Display is not lit
1.
Ensure the power to the rough-in box is turned on (check circuit breaker).
2.
Ensure brewer is fully pressed into the rough-in box.
3.
Ensure the outlet inside the rough-in box is properly wired. Remove the brewer
and check outlet with volt meter. If power is on and no voltage is detected at the
outlet, wiring is incorrect. Turn off power. Remove power panel cover (two screws)
and check wire source connection.
4.
Check wire connection at source.
Water does not flow from spray head
1.
If the BREW EXPRESS™ has not been used for 20 minutes or longer, it will PREHEAT
the water for 30 seconds. You may be waiting for the preheat cycle to end.
2.
Ensure water has been turned on to the BREW EXPRESS™ (check valve at source).
3.
Ensure the carafe or mug is centered under under the brew basket. BREW EXPRESS™
will not start if the detection sensor dose not see a carafe or mug. Operation light should blink.
The detection sensor may not see a flat black surface. If mug or carafe is flat black,
then try a different color.
4.
Check the water filter at the supply. If filter is clogged replace filter.
5.
Ensure the water line is properly connected inside the rough-in box. Remove the four
screws on the side and pull out brewer. Check for pinched or kinks in the water supply
line. The connector from the brewer must be pressed securely into connector from from
water source.
6.
Ensure the water pressure is adequate. The BREW EXPRESS™ will not operate if water
pressure is under 30 PSI. LED display will flash EEEE if water pressure is too low.
7.
If problem persists as EEEE indicates, and no water filter is installed (at source) coffee system
maybe clogged by water debris. Contact dealer or Lance Larkin™ for service. 1(866)268-5953
7