11
5-2 Programming
(Only "PUK 3s professional plus")
RECALLING STORED SETTINGS (Program slot 1 – 10)
Apart from the 5 pre-programmed memory slots, this feature brings the
possibility to personalise and store the users own welding parameter
settings, into 5 additionally available memory slots. These settings can
then be recalled at a moments notice.
Please note:
The preset parameters represent a recommended
guideline for work. When working on especially thin or intricate
constructions, we advise using the following method to avoid damage to
the work piece: Start welding with a lower power and then readjust the
power if necessary, gradually increasing it until the correct setting is
achieved.
By pressing (short) the button – program memory (3) and then releasing
it, the individual memory slots can be accessed.
STORING OF INDIVIDUAL SETTINGS (memory slots 6 - 10)
Press the button – program memory (3)
(long – ca. 1 sec.)
and then
releasing it, the process for storing the current user settings is initiated.
Press the button – program memory (3)
(short)
and then releasing it, the
memory slot can be selected in which the settings are to be saved.
(Program slot 6 – 10)
Press the button – program memory (3)
(long – ca. 3 sec.)
and then
releasing it, the settings are saved into the selected slot. The display will
show the notice “Settings stored. Please enter the name of the program”.
Now the memory slot can be given a name (up to 10 characters).
By turning the rotary knob – welding power (6), the icon (number, letter),
in the selected character, can be changed.
To select the next character in the row, press and release the rotary
knob – welding power (6)
Finally, to store the settings and name into the selected memory slot,
press and release the rotary knob – Impulse length / welding time (5).
The display will show the notice “Your text was stored” the programming
process is now completed.
Please note:
If the user tries to save a set of parameters that is identical
to one that is already stored (or identical to one of the pre-programmed
settings), the display will show the following error notice. “Settings
identical to program – X Settings not stored!”. This is to avoid the
“blocking” of a memory slot with a duplication of already stored
information.
In this case the memory slot, where the original setting is stored, will
blink. The process can then be cancelled by pressing the rotary knob –
welding power (6).