The viewing distance is correct when the complete visual field can be seen through 
both eyepieces and both views combine to produce the effect of a single field of vision. 

 

  

The viewing distance should be individually set for each user. 
 
 

 

5-3

  

FOCUSING 

 

  

Mount the welding hand-piece in the supporting arm. Make sure that the hand-piece 
has an electrode inserted and is correctly positioned. 

 

 

Turn the rotary knob - focus (10) until a focus setting is achieved, which is midway 
between the min. and max. focus setting. 
 

 

 

Adjusting the height of the microscope head mount: 
Hold the microscope head (8) in one hand, (avoid touching the microscope lens). With 
the other hand loosen the retaining screw of the microscope head mount (9). The 
microscope head can now be freely adjusted in height. 

 

 

Look through the eyepieces and slide the microscope head up or down on the bearing 
rod until the object is in focus.  

 

 

Tighten the retaining screw of the microscope head mount again. 

 

 

Ensure a sharp image by adjusting the rotary knob - focus (10).  

 

5-4 

DIOPTER SETTINGS 

 

 

The ring for dioptric adjustment (2) is located on the left eye-piece tube (3). In the 
normal position, the lower part of the sleeve is aligned with the marking on the eye-
piece tube. 

 

 

 
When a user’s eyes have differing strengths of vision: 

 

 

With only the right eye open, look through the right eye-piece (1) and set the focus 
using the rotary knob - focus (10). 

 

 

Now, with only the left eye open, look through the left eye-piece and adjust the focus by 
turning the dioptric adjustment (2) on the left eye-piece tube (3) until the viewed object 
is in focus. 

 

 

 

 

 

CARE AND MAINTENANCE 

 

 

Under normal working conditions, the stereo microscope “USM” needs only a minimum 
of maintenance and care. However there are a few vital points, which when observed will 
ensure that the device gives lasting service in the years to come. 

 

 

After finishing working with the “USM”, always cover it with its dust protection cover. 

 

 

Every so often please check all cables and plugs to make sure that they are not 
damaged. 

 

 

Every now and then, clean the device with a soft cloth.  

 

 

SHOULD ANY MAINTENANCE OR REPAIRS BE NECESSARY THAT ARE NOT 
DESCRIBED IN THIS MANUAL, PLEASE CONTACT YOUR LOCAL DEALER. 

 

6-1  MAINTANENCE OF THE OPTICAL COMPONENTS 

 

  

Do not try to dismantle the optical components. For repairs that are not described in this 
manual, please consult your local dealer or the Lampert Service Centre. 

Содержание USM

Страница 1: ...and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by improper use or operatio...

Страница 2: ...tting the viewing distance 7 5 3 Focussing 8 5 4 Dioptre settings 8 6 CARE AND MAINTENANCE 6 1 Maintenance of the optical components 8 6 2 Maintenance of the electrical components 9 7 TROUBLE SHOOTING...

Страница 3: ...her application of the appliance other than the above stated is prohibited It is prohibited to use this apparatus out of doors Use only in dry surroundings 2 INTRODUCTION Arc welding without protectiv...

Страница 4: ...st be shut down and removed from the power supply it must also be secured against accidental re operation or activation It is likely and can be expected that a safe operation of the device is no longe...

Страница 5: ...parts must not be put together using excessive force Mount the bearing rod 11 to the base plate 13 using the bolt that is included tighten it with an open ended spanner Place upright on a clean flat a...

Страница 6: ...n the welding device will run a self test During the self test the LCD glare protection filter Shutter 6 will change from its clear setting to its dark setting and back again Each time the machine is...

Страница 7: ...CD glare protection filter Shutter 18 Rod for pitch adjustment 5 INSTRUCTIONS FOR USE 5 1 FIRST STEPS Adjust the height and position of the supporting arm 12 so that when both hands are resting on the...

Страница 8: ...t eye piece tube 3 In the normal position the lower part of the sleeve is aligned with the marking on the eye piece tube When a user s eyes have differing strengths of vision With only the right eye o...

Страница 9: ...S Warning Danger of glare never look directly into the LED light or its reflections Caution Only operate the LED light when the LED module is mounted in the supporting arm of the hand piece Changing t...

Страница 10: ...h the other 13 Always hold the microscope upright 8 TECHNICAL DATA 8 1 TECHNICAL INFORMATION MICROSCOPE LCD glare protection filter and LED light module For use only in conjunction with PUK U3 precisi...

Страница 11: ...vice may only be opened by a trained and qualified technician Text pictures and illustrations represent the technical stand at the time of printing we reserve the right to make changes as necessary 9...

Страница 12: ...ns of the above mentioned directive including any amendments hereof that were valid at the time of declaration Relevant EC guidelines According to low voltage directive 2006 95 EG According to EMV ele...

Отзывы: