The online LED displays the general status of all WAN interfaces:
ADSL status
( LANCOM
821+ and
LANCOM
1721+ VPN
only)
Information on connection status at the ADSL connector:
Flashing Power LED but no connection?
There's no need to worry if the Power LED blinks red and you can no
longer connect to the WAN. This simply indicates that a preset time or
connect-charge limit has been reached. There are three methods
available for unlocking:
Reset connect charge protection.
Increase the limit that has been reached.
Completely deactivate the lock that has been triggered (set limit
to '0').
If a time or connect charge limit has been reached, you will be notified in LANmonitor. To
reset the connect charge protection, select
Reset Charge and Time Limits
in the context
menu (right mouse click). You can configure the connect charge settings in LANconfig under
Management
Costs
(you will only be able to access this configuration if 'Complete con-
figuration display' is selected under
View
Options…
).
You will find the connect charge protection reset in WEBconfig and all parameters under
Expert Configuration
Setup
Charges- module
.
Signal for reached time
or connect-charge
limit
Power
P
ower
Off
No active connection
Green
Flashing
Opening the first connection
Green
Inverse flashing
Opening an additional connection
Green
On (perma-
nently)
At least one connection is established
Red
On (perma-
nently)
Error establishing the last connection
Off
Interface deactivated
Green
Blinking/flashing
Handshake/training
Green
Permanently
Synchronization successful
Red
Flickering
Error (CRC error, framing error, etc.)
Red
On (permanently)
No synchronization, searching for remote station
Red/
orange
Blinking
Hardware error