Scope of features: as of LCOS version 8.5x

SSH & Telnet client

SSH- client function compatible to Open SSH under Linux and Unix operating systems for accessing third- party components from 
a LANCOM router. Also usable when working with SSH to login to the LANCOM device. Support for certificate-  and password-
based authentication. Generates its own key with sshkeygen. SSH client functions are restricted to administrators with 
appropriate rights. Telnet client function to login/administer third party devices or other LANCOM devices from command line 
interface

HTTPS Server

Option to choose if an uploaded certificate or the default certificate is used by the HTTPS server

Security

Access rights (read/write) over WAN or (W)LAN can be set up separately (Telnet/SSL, SSH, SNMP, HTTPS/HTTP), access control list

Scripting

Scripting function for batch- programming of all command- line parameters and for transferring (partial) configurations, 
irrespective of software versions and device types, incl. test mode for parameter changes. Utilization of timed control (CRON) or 
connection establishment and termination to run scripts for automation. Scripts can send e- mails with various command line 
outputs as attachments

Load commands

LoadFirmware, LoadConfig and LoadScript can be executed conditionally in case certain requirements are met. For example, the 
command LoadFirmware could be executed on a daily basis and check each time if the current firmware is up to date or if a new 
version is available. In addition, LoadFile allows the upload of files including certificates and secured PKCS- 12 containers

SNMP 

SNMP management via SNMPv2, new unified private MIB for all most current and future LANCOM devices with LCOS. Download 
link in WEBconfig

SNMP 

SNMP management via SNMPv2, private MIB exportable by WEBconfig, MIB II

Timed control

Scheduled control of parameters and actions with CRON service 

Diagnosis

Extensive LOG and TRACE options, PING and TRACEROUTE for checking connections, LANmonitor status display, internal logging 
buffer for SYSLOG and firewall events

LANCOM WLAN Controller

Supported by all LANCOM WLAN Controller (separate optional hardware equipment for installation, optimization, operating and 
monitoring of WLAN networks, except for P2P connections)

SYSINFO

SYSINFO provides additional information. Hash value for the current configuration, time stamp of the last configuration change, 
a persistent counter of the number of configuration changes and the output of the value CONFIG_STATUS

Statistics

Statistics

Extensive Ethernet, IP and DNS statistics; SYSLOG error counter

Accounting

Connection time, online time, transfer volumes per station. Snapshot function for regular read- out of values at the end of a 
billing period. Timed (CRON) command to reset all counters at once

Export

Accounting information exportable via LANmonitor and SYSLOG

Hardware

Power supply

12 V DC, external power adapter (230 V)

Power supply

Via Power over Ethernet, compliant with IEEE 802.3af

Environment

Temperature range 0–45C; humidity 0–95%; non- condensing

Housing

Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; 210 x 45 x 140 mm (W x H x D)

Power consumption (max)

approx. 10.7 Watt with 12 V/ 1 A power supply adapter (total power consumption of access point and power supply adapter), 
approx. 14.4 Watt via PoE

Declarations of conformity

CE

EN 301 489- 1, EN 301 489- 17, EN 60950

2.4 GHz WLAN

ETS 300 328

5 GHz WLAN

EN 301 893 version 1.5.1, EN 302 502 (BFWA)

Notifications

Certifications notified in Germany, Belgium, Netherlands, Luxembourg, Austria, Switzerland, UK, Italy, Spain, France, Portugal

Package content

Manual

Installation Guide (DE/EN/FR/ES/IT/PT/NL)

CD/DVD

Data medium with firmware, management software (LANconfig, LANmonitor, WLANmonitor) and documentation

Cable

Serial configuration cable, 1.5m

Cable

1 Ethernet cable, 3 m

Antenna

Four 3 dBi dipole dualband antennas

Power supply unit

12 V DC, external power adapter (230 V)

Support

Warranty

3 years 

Support via Hotline and Internet KnowledgeBase

Software updates

Regular free updates (LCOS operating system and LANCOM Management System) via Internet

Management

Содержание L-322agn

Страница 1: ...s Point with MIMO technology Two integrated 11n radio modules for simultaneous 2 4 and 5 GHz wireless network operations Power supply via IEEE 802 3af PoE Separation of user groups by Multi SSID and V...

Страница 2: ...e individual requirements For example Multi SSID allows the definition of up to 8 user groups each with its own level of security More Management LANCOM s WLAN management tools offer real benefits to...

Страница 3: ...Mbps MCS8 40 MHz 72 dBm 300 Mbps MCS15 40 MHz Radio channels 2 4 GHz Up to 13 channels max 3 non overlapping 2 4 GHz band Radio channels 5 GHz Up to 26 non overlapping channels available channels and...

Страница 4: ...anaged by LANCOM WLAN Controller WLAN bridge Point to multipoint connection of up to 7 Ethernet LANs mixed operation optional broken link detection blind mode supports VLAN When configuring Pt to Pt l...

Страница 5: ...t management and configuration of IP networks in the device i e individual settings for DHCP DNS Firewalling QoS VLAN Routing etc Automatic learning of routing tags for ARF contexts from the routing t...

Страница 6: ...yLANCOM download server myLANCOM account mandatory Updates can be applied directly after the download or at a later time Management WEBconfig Integrated web server for the configuration of LANCOM devi...

Страница 7: ...checking connections LANmonitor status display internal logging buffer for SYSLOG and firewall events LANCOM WLAN Controller Supported by all LANCOM WLAN Controller separate optional hardware equipme...

Страница 8: ...a AirLancer Extender O 360ag dualband omnidirectional outdoor antenna item no 61223 External antenna AirLancer Extender I 60ag dualband indoor sector antenna item no 61214 External antenna AirLancer E...

Отзывы: