background image

BOX 422 • TOWER, MN 55790 • USA • Tel (218) 753-2330 • www.lamppakuuma.com

20

InStaLLatIon

1.  Mount the unit in the position most desirable to 

your needs.

2.  Connect the two leads to the appropriate power 

source. Refer to blower name plate.

CautIon:  a  ground  wire  must  run  from  the  blower  motor 
housing  to  a  suitable  electrical  ground  such  as  a  properly 
grounded metallic raceway or ground wire system.

3.  Wiring Diagram for Model 4C565A 2-speed blow-

er only.

NOTE: IF ONLY ONE SPEED IS USED, ISOLATE THE REMAIN-
ing leaD with eleCtriCians tape Or plastiC COnneC-
tOr.

MaIntenanCe

WarnInG:  aLWayS  DISConneCt  PoWer  SuPPLy  Be-
Fore SerVICInG tHe BLoWer or WorkInG WItH tHe 
unIt For any reaSon. tHIS IS eSPeCIaLLy IMPortant 
WItH  unItS  eQuIPPeD  WItH  autoMatIC-reSet  tHer-
MaL ProteCtIon. unIt May aCtIVate WItHout Warn-
InG!

LuBrICatIon

The  motor  should  be  re-lubricated  every  6  months 
with 10 or 20 drops of SAE 10W or 20W non-deter-
gent oil (ML-type) or with electric motor oil.

NO LUBRICATION FOR 1TDR9

GeneraL

Should further servicing of the unit be necessary, re-
fer to the “exploded” view illustration as an aid in dis-
assembly and assembly procedures.

limiteD warranty

Dayton  blowers,  Models  4C004A,  4C005,  4C008B,  4C012A,  4C013A,  4C264A,  4C446,  4C447, 
4C448A, and 4C565A, are warranted by Dayton Electric Mfg. Co. (Dayton) to the original user against 
defects in workmanship or materials under normal use (rental use excluded), or one year after date 
of purchase. Any part which is determined to be defective in material or workmanship and returned 
to an authorized service location, as Dayton designates, shipping costs prepaid, will be repaired or 
replaced  at  Dayton’s  option.  For  warranty  claim  procedures,  see  “Prompt  Disposition”  below.  This 
warranty give purchaser’s specific legal rights and purchasers may also have other rights which vary 
from state to state.

WARRANTY DISCLAIMER. Dayton has made a diligent effort to illustrate and describe the products 
in this literature accurately, however, such illustrations and descriptions are for the sole purpose of 
identification, and do not express or imply a warranty that the products are merchantable, or fit for a 
particular purpose, or that the products will necessarily conform to the illustrations or descriptions.

Except as provided below, no warranty or admission of fact, expressed or implied, other than as stated 
in “LIMITED WARRANTY” above is made or authorized by Dayton, and Dayton’s liability in all events 
is limited to the purchase price paid.

Certain aspects of disclaimers are not applicable to consumer products’ e.g., (a) some states do not 
allow the exclusion or limitation of incidental or consequential damages, so the above limitation or 
exclusion may not apply to you; (b) also, some states do not allow limitations on how long an implied 
warranty lasts, consequently the above limitation may not apply to you, and (c) by law, during the 
period of this Limited Warranty, any implied warranties of merchantability or fitness for a particular 
purpose applicable to consumer products purchased by consumers, may not be excluded or other-
wise disclaimed.

PROMPT DISPOSITION. Dayton will make a good faith effort for prompt correction or other adjustment 
with respect to any product which proves to be defective within warranty. For any product believed to 
be defective within warranty, first write or call dealer from whom product was purchased. Dealer will 
give additional directions. If unable to resolve satisfactorily, write to Dayton at address below, giving 
dealer’s name, address, date and number of dealer’s invoice, and describing the nature of the defect. 
If product was damaged in transit to you, file claim with carrier.

DAYTON ELECTRIC MFG. CO., 5959 W. HOWARD ST., CHICAGO, ILLINOIS 60648

FORM 5S2520
04040

MODELS 4C004A, 4C005, 4C006B, 4C012A, 4C013A, 

4C284A, 4C446, 4C447, 4C448A, 4C565A, AND ITDR9

BLaCk (HIGH SPeeD)

WHIte (CoMMon)

reD (LoW SPeeD)

Green (GrounD)

Motor

trouBLe SHootInG CHart

symptOm 

pOssible Cause(s) 

COrreCtiVe aCtiOn

Excessive Noise. 

1. Blower wheel contacting housing. 

1. Realign or replace.

 

2. Foreign material inside housing. 

2. Clean.

 

3. Leak in duct work. 

3. Repair.

 

4. Loose duct work. 

4. Secure properly

Insufficient air flow. 

1. Leaks in duct work. 

1. Repair

 

2. Dampers and/or registers closed. 

2. Open.

 

3. Obstruction in system. 

3. Remove

 

4. Clogged Filters. 

4. Clean or replace.

Unite fails to operate. 

1. Blown fuse or open circuit breaker. 

1. Replace fuse or reset circuit breaker.

 

2. Defective motor. 

2. Replace.

 

3. Automatic-reset thermal protector “tripped”. 

3.  Check for high (or low voltage input or ambi-

ent temperatures in excess of 40° C (104° F).

 

4. Motor improperly wired. 

4. Re-wire.

Содержание Kuuma Vapor-Fire 200

Страница 1: ...tion Lamppa Manufacturing Distributing Co Inc Read all instructions and rules for safe operation carefully before starting the installation Follow all state and local codes and ordinances BOX 422 TOWE...

Страница 2: ...s Raking Coals Into Ash Pam Adjusting Door Latch Adjusting Door Hinges Airtight House How to Remedy Problem Typical Hot Air Hook up Disposal of Ashes Safety Considerations Creosote Formation Common Ch...

Страница 3: ...nace freight prepaid to the plant at no cost to Lamppa Manufacturing and Distributing Co Inc This warranty does not apply to any heat shields brick holders or parts such as seals latches hing es other...

Страница 4: ...metric draft control field 6 RC BT as described and illustrated on page 12 and 13 also see Figures 21 and 22 7 WE SUGGEST THAT A LICENSED ELEC TRICIAN BE HIRED TO DO ALL YOUR ELECTRICAL CONNECTIONS Se...

Страница 5: ...el 218 753 2330 www lamppakuuma com 5 Figure 16 Figure 3 Figure 2 Fire door Front Back Primary air openings Figure 4 Grate U brick retainer Typical hot air hook up Install gasket provided Install filt...

Страница 6: ...Installation and Figure 18 of Masonry Chimney note roof clearance in ac cordance with NFPA 211 COMMON CHIMNEY PROBLEMS In order to have a proper operating Solid Fuel Heat System the chimney must be ca...

Страница 7: ...Restrictions The flue pipe is connected to the chimney with too many elbows reducing the draft chimney can provide 8 Multiple Venting When more than one 1 devise vents into the same chimney flue When...

Страница 8: ...o that if any creosote is formed as a natural by product of combustion it will run back towards the furnace and not run through the joint to the outside of the smoke pipe The sec tion of pipe tee hold...

Страница 9: ...light bind As you close the door making sure it is not too tight tighten the screws Figure 9 Figure 13 Figure 14 Door handle Door latch Adjust screw Hinge pin Hinge piece Door frame Fire door Pivot sc...

Страница 10: ...ls have been raked forward the back half of the fire chamber floor should be free of any hot coals If the logs are added when there are hot coals in the back the logs will ignite and burn from the bac...

Страница 11: ...perature in the fire chamber Tighten door adjustment to eliminate door leaks See sticker on the Electronic Draft Controller BOX 422 TOWER MN 55790 USA Tel 218 753 2330 www lamppakuuma com 11 WARNING L...

Страница 12: ...e and clear of any ash es The long narrow slit between the two square holes MUST be kept clean see Figure 2 DISPOSAL OF ASHES Ashes should be placed in metal container with a tight fitting lid The clo...

Страница 13: ...ODSHAVINGS PAPER SCRAPS DRIED CHRISTMAS TREES COAL GARBAGE TIRES OR OTHER BURNABLE PRODUCTS Important DURINGNORMALOPERATION FIRINGDOOR AND ASH DOOR MUST BE KEPT TIGHTLY CLOSED AIRLEAKAGEWILLCAUSELOSSO...

Страница 14: ...ront lift off hood for more gravity heat flow For further information on using your heater safely obtain a copy of the National Fire Protection Asso ciation publication Using Coal and Wood Stoves Safe...

Страница 15: ...Gas 93 300 BTU gallon Butane Gas 100 671 BTU gallon Electricity 3 413 BTU kilowatt hour WOOD BURNING FACTS BE AWARE OF CREOSOTE BUILD UP WHEN BURNING WOOD Wood burning equipment will give you trouble...

Страница 16: ...hich you don t want 4 You should install another limit control switch in your bonnet at approximately the same height as to where the KUUMA duct enters the bonnet this is necessary so the control can...

Страница 17: ...holes in the back of the stove so the filter box can be screwed securely to the hood MAKE SURE THE HOLES DRILLED ARE THE CORRECT SIZE SO THAT THE SCREWS WILL SECURELY HOLD THE BOX 7 Re install secure...

Страница 18: ...ering the fire chamber for example as follows A At start up all three lights are on and also again at the end of the burn cycle this indi cates that the shutter is wide open B As the fire gradually in...

Страница 19: ...sive leakage G Cleanout door is open H The primary opening on your KUUMA is filled with ashes I House is too air tight To correct this see Figure 15 J Wood is too wet K Avoid 90 degree elbows and hori...

Страница 20: ...orm to the illustrations or descriptions Except as provided below no warranty or admission of fact expressed or implied other than as stated in LIMITED WARRANTY above is made or authorized by Dayton a...

Страница 21: ...8710 0028 4 Gasket 0912 0167 0912 0167 0912 0167 0920 0069 0912 0167 0912 0167 0912 0167 5 Outlet box cover 8591 6482 8591 6482 8591 6482 8591 6482 8591 6482 8591 6482 6 Washer 8 8 8 8 8 8 8 8 8 8 7 N...

Страница 22: ...BOX 422 TOWER MN 55790 USA Tel 218 753 2330 www lamppakuuma com 22...

Страница 23: ...BOX 422 TOWER MN 55790 USA Tel 218 753 2330 www lamppakuuma com 23...

Страница 24: ...Lamppa Manufacturing Distributing Co Inc BOX 422 TOWER MN 55790 USA Tel 218 753 2330 www lamppakuuma com 05 2012...

Отзывы: