Co

loq

ue 

la p

eri

lla 

de 

con

tro

l de

 la 

válvul

a d

e g

as 

en 

la p

osi

ció

n “

ON

” (E

NC

EN

DI-

DO

). E

l pi

loto

 se

 en

cen

der

á a

uto

tica

me

nte

 cu

and

o e

l qu

em

ado

r se

 en

cie

nda

7. 

 de

 ca

len

tar

 el 

agu

a, c

olo

que

 el 

interr

upt

or 

del

 qu

em

ado

r e

n la

 posici

ón 

“ON

” 

(EN

CE

ND

IDO

) y 

aju

ste

 el te

rm

ost

ato

 a l

a te

mp

era

tur

a d

ese

ada

.

8. 

En

cie

nda

 el 

det

erg

ent

e y

 proced

a co

n la

 limpieza.

9. 

De

spu

és 

de 

lim

pia

r:

 

A. 

Ap

agu

e e

l de

ter

gen

te y

 en

jua

gue

.

 

B. 

Po

nga

 el inter

ruptor

 de

l qu

em

ado

r e

n la

 posici

ón 

“OF

F” 

(AP

AG

AD

O).

 

C. 

De

je q

ue 

la máquin

a d

esc

arg

ue 

agu

a p

or 

2 ó

 3 m

inu

tos

 pa

ra 

que

 se

  

 en

fríe

 el 

ser

pen

tín.

 

D. 

Po

nga

 el 

inte

rru

pto

r d

e la

 bomba

 en

 la 

posici

ón 

“OF

F” 

(AP

AG

AD

O).

 

E. 

Pres

ione

 la 

pis

tola

 pa

ra aliviar 

la p

res

ión

 de

l sistema.

 

F. 

Cier

re 

el sum

inistro

 de

 ag

ua.

1. 

Mette

z to

us 

les

 inte

rru

pte

urs

 en

 po

siti

on 

“OF

F”.

2. 

Connec

tez

 le 

blo

c d’ali

mentation 

éle

ctr

iqu

e à

 un

e p

rise 

cor

rec

tem

ent

 

mis

e à

 la 

ter

re. 

Tes

tez

 le 

dis

jon

cte

ur 

de 

fuit

e d

e t

err

e (

le ca

s é

ché

ant

à l

’aid

e d

es 

pro

céd

ure

s d

e r

éin

itia

lisa

tion

 et

 d’es

sai

 in

diq

uée

s su

r le

 

dis

jon

cte

ur. 

Le 

dis

jon

cte

ur 

doi

t ê

tre

 ré

init

iali

sé 

et 

test

é à

 ch

aqu

e utili

-

sat

ion

.

3. 

Fix

ez 

le tu

yau

 à h

aut

e pressio

n, l

e p

isto

let 

et l

e tu

be 

rig

ide

 au

 ra

ccor

de so

rtie

.

4. 

Co

nne

cte

z le

 tuy

au 

à e

au 

et f

aite

s c

oul

er l’

eau

.

5. 

Ten

ez 

le t

ube

 rig

ide

 fer

me

me

nt. 

Mette

z l’i

nter

rupteu

r d

e la

 pompe

 en

 

posi

tion

 “ON”

.

6. 

Tou

rne

z le

 bo

uto

n d

u r

obi

net

 de

 ga

z e

n pos

itio

n “

ON

”.  

La 

veilleus

s’allume

 au

tom

atiq

uem

ent

 lor

squ

e l’i

nterr

upt

eur

 du

 brû

leu

r es

t m

is su

“ON”

.

7. 

Po

ur 

cha

uffe

r l’e

au,

 me

ttez

 l’interr

upt

eur

 du

 br

ûle

ur 

sur

 “ON

” et

 ré

gle

le t

her

mo

sta

t à 

la t

em

pér

atu

re 

vou

lue

.

8. 

Act

ive

z le

 dé

ter

gen

t et

 co

mm

enc

ez 

le n

etto

yag

e.

9. 

Ap

rès le

 ne

ttoy

age

 :

 

A. 

Co

upe

z le

 dé

ter

gen

t et

 rin

cez

.

 

B. 

Me

ttez

 l’int

err

upte

ur 

du brûle

ur su

r “OFF

”.

 

C. 

Lai

sse

z la

 ma

chi

ne 

éva

cue

r l’e

au 

pen

dan

t 2 

à 3

 mi

nut

es,

 le 

 

 tem

ps 

que

 la 

bob

ine

 refroidiss

e.

 

D. 

Mettez l’i

nterr

upte

ur 

de 

la pompe

 su

r “O

FF

”.

 

E. 

Ac

tion

nez

 le 

pis

tole

t po

ur 

réd

uire

 la pressio

n d

u s

ystèm

e.

 

F. 

Co

upe

z l’

eau

.

WA

RN

ING

PREC

AU

CIO

N / 

AV

ER

TISSEMEN

T

TO

 REDUC

E TH

E RI

SK 

OF

 IN

JUR

Y REA

OPER

AT

OR

’S 

MANU

AL

 

CA

RE

FUL

LY 

BE

FO

RE

 

US

ING

. THI

S MA

CH

INE

 

TO

 BE

 USED

 ON

LY BY

 

QU

ALIFIED 

OP

ER

AT

OR

S.

LE

A EL

 MA

NU

AL

 OP

ER

ACION

 ANTE

DE

 US

ARSE

. EST

E E

QU

IPO

 DEBE

 SE

US

ADO

 SO

LAMENT

E PO

R OPER

A-

DORES 

CAL

IFI

CADOS

.

LIR

E LE

 MA

NU

EL

 DE

 L’OPERA

TEU

AV

AN

T U

TIL

ISA

TION

. C

ET

 AP

PAR

EIL

 

DO

IT 

ET

RE

 UT

ILIS

E P

AR

 DE

S O

PE

RA

-

TE

UR

S Q

UA

LIF

IES

.

RIS

K O

F I

NJ

UR

Y—

 

PR

OT

EC

TIV

E EY

E-

WE

AR

 AND

 CL

OT

HIN

MUST 

BE 

WO

RN

wh

en

 op

era

ting

 th

is 

ma

chi

ne.

PR

OT

EJ

AS

E LO

S O

JOS

 CU-

AND

O s

e o

pe

re 

est

e e

qu

ipo

.

DE

S LUNETT

ES

 DE

 SE

CUR

ITE

 

DO

IVE

NT

 ETR

E PO

RT

EE

S 

lorsqu

e v

ou

s o

pe

rez

 ce

t a

pp

are

il.

RIS

K O

F  

AS

PHYXI

ATIO

N. 

 Us

on

ly in

 we

ll v

en

ti-

late

d a

rea

.

RIE

SGO

 DE

 AS

FIX

IA.

 Us

e e

pro

du

cto

 en

 un

 area de

 ve

nti-

lación

 adec

ua

da.

RIS

QUE

 D’

AS

PHY

XIE

. Util

iser

 

da

ns 

un

 endroi

t bien

 aéré

.

RIS

K O

F  

EL

EC

TR

OC

UTIO

N. 

Con

nec

t on

ly t

pro

pe

rly 

gro

un

de

d o

utle

t. K

ee

p all c

on

-

ne

ctio

ns 

dry

 an

d o

ff t

he

 gr

ou

nd

. K

ee

spr

ay 

aw

ay 

fro

ele

ctr

ical 

wir

ing

 an

com

po

ne

nts

. Di

sco

nne

ct from 

elect

rica

supp

ly b

efo

re 

ser

vic

ing

.

RIE

SG

O D

E E

LE

CT

RO

CU

CIÓ

N — 

Co

-

ne

cte

 el 

en

chu

fe en un contacto ad

ecua

do.

 

Man

teng

a toda

s la

s c

on

ne

cci

on

es 

sec

as 

y a

rrib

a de

l su

elo

. No

 ro

cie

 componente

eléctr

ico

s. D

esc

on

ect

e la

 

cor

rie

nte

 eléctr

ica

 an

tes

 de

 

da

r s

erv

icio

.

RIS

QU

D’E

LE

CT

ROCU

TIO

N 

—  Relier à 

de

s pr

ise

s a

vec

 

mise

 à 

la terre

 se

ule

me

nt. 

Tou

s le

 do

ive

nt 

êtr

ma

intenus

 se

cs 

et 

étr

e s

us-

pe

nd

us.

 No jamais projeter

 

de

 l’e

au

 su

r le

s c

om

-

po

san

tes

 et

 

 électr

ique

s. 

Couper l’alimentatation

 

électr

iqu

e a

van

t d

e fa

ire

 un

rép

ara

tion

.

RIS

K O

F I

NJ

EC

TION

 OR

 SE

-

VERE I

NJU

RY 

TO

 PERSON

S. 

 

Ke

ep

 cle

ar 

of 

no

zzl

e. 

HO

T DI

SCH

AR

GE 

FL

UID

 —

Do

 

no

t to

uch

 or

 dir

ect

 dis

cha

rge

 

strea

at 

pe

rso

ns.

RIESGO

 DE

 PENET

RA

CIÓN

 O 

LESIONES

 SEV

ER

AS A PERS

O-

NA

S. 

Manténgas

e fuera

 de

l alc

ance 

de

 boquill

a. 

DE

SCAR

GA 

DE

 AG

UA

 CALIE

NT

A AL

TA

 PR

ES

ION

 —

 No toqu

ni d

irija

 el 

 del agua a otra

persona

s.

RISQUE

 DE BLESSUR

ES

. S

e tenir 

loin

 de

s b

use

s. 

EA

U CH

AUD

E S

OU

S PRESSION 

LA

 SO

RTIE 

— 

Ne

 pa

s d

irig

er 

le j

et 

d’e

au

 vers de

s p

ers

on

ne

s.

SPR

AY

 GUN

 KI

CK

S B

ACK

 

— 

Ho

ld with

 bo

th 

ha

nd

s.

LA

 PI

ST

OL

A SE

 MUEVE 

CON

 

LA

 PR

ES

IÓN

 — 

So

ste

ng

a c

on

 las

 

dos m

an

os.

LA

 PO

IGNE

E P

IST

OLET

 RE

-

POUS

SE

 — 

Ten

ir à

 deu

x m

ain

s.

RIS

K O

F I

NJ

UR

Y—

HO

T  

SU

RF

AC

ES CA

N C

AUS

BU

RNS —

 Us

e o

nly

 

de

sig

ne

d g

rip

pin

g a

rea

s o

spr

ay 

gu

n a

nd

 wa

nd

.

SUPER

FIC

IES

 CA

LIENT

ES

 

— 

Us

e solament

e las áreas

 

ais

lad

as 

de

l gatill

o y

 la 

lan

za.

SU

RF

ACES 

CHA

UDES

 —

 

Tou

che

r seul

emen

t le

s pa

rtie

iso

lée

s d

es 

po

ign

ée

 pis

tole

ts 

et 

lan

ces

.

RIE

SG

O DE

 EX

PL

OS

ION

 —

 Us

el producto

 en

 ár

ea

s d

on

de

 el 

fueg

o llama

 se

an

 pe

rm

itidos

. N

o r

oci

liquido

RIS

QUE

 D’

EX

PL

OS

ION

 

 Utilise

au

x endroits

 où

 un

 nu

e e

st 

pe

rm

ise

. Ne

 pa

s v

apor

iser

 de

 liq

uid

es 

RISK OF

  

EX

PLO

SIO

N. 

 Op

era

te 

on

ly 

wh

ere

 op

en

 

  

or 

tor

ch 

is p

erm

itte

d.  

Do

 no

t sp

ray

 

 

liquid

s.

RIS

QUE

 

DE FE

U

 

OU

 

D

EX

PLO

SIO

N

RIESGO 

DE

 

INC

ENDI

O

 

O E

XPLOSIÓN

RIS

K OF

 FIR

E

 

OR

 

EXPLOSION

• 

Ma

c

hin

ne

ed

s

 

to

 

be

 

ins

tal

led

 

on

 

no

n-c

om

bu

stib

l

 wi

t

min

imu

cle

ara

nce

 

of

 

18

”.

  

Be

for

e

 lig

htin

g, 

sm

ell 

all

 ar

ou

nd

 th

ap

plia

nce

 

are

a

 

for

 

ga

s.

 

Be

 

sur

e

 

to

 

sm

ell

 

nex

t

 

to

 

th

 

be

cau

se

 

som

e

 

ga

is

 

he

av

ier

 

tha

n

 air

 

an

d

 w

ill

 settle

 

on

 

the

 

 

If

 

you

 sme

ll 

ga

s,

 

imm

ed

iate

l

cal

l

 

you

r

 

ga

s

 

sup

plie

r

 

for

 

ins

tru

ctio

ns

If

 

ga

s

 

sup

plie

r

 

can

 

no

t

 

be

 reac

he

d, ca

ll th

 de

par

tm

en

t.

  

Do

 no

t us

e too

ls t

o p

ush

 in 

or 

tur

n th

e g

as 

con

trol

 kn

ob.

 

If k

no

b wil

l no

t p

ush

 in 

or 

tur

n b

y h

an

d, 

cal

l a

 

 

ser

vic

e techn

icia

n. Usin

g fo

rce

 or

 att

em

ptin

g r

ep

air

 ma

res

ult 

in a

 

 or

 exp

los

ion

.

  

Sh

ou

ld 

pilo

t  o

uta

ge

  oc

cur

,  tu

rn 

con

tro

l  k

no

b  t

o  O

FF

 

po

siti

on

. W

ait 

5 m

inu

tes

 be

for

e r

elig

htin

g.

  

Do

 no

t u

se 

this

 eq

uip

me

nt 

if a

ny 

pa

rt h

as 

be

en

 un

de

wa

ter

. Im

me

dia

tely

 cal

l a

 se

rvic

e tec

hn

ician

 to

 ins

pec

for

 re

pa

ir.

  

El 

eq

uip

o d

eb

e s

er 

ins

tala

do

 so

bre

 un

 pis

o resisten

te 

al i

nce

nd

io, co

n u

n esp

aci

o libr

e d

e 1

8” 

min

imo

.

  

Antes 

de

 en

cen

de

r, o

lfat

ee

 alr

ed

ed

or 

de

l ap

ara

to p

ara

 

de

tec

tar

 ga

s. 

Esté

  se

gu

ro 

de

 re

visar 

cer

ca 

de

l  p

iso

po

rqu

e c

ier

tos

 ga

ses

 so

n m

ás 

pe

sad

os 

qu

e e

l ai

re. 

Si 

olfa

tea

 ga

s, a

vis

e in

me

dia

tam

en

te 

a su

 pr

ove

ed

or 

de

 

ga

s. Al

 no

 loc

aliz

ar 

el p

rov

ee

do

r, ll

am

e a

 los 

bo

mb

ero

s.

  

No

  us

e  h

err

am

ien

tas

  pa

ra 

mo

ver

  el

  co

ntr

ol 

de

l  g

as.

 

Si 

la m

an

ija 

no

 se

 pu

ed

e o

pe

rar

 co

n la

 m

an

o, 

llam

e a

 

un

 téc

nic

o c

ap

aci

tad

o. 

Fo

rza

r o

 in

ten

tar

 re

pa

rar

 es

te 

con

tro

l pu

ed

e r

esu

ltar

 en

 un

 inc

en

dio

 o 

expl

osi

ón

.

  

En

 el

 cas

o d

e a

pa

ga

rse

 el

 piloto

, a

pa

gu

e y

 es

pe

re 

min

uto

s a

nte

s d

e e

nce

nd

er.

  

No

 ut

ilic

e e

ste

 eq

uip

o e

n e

l caso

 qu

e h

ub

ier

a e

sta

do

 

sum

erg

ido

  en

  ag

ua

  pa

rcia

l  o

  to

talm

en

te 

un

  co

mp

o-

ne

nte

. C

on

sul

te 

con

 un

 té

cni

co 

de

 se

rvicio

.

  

Ne

  pa

s instal

ler

 ce

 m

ach

ine

 au

x  e

nd

roi

ts 

 il 

y a

  de

com

bus

tibl

es 

(m

êm

e le

s p

lan

che

r) d

ed

an

s u

n d

em

i-m

ètr

e.

  

Av

an

t  l’al

lum

ag

e, 

  au

tou

r  d

e  l

’ap

pa

reil

  po

ur 

de

sen

teu

rs 

de

 ga

z. 

 les

 od

eu

rs 

prè

s d

u p

lan

che

r ca

cer

tain

s g

az 

son

t pl

us 

lou

rds

 qu

e l’

air

 et 

s’a

ccu

mu

len

t su

le p

lan

che

r. Si

 vo

us 

tec

tez

 un

e o

de

ur 

de

 ga

z, a

pp

ele

imm

éd

iate

me

nt 

vot

re 

fou

rni

sse

ur 

de

  ga

z. 

Si 

cel

ui-

ci 

ne

 

pe

ut 

êtr

e jo

int,

 ap

pe

ler

 le 

pa

rte

me

nt 

de

s in

cen

die

s.

  

Ne

 pa

s u

tilise

r d’

ou

tils

 po

ur p

ou

sse

r ou

 tou

rne

r la

 so

up

ap

de 

con

trô

le d

u g

az.

 Si 

la s

ou

pa

pe 

ne 

pe

ut ê

tre

 en

fon

cée

 ou

 

tou

rné

e à

 la 

ma

in, 

ap

pe

ler 

un

 tec

hn

icie

 Fo

rce

r ou

 

ess

aye

r d

e r

ép

are

r p

eu

t ca

use

r u

n fe

u o

u u

ne

 ex

plo

sio

n.

  

Si 

le 

pilo

te 

s’é

tein

t,  t

ou

rne

r  la

  so

up

ap

e  d

e  c

on

trô

le 

en

 

po

siti

on

 OF

F. Atten

dre 

5 m

inu

tes

 av

an

t d

e r

éa

llum

er.

  

Ne

 pa

s u

tilis

er c

et é

qui

pem

ent

 si u

ne 

par

tie 

a é

té i

mm

erg

ée 

da

ns 

l’ea

u. Appe

ler 

un t

ech

nicien 

pou

r in

spe

cter cel

ui-ci

.

8.9

00

-99

0.0

CHAUD!

Содержание ENG4-2000

Страница 1: ...RN whe n ope ratin g this mac hine PRO TEJ ASE LOS OJO S CU AND O se oper e este equi po DES LUN ETT ES DE SEC URIT E DOI VEN T ETR E POR TEE S lorsq ue vous oper ez cet appa reil RIS K OF ASP HYX IA...

Страница 2: ...it means the overload is tripped Reset overload Pilot Light When the light is on it means there is power to the pilot control If there is no light see troubleshooting guide Voltage When the light is o...

Страница 3: ...5 3000 8 Installation ENG 6 3200 8 3200 10 3000 9 Installation 10 16 Assembly Instructions 17 Operating Instructions 18 Applying Detergent General Washing Techniques 19 Shutting Down Cleanup 20 Storag...

Страница 4: ...familiar with the controls 3 Stay alert watch what you are doing 4 Use only your hand to push in or turn the gas control knob Never use a tool If the knob will not push in or turn by hand don t try t...

Страница 5: ...charge stream at people or severe injury or death will result WARNING PROTECT FROM FREEZING WARNING Protect machine from freezing 13 To keep machine in best operating conditions it is importantyouprot...

Страница 6: ...RNING If connection is made to potable water supply a back flow device must be provided 27 Exhaust gases should not be vented into a wall a ceiling or a concealed space of a building A draft diverter...

Страница 7: ...IC ADO S LIRE LE MAN UEL DE L OP ERA TEU R AVA NT UTIL ISAT ION CET APP ARE IL DOIT ETR E UTIL ISE PAR DES OPE RA TEU RS QUA LIFIE S RIS K OF INJU RY PRO TEC TIVE EYE WE AR AND CLO THI NG MUS T BE WO...

Страница 8: ...Panel 19 50 Dia Customer Supplied Draft Diverter 24 00 24 87 4 00 High Pressure Out 3 8 QC Nipple 48 54 36 68 24 50 24 00 12 00 49 00 Water In 3 4 GHF 21 30 20 61 20 61 Exhaust Out 10 Dia NOTE Draft d...

Страница 9: ...to Outside Floor Mounting Dimensions 19 50 Dia Customer Supplied Draft Diverter Control Panel 61 00 17 33 34 79 17 36 26 18 3 64 High Pressure Out 3 8 QC Nipple 31 77 64 00 26 91 26 91 Water In 3 4 G...

Страница 10: ...ecommended that a partition be made be tween the wash area and machine to prevent direct spray from the spray gun from coming in contact with the machine Excess moisture reaching the power unit or ele...

Страница 11: ...ed by the Uniform Building Code Vents penetrating ceilings or walls should be double wall approved appliance vents and should be one to INSTALLATION LP Gas Liquid petroleum gas or propane LP gas is ga...

Страница 12: ...roof power venting is recommended to help eliminate exhaust restriction of this natural draft machine This draft inducer power vent must be installed by a li cenced contractor who can calculate size o...

Страница 13: ...nced by the heat created inside the coil the design of the coil and flue and the length and diameter of the exhaust stack The table below shows data included in the operator s manual for flue and stac...

Страница 14: ...4 2 wc in For an installation at 3500 feet reduce this pressure by 16 by setting the manifold pressure to 4 2 84 3 5 wc in This adjustment should only be made by a properly trained service technician...

Страница 15: ...w instructions carefully when installing or servicing machine Failure to do so may result in damage to property or personal injury 1 Installation or servicing of gas appliances and controls must only...

Страница 16: ...for the BTU rating of the burner Is incoming gas supply pressure between 6 14 water column inches or 1 2 PSIG Has the proper gas regulator been installed for pressure and volume Have you installed the...

Страница 17: ...garden hose to the cold water source Cold Water Source Garden Hose 98015100 10 STEP 6 Pull the spring loaded collar of the wand coupler back to insert pressure nozzle Release the coupler collar and p...

Страница 18: ...ent Valve STEP 4 To apply detergent open the detergent valve counterclock wise making sure that the deter gent pick up tube is in the detergent solution and not sucking air 98015100 17 NOTE High press...

Страница 19: ...thermal device prevents internal damage to the pump CLEANING TIPS Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solu tion and apply to surface For be...

Страница 20: ...syst me F Coupez l eau W ARNIN G PRE CAU CION AVE RTIS SEM ENT SK AL E NE BY ORS LEA EL MANUA L OPERA CION ANTES DE USARS E ESTE EQUIPO DEBE SER USADO SOLAM ENTE POR OPERA DORES CALIFIC ADOS LIRE LE M...

Страница 21: ...metering valve Disassemble and clean thoroughly High viscosity of detergent Dilute detergent to specifications Restriction behind float tank screen removed Install restriction Hole in detergent line s...

Страница 22: ...pair kit when needed Worn packing in pump Install new packing kit Fouled or dirty inlet or discharge valves in pump Clean inlet and discharge valve Worn inlet or discharge valves Replace with valve ki...

Страница 23: ...1 Be sure main gas valve gas cock or selector arm is turned on 2 With gas on and system sparking probe terminals PV and 24V GND If pilot gas does not flow with 24 volts at these terminals replace gas...

Страница 24: ...on With the pilot burning and the flame on the ignitor sensor rod the main burner should turn on If it does not replace the ignition control unit SHORT CYCLING OF MAIN BURNER MAIN BURNER TURNS OFF BE...

Страница 25: ...needs repairing CAUTION When using this procedure to test compo nents keep the spray gun open at all times High Limit Hot Water Thermostat For safety each machine is equipped with a high limit control...

Страница 26: ...d Exterior regulators are needed to control gas pressure Propane bottles are not included with the machine A pressure regulator should be installed between pro pane bottle and gas valve Propane Cylind...

Страница 27: ...ugh the coil by whatever means are available for the particular system the water heater is used on To Adjust Pressure Regulator Adjustment of the pressure regulator is not normally necessary since it...

Страница 28: ...per Gal Liquid 4 23 4 87 BTU per Cu Ft Vapor 2 563 3 39 BTU per Gal Liquid 91 547 102 032 BTU per Lb Liquid 21 591 21 221 Cu Ft per Lb Liquid 8 607 6 53 Cu Ft per Gal Liquid 36 45 31 8 Octane Number...

Страница 29: ...ure gauge At the lower levels it is expressed in water column inches i e 11 w c i Higher pressures are expressed in terms of the force exerted against a square inch of area for example 125 lbs per squ...

Страница 30: ...ife of your pressure washer Perform maintenance more often under severe conditions MAINTENANCE SCHEDULE Replace Fuel Lines Annually Pump Oil Inspect Daily inspect the oil level Change After first 50 h...

Страница 31: ...nter field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While not required for warranty service we request that you register your LANDA pressure washer by returning the...

Страница 32: ...Form 9 801 511 0 Revised 9 13a Printed in U S A...

Отзывы: