![lancer 28-0940 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/lancer/28-0940/28-0940_installation-and-operation-manual_3475500006.webp)
6
1.4 LEVELING THE DISPENSER
In order to facilitate proper dispenser drainage, ensure
that the dispenser is level, front to back and side to side.
Place a level on the top of the rear edge of the dispenser.
The bubble must settle between the level lines. Repeat
this procedure for the remaining three sides. Level unit if
necessary. For optimum performance place the unit at a
0° tilt.
!
CAUTION
THE ICE USED IN THIS UNIT MAY NOT BE POTABLE AND SHOULD NOT BE INGESTED. DO NOT EAT,
CHEW, SUCK, SWALLOW, OR PUT INTO DRINKS. THE ICE USED IN THIS UNIT IS INTENDED SOLELY FOR THE
REFRIGERATION PURPOSES OF THE PRODUCT.
PRECAUCIÓN
EL HIELO SE USA EN ESTA UNIDAD NO ES POTABLE Y NO SE DEBEN INGERIR. NO COMER,
MASTICAR, SUCCIONAR, TRAGAR, O PUESTOS EN BEBIDAS. EL HIELO SE USA EN ESTA UNIDAD HA SIDO
DISEÑADA EXCLUSIVAMENTE PARA LA FINES DE REFRIGERACIÓN DEL PRODUCTO.
ATTENTION
LA GLACE UTILISÉS DANS CET APPAREIL N’EST PAS POTABLE ET NE DOIT ÊTRE INGÉRÉ. NE PAS
MANGER, DE MÂCHER, SUCEZ, HIRONDELLE, OU MIS EN BOISSONS. LA GLACE UTILISÉE DANS CET APPAREIL
EST DESTINÉ UNIQUEMENT À L’REFRIGERATION FINS DU PRODUIT.
1.3 SELECTING COUNTER LOCATION
Connecting lines can be run through the front of the unit and can extend down through a
counter cutout. Select a level, well ventilated, accessible location away from direct sunlight (avoid)
or overhead lighting. The selected location should be able to support the weight of the unit with the
ice after counter cut out is made (if applicable).
1.5 INSTALLATION OF THE UNIT
A. Remove Top Cover.
B. Connect Product supply line to 3/8 inch barb fitting located at the front of the unit.
C. Connect other end of Product supply line to keg coupler using 3/8 inch barb fitting
D. Attach keg coupler on to the keg by turing clockwise until it stops. Check for leaks.
E. Install the ice bin drain hose; connect the 90° elbow or straight fitting underneath the unit’s
base. The ice bin drain is located towards the front of the bin and slightly to the left. Connect
the hose. Extend the hose to an open type drain.
F. Drain line must be insulated with a closed cell insulation. Insulation must cover the entire length
of the drain hose, including fittings. The drain should be installed in such a manner that water
does not collect in sags or other low points, as condensation will form.
G. Fill unit with ice and Install Top Cover and Drip Tray.
2. RECOMMENDED SERVICE AND MAINTENANCE
2.1 REPLACE BEER KEG
NOTE:
Excessive foaming is caused by a nearly empty beer keg. Replace it with a new keg as
soon as possible. When a beer keg becomes completely empty, CO2 gas will blow out of the beer
tap and splash beer.
A. Close the beer circuit by turning the keg coupler handle counter-clockwise until it stops.
B. Turn the keg coupler further counter-clockwise and remove it from the keg.
C. Remove empty keg.
D. Attach the keg coupler on the new keg by turning clockwise.
NOTE:
Wash the keg joint with water if necessary.
E. Open the beer circuit by turning the keg coupler clockwise until it stops.
NOTE:
Check that the beer tap lever is closed. Opening the keg coupler with the beer tap lever
open will cause beer to splash out.
F. Set a mug (container) to recieve beer and push the beer tap lever hard to the back (Foam
Position). Keep pushing it to dispense foam. When the mug is half filled with foam, move lever
back to original (Stop) position.
G. Wait for more than a minute to settle beer in circuit.
H. Set mug (contianer) and pull the beer tap lever toward you to dispense beer. Keep dispensing
beer until foam turns to liquid.