Chapter 2: Installation
16
EN
The power LED blinks alternately in red/green until a configuration
password has been set. Without a configuration password, the con-
figuration data in the LANCOM is unprotected. Normally you would
set a configuration password during the basic configuration (instruc-
tions in the following chapter). Information about setting a configu-
ration password at a later time is available in the section 'The Security
Wizard'.
WLAN Link or
WLAN Link 1/2
Provides information about the WLAN connections via the internal WLAN
modules.
Red/green
Blinking alter-
nately
Device insecure: Configuration password not set
Orange/green
In the housing
cover; blinking
alternately with
the online LED
At least one WLAN module is in managed mode and
has not found a WLAN Controller yet. The correspond-
ing WLAN module(s) is/are switched off until a WLAN
Controller is found to supply a configuration, or until
being switched manually into another operating mode.
Orange /red
In the housing
cover; blinking
alternately with
the online LED
At least one WLAN module is in managed mode and
has found a WLAN Controller. However, the WLAN
Controller cannot assign a configuration because the
firmware and/or the device's loader version is not com-
patible with the WLAN Controller.
The power LED is blinking and no connection can be
made?
If the power LED blinks red and no WAN connections can be
established, there is no cause for concern. This merely means
that a pre-set charge or time limit has been reached.
There are three ways to remove the lock:
Reset the toll protection.
Increase the limit.
Deactivate the lock completely (set limit to '0').
LANmonitor shows you when a charge or time limit has been reached. To reset the toll protec-
tion, activate the context menu (right-mouse click)
Reset charge and time limits
. The charge
settings are defined in LANconfig under
Management
Costs
(these settings are only avail-
able if the 'Complete configuration display' is activated under
Tools
Options
).
With WEBconfig, charge protection and all parameters are to be found under
LCOS menu tree
Setup
Charges
Reset budgets
.
Power
P
ower
Signal that a
charge or time
limit has been
reached