Landa ECOS 7000 Скачать руководство пользователя страница 15

9.801-316.0 • Landa ECOS 7000 Operator Manual • Rev. 12/12

15

 

 ECOS 7000

  

 OPERA

TOR’S MANU

AL  

98013160-33

DETERGENT INSTRUCTIONS

98013160-32

STEP 1: Connect the downstream chemical injector to 
the high pressure outlet. Route the soap line into the 
left fuel cabinet and into detergent bucket. (buckets not 
provided).

Chemical

Injector

High Pressure

Outlet

Left Fuel

Cabinet

STEP 2: Selection of high or low pressure is accompa-
nied by turning the handle.
NOTE: High pressure nozzle must be inserted at the 
wand to obtain high pressure. Variable pressure con-
trol wand handle must be turned clockwise to enable 
water to flow out of the high pressure nozzle.
To apply detergent, place detergent pick-up tube into 
a container of detergent and turn the detergent valve 
handle on the wand counterclockwise.

Brass Soap

Nozzle

Trigger

Soap Line

Variable Pressure

Control Handle

High

Pressure

Nozzle

Variable Pressure

Wand (VP)

HEAT EXCHANGER

HEAT EXCHANGER:
The incoming water temperature is raised for bet-
ter burner efficiency by the use of the systems heat 
exchanger. The heat exchanger is made up of three 
stages, these stages are engine exhausts stage, mix-
ing stage and exit stage. The hot engine exhaust is 
sent to the exchanger box where it passes thru the 
heat transfer core. The preheated water is then sent to 
the high pressure pump and exhaust gases then  exit 
the unit.

WARNING: The heat exchanger core 
becomes extremely hot and should 
not be touched while the machine is 
in operation. Allow machine to cool 
down completely before attempting 
to service this area. Always wear 
hearing protection and proper per-
sonal protection equipment when 
operating unit

 

HEAT EXCHANGER SYSTEM MAINTENANCE:
The heat exchange system in your units transfers en-
ergy between the heat of the power plant to the water 
supply of the unit. The heat transfer of this system is 
highly dependent on the surface area contact in the 
heat exchanger cores located in the heat exchanger 
box. The surface area amount is adversely minimized 

when the supplied water is not softened to recom-
mended levels (exceeds 3-1/2 grains). Hard water 
will result in scaling on the inside walls of the heat 
exchanger tubes. It is recommended that you use a 
dealer-approved water softener to avoid premature 
heat exchanger core failure. Contact your local dealer 
for advice on the water hardness levels in your area.
Additionally, the heat exchanger tubes are very sensi-
tive to freezing conditions. 

The following is recom-

mended during the cold weather season.
When unit is not in use, always park it in a heated 
building.
While in operation, avoid long shutdowns as the unit 
provides heat while running. Shut it down just prior to 
leaving for the next job.
If a heated building is not available, we recommend 
that you winterize the unit with anti-freeze.

WARNING: When disposing of anti-freeze, 
observe local laws and regulations. Do not 
drain onto ground or into storm drainage 
systems.

NOTE: Inspect and clean exchanger core and box ev-
ery 500 hours.
NOTE:  The heat exchanger will produce water con-
densation discharge at times during normal operation. 
DO NOT confuse this with a leak.

Содержание ECOS 7000

Страница 1: ...OPERATOR S MANUAL ECOS 7000 1 103 825 0 LISTED For technical assistance or the dealer nearest you consult our web page at www landa com 9 801 316 0 98013160 1 US Patent US 2011 0232696 A1...

Страница 2: ...fety 3 Reporting Safety Defects 3 Checklist Before Your First Trip 3 What to Check How to Check 3 5 Brakes 5 6 Towing Instruction 6 Trailer Storage 6 7 SAFETY INFORMATION Warnings 8 9 ASSEMBLY AND OPE...

Страница 3: ...Administration NHTSA in addition to notifying customer If NHTSA receives similar complaints it may open an investigation and if it finds that a safety defect exists in a group of vehicles it may order...

Страница 4: ...coupler diameter Never attempt to tow your trailer with improper size ball Always keep ball greased to avoid excessive wear Replace worn hitch ball or locking dogs promptly 1 2 3 4 5 Tires Before mou...

Страница 5: ...tow vehicle pull the safety pin on the breakaway switch Check to see if system is operational Push safety pin back in to its original position Breakaway Switch Mounted on an A Frame Attach breakaway s...

Страница 6: ...rotating The following two rules may limit your vehicle s towing capacity and the tank fill level when towed Determine towing capacity as described below and follow guide lines in using the lowest va...

Страница 7: ...l safety and the protection of others Maintenance Schedule Tire Air Pressure Inflate to proper pressure 50 psi Wheel Lugs Bolts and Nuts Tighten to proper torque specifications Every 3000 mi or 3 mo W...

Страница 8: ...SURE SPRAY CAN PIERCE SKIN AND TISSUES CAUTION WARNING KEEP WATER SPRAY AWAY FROM ELECTRICAL WIRING WARNING OPERATE ONLY WHEN BELT GUARD IS IN PLACE WARNING READ OPERATOR S MANUAL THOROUGH LY PRIOR TO...

Страница 9: ...NG RISK OF ASPHYXIATION USE THIS PRODUCT ONLY IN A WELL VENTILATED AREA WARNING RISK OF INJURY FROM FALLS WHEN USING LADDER WARNING Risk of asphyxiation Use this product only in a well ventilated area...

Страница 10: ...ity of Oil Engine oils with API Service Classifications SF SG SH or SJ are recommended NOTE Using multi grade oils 5W 20 10W 30 and 10W 40 will increase oil consumption Check oil level more frequently...

Страница 11: ...ater can be sprayed at machine Locate the equipment on a solid level area with slopes for drainage When operating upon unlevel ground posi tion trailer with hitch end at the downhill side WARNING Do n...

Страница 12: ...lly Cle an Op era tin g Sy ste m COMPONENT IDENTIFICATION Coil Vacuum Motor Diesel Gasoline Tank Compartment Hose Reels Control Panel Compartment Filters Vacuum Hose Storage Box Outer Water Tanks Vac...

Страница 13: ...Pressure Hose Male Coupler 98013160 29 To prevent injury or damage when transporting trailer attach the loose ends of both hoses to the fittings located on the base of the upper reel Wind reels to re...

Страница 14: ...ch on The green light will be illuminated when the burner switch is in the on position 98013160 11 98013160 12 3 2 1 VACUUM RECLAIM BURNER PUM P ON OFF POW ER Se nD EC TA CH HO UR 1 1 0 98013160 13 ST...

Страница 15: ...s in operation Allow machine to cool down completely before attempting to service this area Always wear hearing protection and proper per sonal protection equipment when operating unit HEAT EXCHANGER...

Страница 16: ...e control cabinet to the ON posi tion The vacuum system will draw water into the 40 gallon holding tank and will automatically stop when the tank is full STEP 3 Located in the vacuum tank is the large...

Страница 17: ...ke sure o ring is in place put it back in position and turn clockwise STEP 2 Remove the used filter from the filter housing be sure not to lose the black o ring VACUUM OPERATING INSTRUCTIONS STEP 4 To...

Страница 18: ...ve to the outer tank position OPTION 2 To draw water from the inner tanks set the outer tank valve to the OFF position and the inner tank valve to the ON position Set the Bypass valve to the inner tan...

Страница 19: ...k disconnect the 3 4 JIC on bottom of tank Re connect hose when tank is empty 98013160 27 Hinge Pin Cotter Pin To swing the tongue away for storage pull the cotter pin and remove the hinge pin Rotate...

Страница 20: ...parts Worn or damaged hose Repair replace hose Broken valve spring Replace spring Pulse valve on Turn off pulse valve Improper adjustment of unloader Adjust as necessary ROUGH OPERATION WITH LOSS OF...

Страница 21: ...uct as necessary to achieve proper concentration DETERGENT IN RINSE CYCLE Dual lance wand or adjustable nozzle holder in open position or chemical me tering valve open Close dual lance wand adjustable...

Страница 22: ...place parts as necessary Clogged nozzle Clean or replace FLUID LEAKING FROM BODY O ring worn or cut Replace part as necessary UNLOADER WILL NOT COME TO PRESSURE Foreign particle in valve Replace or cl...

Страница 23: ...hine from severe damage caused by water freezing inside the components it is important to winterize it whenever it is subjected to freezing temperatures The best way to protect the system is to keep i...

Страница 24: ...t Hot Water Thermostat For safety each machine is equipped with a tempera ture sensitive high limit control switch In the event that the water should exceed its operating temperature the high limit co...

Страница 25: ...osion NEVER use crankcase or waste oil in your burner Fuel unit malfunction could result from contamination Fuel Control System This machine utilizes a fuel solenoid valve located on the fuel pump to...

Страница 26: ...nd position Next slowly open the air shutter until white smoke just starts to appear Turn air shutter halfway back to the black smoke position previously noted Tighten locking screws If the desired po...

Страница 27: ...etergent 10 40W Inspect Oil level daily Change After first 50 hours then every 500 hours or annually Clean Burner Filter Monthly More often if fuel quality is poor Remove Burner Soot Annually Burner A...

Страница 28: ...d general integrity of links Every trip Coupler Check for proper fastening hitch pin in position and secure Every trip Brakes Check for proper adjustment operation Every trip Breakaway Switch Test swi...

Страница 29: ...TEMS ARE NOT COVERED BY THIS WARRANTY Suspension axles hubs drums brakes bearings and seals These are subject to the warranties if any of their manufac turers WE SHALL NOT BE LIABLE FOR SPECIAL INDIRE...

Страница 30: ...Form 9 801 316 0 Landa ECOS 7000 Operator Manual Rev 12 12 Printed in U S A or Mexico...

Отзывы: