PAGE 4

ADDITIONAL PROGRAMMING INFORMATION AVAILABLE FROM 

LANCASTER WATER TREATMENT UPON REQUEST. 

SET HARDNESS, DAYS OVERRIDE & REGENERATION TIME

STEP 1: Press 

NEXT

 and ▲ simultaneously for 3 seconds.

STEP 2:

Hardness:

  Set  the  amount  of  hardness  in  grains  of  hardness 

as calcium carbonate per gallon using the ▲ or ▼ buttons. The 

default is 20. The available range is 1 to 150 in 1 grain increments.

STEP 3: Press 

NEXT

. Regen day: This sets the maximum number of days 

between regenerations. This days override feature can be shut off 

by pressing the ▼ button until “OFF” appears. Set the maximum 

number  of days between  by pressing  ▲ or ▼. Range  is 1– 28 

days. If the OFF position is selected, the softener will regenerate 

based solely on the gallons capacity.

STEP 4:  Press 

NEXT

. Regeneration time (hour): Set the hour of  the day for 

regeneration to occur by using ▲ or ▼ buttons. AM/ PM toggles 

after 12. The default time is 2:00 am.

STEP 5:  Press 

NEXT

. Regeneration time (minutes): Set the minutes of the 

day for regeneration by using ▲ or ▼ buttons. Press 

NEXT

 to exit 

Displays/Settings. Current time of day will be displayed.

PLACING  UNIT  INTO  SERVICE:

  Make  sure  inlet  and  outlet  valves  are  to  their  closed  positions.  If  using  optional 

bypass, place in bypass position. Turn on main water supply. Open a cold water faucet. This will clear the lines of any debris 

(solder, pipe dope, etc.) that may be in the line. Let water run at tap for a couple of minutes, or until clear. Turn off faucet. 

Manually add 1½ gallons of water to the brine tank.
• 

Press and hold the 

REGEN

 button for approximately 5 seconds until the motor starts. 

• 

Wait until display reads 

BACKWASH

 and numbers start counting down.

• 

Momentarily press 

REGEN

 again. Wait until display reads 

BRINE

 and numbers start counting down.

• 

Momentarily press 

REGEN

 again. Valve is now in the second 

BACKWASH

 position.

If using optional bypass 

SLOWLY

 turn bypass valve to 

DIAGNOSTIC

 position

 (figure 2)

 or slowly open inlet valve to allow 

water to slowly enter the softener.

When water is flowing steadily to drain without the presence of air, momentarily press 

REGEN

 again. Display will read 

RINSE

.

Open the outlet valve of the softener, or if using optional bypass place to 

NORMAL OPERATION MODE

 

(figure 3)

.

Allow control to finish the

 RINSE

 cycle. It will then advance to the 

FILL

 position. The brine tank will now automatically fill with 

the proper volume of water for the first regeneration.

Allow the control to automatically advance to the 

SOFTENING

 position.

Load the brine tank with salt. Solar Salt is recommended.

SANITIZING

: Use 2 oz. of 5¼% household chlorine bleach for each cubic foot of resin. Pour bleach directly into the brine 

well of the softener. Press and hold the REGEN button for 5 – 6 seconds until the motor starts running. Allow system to 

 

complete the regeneration automatically. Check for other local and state codes which may also specify sanitation methods.

FIGURE 3

FIGURE 2

 

 

PLACING  UNIT  INTO  SERVICE:

 

Make  sure  inlet  and  outlet  valves  are  to  their  closed  positions.  If  using  optional  

bypass, place in bypass position. Turn on main water supply. Open a cold water faucet. This will clear the lines of any debris 

(solder, pipe dope, etc.) that may be in the line. Let water run at tap for a couple of minutes, or until clear. Turn off faucet. 

Manually add 1½ gallons of water to the brine tank. 

 



Press and hold the 

REGEN 

button for approximately 5 seconds until the motor starts.  



Wait until display reads 

BACKWASH

 and numbers start counting down. 



Momentarily press 

REGEN

 again. Wait until display reads 

BRINE

 and numbers start counting down. 



Momentarily press 

REGEN

 again. Valve is now in the second 

BACKWASH

 position. 

 

If using optional bypass 

SLOWLY

 turn bypass valve to 

DIAGNOSTIC

 position 

(figure  2)

 or slowly open inlet valve to allow 

water to slowly enter the softener. 

 

When water is flowing steadily to drain without the presence of air, momentarily press 

REGEN

 again. Display will read 

RINSE

 

Open the outlet valve of the softener, or if using optional bypass place to 

NORMAL OPERATION MODE (figure 3). 

 

Allow control to finish the 

RINSE

 cycle. It will then advance to the 

FILL

 position. The brine tank will now automatically fill with 

the proper volume of water for the first regeneration. 

 

Allow the control to automatically advance to the 

SOFTENING

 position. 

 

Load the brine tank with salt. Solar Salt is recommended. 

 

SANITIZING:

 Use 2 oz. of 5¼% household chlorine bleach for each cubic foot of resin. Pour bleach directly into the brine 

well  of  the  softener.  Press  and  hold  the 

REGEN

  button  for  5  –  6  seconds  until  the  motor  starts  running.  Allow  system  to  

complete the regeneration automatically. Check for other local and state codes which may also specify sanitation methods. 

STEP 1: Press 

NEXT

 and ▲ simultaneously for 3 seconds. 

 

STEP  2: 

Hardness

:  Set  the  amount  of  hardness  in  grains  of  hardness  as 

 

calcium carbonate per gallon using the ▲ or ▼ buttons. The default 

 

is 20. The available range is 1 to 150 in 1 grain increments. 

 

STEP 3: Press 

NEXT

. Regen day: This sets the maximum number of days 

 

between regenerations. This days override feature can be shut off 

 

by  pressing  the  ▼  button  until  “OFF”  appears.  Set  the  maximum 

 

number of days between by pressing ▲ or ▼. Range is 1– 28 days. 

 

If  the  OFF position  is  selected,  the softener  will  regenerate  based 

 

soley on the gallons capacity. 

 

STEP 4: Press 

NEXT

. Regeneration time (hour): Set the hour of  the day for 

 

regeneration  to  occur  by  using  ▲  or  ▼  buttons.  AM/  PM  toggles 

 

after 12. The default time is 2:00 am. 

 

STEP 5: Press 

NEXT

. Regeneration time (minutes): Set the minutes of the 

 

day for regeneration by using ▲ or ▼ buttons. Press  

NEXT

  to  exit 

 

Displays/Settings. Current time of day will be dislpayed. 

SET HARDNESS, DAYS OVERRIDE & REGENERATION TIME  

FIGURE 3 

FIGURE 2 

SET 

CLOCK 

NEXT 

▲ 

▼ 

REGEN 

STEP 1 

SET 

CLOCK 

NEXT 

▲ 

▼ 

REGEN 

STEP 4 

  

 

            

2:00 

AM

 

SET TIME  

SET 

CLOCK 

NEXT 

▲ 

▼ 

REGEN 

STEP 5 

STEP 3 

 

  

                

14

 

SET   

 

   

                

20

 

SET 

STEP 2 

HARDNESS 

REGEN 

 

  

            

2:00 

AM

 

SET TIME  

REGEN 

SET 

CLOCK 

NEXT 

▲ 

▼ 

REGEN 

REGEN 

DAY 

SET 

CLOCK 

NEXT 

▲ 

▼ 

REGEN 





 

       Page 4  

Содержание 7-LECS-50

Страница 1: ...ned to give you many years of trouble free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and futur...

Страница 2: ...see Page 11 connect the fitting to the plumbing system first and then attach the nut split ring and o ring Heat from soldering or solvent cements may damage the nut split ring or o ring Solder joints...

Страница 3: ...buttons AM PM toggles after 12 STEP 3 Press NEXT Set current minutes by pressing or buttons STEP 4 Press NEXT to exit SET CLOCK FIGURE 1 TO INSTALL 5 8 POLY TUBE DRAIN LINE The poly tube insert is sh...

Страница 4: ...anitation methods FIGURE 3 FIGURE 2 PLACING UNIT INTO SERVICE Make sure inlet and outlet valves are to their closed positions If using optional bypass place in bypass position Turn on main water suppl...

Страница 5: ...hammer To access the rotor unscrew the cap and lift the cap rotor and handle out as one unit Twisting the unit as you pull it out will help to remove it more easily There are three o rings one under...

Страница 6: ...per right corner This helps the drive gears mesh with the drive cap assembly The drive bracket is properly seated when it snaps under the latches on the drive back plate If resistance is felt before l...

Страница 7: ...tchet until the black o ring on the spacer stack assembly is no longer visible through the drain port Excessive force can break the notches molded into the drive back plate Make certain the main drive...

Страница 8: ...the elbow until the o ring seats Remove locking clip push down on elbow to reseat and insert locking clip DO NOT use Vaseline oils or other unacceptable lubricants on o rings A silicone lubricant may...

Страница 9: ...0 1Z Injector Assy Z Plug 5 1 V3010 1C Injector Assy C Violet 5 1 V3010 1E Injector Assy E White 5 1 V3010 1F Injector Assy F Blue 5 1 V3010 1G Injector Assy G Yellow Not Shown V3170 O Ring 011 Not Sh...

Страница 10: ...bow Male 1 5 V3163 O ring 019 1 6 V3159 01 WS1 DLFC Retainer ASY 1 7 V3162 007 WS1 DLFC 0 7 gpm for One DLFC must be used if tting is used V3162 010 WS1 DLFC 1 0 gpm for V3162 013 WS1 DLFC 1 3 gpm for...

Страница 11: ...O Ring 215 4 2 V3149 1 PVC Male NPT Elbow Item No Quantity Part No Description 1 1 H4600 3 8 Safety Brine Valve 2 2 10151 Pin 3 1 H4640 32 Float Assembly 4 1 H4500 30 50 Air Check Assembly Item No Qu...

Страница 12: ...drive forces on piston c Replace piston s and spacer stack assembly d Control valve piston not in home position d Press NEXT and REGEN for 3 seconds or unplug power source jack black wire and plug ba...

Отзывы: