background image

PAGE 9

DRIVE CAP ASSEMBLY, MAIN PISTON AND REGENERANT PISTON:

The drive gears turn the main gear of the drive cap assembly, which moves the piston. The screw-driven, horizontally 

moving piston stops at specific positions to direct the flow of water to backwash, regenerate, rinse or refill. The PC board 

determines the position of the piston by counting pulses produced when the piston is moved. An optical sensor looking 

at one of the reduction drive gears generates these pulses. Each cycle position is defined by a number of pulses. The 

counter is zeroed each time the valve goes to the service position. The PC board finds the service position by noting the 

increase in current delivered to the motor when the mechanical stop at the service position is reached. This method of 

controlling piston position allows for greater flexibility and requires no switches or cams (U.S. Patent 6444127).

A regenerant piston must be attached to the main piston.

SPACER STACK ASSEMBLY:

The spacer stack assembly provides the necessary flow passage for water during the different cycles. The all-plastic 

spacer stack assembly (U.S. Patent 6402944) is a one-piece design which allows the stack to be removed using your 

fingers. 
The exterior of the stack is sealed against the body bore with self lubricating EPDM o-rings, while the interior surface is 

sealed against the piston using slippery self cleaning directional (one-way) silicone lip seals. The lip seals are clear in 

color and have a special slippery coating so that the piston does not need to be lubricated.

Replace broken or damaged drive gears. Do not lubricate any of the gears. Avoid getting any foreign matter on the 

reflective coating because dirt or oils may interfere with pulse counting. 
The drive gear cover only fits on one way, with the large clip orientated towards the bottom. If all three clips are outside of 

the gear shroud on the drive bracket the drive gear cover slips easily into place. 
The drive bracket does not need to be removed from the drive plate if the motor needs to be removed. To remove the 

motor, disconnect the power and motor plugs from the jacks on the PC board. Move the spring clip loop to the right and 

hold. Rotate the motor at least a ¼ turn in either direction so the wires are vertical (up & down) before gently pulling on the 

wire connectors to remove the motor. Pulling directly on the wires without rotating the motor may break the wires off the 

motor. 

Содержание XFactor 7-PEL-75B

Страница 1: ...talled in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes please file this booklet with your im...

Страница 2: ...ne prior to connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control f...

Страница 3: ...er supply inlet after pressure tank and near a source for waste water utility sink floor drain or sewer line A 115 120V 60 Hz uninterrupted outlet is required Keep softener far enough away from walls...

Страница 4: ...of the overflow Do not connect the tubing to the drain line on the control valve Do not run tubing above overflow height at any point PROGRAMMING THE CONTROL VALVE Note A quick reference card is stor...

Страница 5: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Страница 6: ...g steadily to drain without the presence of air momentarily press REGEN again Display will read RINSE Open the outlet valve of the softener or if using optional bypass place to NORMAL OPERATION MODE f...

Страница 7: ...is required The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles The handles identify the flow direction of the water The plug valves ena...

Страница 8: ...reinstall the PC board position the lower edge of the PC board so that the holes in the PC board line up with the plastic pins Push the top of the PC board towards the valve until it snaps under the...

Страница 9: ...atent 6402944 is a one piece design which allows the stack to be removed using your fingers The exterior of the stack is sealed against the body bore with self lubricating EPDM o rings while the inter...

Страница 10: ...l flow control assembly is installed in an easy to access refill elbow located on top of the control valve The refill flow control assembly is attached to the control valve with a locking clip The loc...

Страница 11: ...ector Assy E White 5 1 V3010 1F Injector Assy F Blue 5 1 V3010 1G Injector Assy G Yellow Not Shown V3170 O Ring 011 Not Shown V3171 O Ring 013 Injector plug and injector each contain one 011 and one 0...

Страница 12: ...lbow Locking Clip 1 2 PKP10TS8 BULK Polytube insert 5 8 Option 3 V3192 WS1 Nut Drain Elbow Option 4 V3158 01 WS1 Drain Elbow Male 1 5 V3163 O ring 019 1 6 V3159 01 WS1 DLFC Retainer ASY 1 7 V3162 007...

Страница 13: ...150 Split Ring 3 2 V3105 O Ring 215 4 2 V3149 1 PVC Male NPT Elbow Item No Qty Part No Description 1 1 H4600 3 8 Safety Brine Valve 2 2 10151 Pin 3 1 H4640 32 Float Assembly 4 1 H4500 30 50 Air Check...

Страница 14: ...e jack black wire and plug back in to reset control valve e Motor not inserted fully to engage pinion motor wires broken or disconnected motor failure e Check motor and wiring Replace motor if necessa...

Отзывы: