lancer 28-0940 Скачать руководство пользователя страница 6

6

 

1.4  LEVELING THE DISPENSER

 

 

In order to facilitate proper dispenser drainage, ensure 

that the dispenser is level, front to back and side to side. 

Place a level on the top of the rear edge of the dispenser. 

The bubble must settle between the level lines. Repeat 

this procedure for the remaining three sides. Level unit if 

necessary. For optimum performance place the unit at a 

0° tilt.

!

CAUTION

 THE ICE USED IN THIS UNIT MAY NOT BE POTABLE AND SHOULD NOT BE INGESTED. DO NOT EAT, 

CHEW, SUCK, SWALLOW, OR PUT INTO DRINKS. THE ICE USED IN THIS UNIT IS INTENDED SOLELY FOR THE 

REFRIGERATION PURPOSES OF THE PRODUCT. 

PRECAUCIÓN 

 EL HIELO SE USA EN ESTA UNIDAD NO ES POTABLE Y NO SE DEBEN INGERIR. NO COMER, 

MASTICAR, SUCCIONAR, TRAGAR, O PUESTOS EN BEBIDAS. EL HIELO SE USA EN ESTA UNIDAD HA SIDO 

DISEÑADA EXCLUSIVAMENTE PARA LA FINES DE REFRIGERACIÓN DEL PRODUCTO.

ATTENTION

 LA GLACE UTILISÉS DANS CET APPAREIL N’EST PAS POTABLE ET NE DOIT ÊTRE INGÉRÉ. NE PAS 

MANGER, DE MÂCHER, SUCEZ, HIRONDELLE, OU MIS EN BOISSONS. LA GLACE UTILISÉE DANS CET APPAREIL 

EST DESTINÉ UNIQUEMENT À L’REFRIGERATION FINS DU PRODUIT.

 

1.3  SELECTING COUNTER LOCATION

  

Connecting lines can be run through the front of the unit and can extend down through a 

 

 

counter cutout. Select a level, well ventilated, accessible location away from direct sunlight (avoid) 

or overhead lighting. The selected location should be able to support the weight of the unit with the 

ice after counter cut out is made (if applicable).

 

1.5  INSTALLATION OF THE UNIT

 

 

A.  Remove Top Cover.

 

 

B.  Connect Product supply line to 3/8 inch barb fitting located at the front of the unit. 

 

 

C.  Connect other end of Product supply line to keg coupler using 3/8 inch barb fitting

 

 

D.  Attach keg coupler on to the keg by turing clockwise until it stops. Check for leaks.

 

 

E.  Install the ice bin drain hose; connect the 90° elbow or straight fitting underneath the unit’s    

 

base. The ice bin drain is located towards the front of the bin and slightly to the left. Connect  

 

the hose. Extend the hose to an open type drain.

 

 

F.  Drain line must be insulated with a closed cell insulation. Insulation must cover the entire length  

 

of the drain hose, including fittings. The drain should be installed in such a manner that water  

 

does not collect in sags or other low points, as condensation will form.

 

 

G.  Fill unit with ice and Install Top Cover and Drip Tray. 

2.   RECOMMENDED SERVICE AND MAINTENANCE
 

2.1  REPLACE BEER KEG

   NOTE: 

Excessive foaming is caused by a nearly empty beer keg. Replace it with a new keg as 

soon as possible. When a beer keg becomes completely empty, CO2 gas will blow out of the beer 

tap and splash beer.

 

 

A.  Close the beer circuit by turning the keg coupler handle counter-clockwise until it stops.

 

 

B.  Turn the keg coupler further counter-clockwise and remove it from the keg.

 

 

C.  Remove empty keg.

 

 

D.  Attach the keg coupler on the new keg by turning clockwise. 

  

NOTE:

 Wash the keg joint with water if necessary. 

 

 

E.  Open the beer circuit by turning the keg coupler clockwise until it stops. 

  

NOTE:

 Check that the beer tap lever is closed. Opening the keg coupler with the beer tap lever 

open will cause beer to splash out. 

 

  

F.  Set a mug (container) to recieve beer and push the beer tap lever hard to the back (Foam 

 

 

 

Position). Keep pushing it to dispense foam. When the mug is half filled with foam, move lever  

 

back to original (Stop) position. 

 

 

G.  Wait for more than a minute to settle beer in circuit.

 

 

H.  Set mug (contianer) and pull the beer tap lever toward you to dispense beer. Keep dispensing  

 

beer until foam turns to liquid. 

Содержание 28-0940

Страница 1: ...al PN 28 0940 Lancer is the registered trademark of Lancer 2014 by Lancer all rights reserved CP 09 Please refer to the Lancer Corp website lancercorp com for information relating to Lancer Installation Operation Manuals Installation Guides Instruction Sheets and Technical Bulletins or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical ...

Страница 2: ... must be carried out by qualified personnel with up to date safety and hygiene knowledge and practical experience in accordance with current regulations TABLE OF CONTENTS SPECIFICATIONS 3 PRE INTALLATION CHECKLIST 4 WARNINGS CAUTIONS 5 1 INSTALLATION 5 1 1 UNPACKING THE DISPENSER 5 1 2 DRAIN SPIDER 5 1 3 SELECTING COUNTER LOCATION 6 1 4 LEVELING THE DISPENSER 6 1 5 INSTALLATION OF THE UNIT 6 2 REC...

Страница 3: ...inches 293 87 mm Depth 19 77 inches 502 17 mm Height 15 54 inches 394 71 mm Depth w Dip Tray 24 87 inches 631 70 mm WEIGHT Shipping 55 lbs 24 95 kg Empty 50 lbs 22 68 kg ICE Capacity 19 4 lbs 8 8 kg PRODUCT SUPPLY Minimum pressure 42 PSI 0 289 MPA Maximum pressure 46 PSI 0 317 MPA FITTINGS Product inlet 5 16 barb ...

Страница 4: ...aim with carrier Responsibility for damage to the dispenser lies with the carrier Your Service Agent __________________________________ Service Agent Telephone Number ______________________ Serial Number _______________________________________ Installation Date _____________________________________ TOOLS REQUIRED Oetiker Pliers Tubing Cutters Faucet Wrench CONSIDER THE FOLLOWING PRIOR TO INSTALL D...

Страница 5: ... aplicables Advertencias de las instrucciones sobre el producto utilizado se deben seguir Cet appareil n est pas un jouet Les enfants doivent être surveillés afin de ne pas jouer avec l appareil Il ne devrait pas être utilisé par des enfants ou des personnes infirmes sans surveillance Cet appareil n est pas destiné à un usage par des personnes y compris les enfants ayant des capacités physiques se...

Страница 6: ...upler using 3 8 inch barb fitting D Attach keg coupler on to the keg by turing clockwise until it stops Check for leaks E Install the ice bin drain hose connect the 90 elbow or straight fitting underneath the unit s base The ice bin drain is located towards the front of the bin and slightly to the left Connect the hose Extend the hose to an open type drain F Drain line must be insulated with a clo...

Страница 7: ...GRÉS F 60 DEGRÉS C CECI PEUT ENDOMMAGER LE DISTRIBUTEUR 3 CLEANING AND SANITIZING INSTRUCTIONS 3 1 GENERAL INFORMATION A The cleaning and sanitizing procedures provided pertain to the Lancer equipment identified by this manual If other equipment is being cleaned follow the guidelines established by the manufacturer for that equipment B Lancer equipment new or reconditioned is shipped from the fact...

Страница 8: ...al regulations regarding disposal of the insulation 3 4 DAILY CLEANING A Using the cleaning solution clean Top Cover and all exterior stainless steel surfaces B Clean exterior of dispensing valves C Remove Drip Tray by lifting to release its mounting holes from the mounting screws D Dump water and beer and wash the Drip Tray and Splash Plate with cleaning solution E Lift the Drip Tray to hook the ...

Страница 9: ... 1 EXPLODED VIEW 1 3 2 4 5 Item Part No Description 1 30 11859 Cup Rest Breeze Beer 2 01 2976 Elbow Connector JG 3 8 X5 16 3 05 3266 Drip Tray Breeze Beer 4 04 1682 2 Screw M4 0 7X4 5 4 5 Shoulder FHD PH SS 5 30 11833 Lid Metal Breeze Beer ...

Страница 10: ...NOTES 10 ...

Страница 11: ...INTENTIONALLY LEFT BLANK 11 ...

Страница 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com ...

Отзывы: