LAN Power LP-2340 Скачать руководство пользователя страница 1

 

INSTALLATION MANUAL

 

LP-2340 

Internal Single Channel  PoE and Ethernet  Data Extender 

V 1.1.0 

 

 

 

 

 

LAN Power 

44240 Fremont Blvd, Fremont, Ca. 94538 USA 

Telephone: +1 (510) 275-4572 

FAX: +1 (510) 284-

2420 

Web Site Address

www.lan-power.com

           

Email: [email protected]

 

 

 

Содержание LP-2340

Страница 1: ...2340 Internal Single Channel PoE and Ethernet Data Extender V 1 1 0 LAN Power 44240 Fremont Blvd Fremont Ca 94538 USATelephone 1 510 275 4572 FAX 1 510 284 2420 Web Site Address www lan power com Emai...

Страница 2: ...it to us for repair WARNING This apparatus must be earthed Apparatus shall be connected to a mains socket outlet with a protective earthing connection To prevent fire or electric shock hazard do not...

Страница 3: ...0 meters 328 feet per unit Data rate 10 100Mbps full duplex and is compliant with standard Ethernet protocols and devices IEEE802 3af PoE at PoE compliant passes PoE power throughout the channel Dual...

Страница 4: ...4 Front view Rear view 12VDC Input Data PoE Input Data Output Data PoE Output Optional LP 2340PSU Input Data PoE Input Application Overview...

Страница 5: ...e does not exceed 100 meters 328 ft There is no on off switch when connected correctly the LP 2340 is operational and no programming is required Connections 1 Connect the Data PoE IN RJ 45 port to you...

Страница 6: ...n Transferring data at 10Mbps 100Mbps Unlit Data link is not connected Flashing green Transferring data at 100Mbps Output Indicators LED Color Indication 10Mbps Unlit Data link is not connected Flashi...

Страница 7: ...IEEE802 3af PoE compliant Full duplex operation at the rate of 100 Mbps and 10 Mbps Fully compliant with IEEE 802 3TM IEEE 802 3u and IEEE 802 3ab standards Standards Conformance IEEE 802 3af and IEEE...

Страница 8: ...hooting Symptom Corrective steps Extender does not power up 1 Verify that an approved power cable is used 2 If the extender is powered by a PoE switch or Midspan Injector make sure the switch is compl...

Страница 9: ...ing properly 5 Ensure that the input Ethernet cable is connected to the Data or PoE IN RJ 45 port 6 Verify that the PSE is connected to the Data or PoE IN port 7 Try to reconnect the same PSE into a d...

Страница 10: ...r higher 2 Using a Cat 5e 6 is recommended For further Technical Support call 1 510 275 4572 Note When calling Technical supportplease have Manufacturer Nameand PartNumbers for all devices being conne...

Страница 11: ...at www lan power com LAN Power reserves the right to make changesin specificationsand other informationcontainedin thisdocument and its web site without prior notice The reader should consult LAN Powe...

Отзывы: