SYMBOL USAGE 

 

 

Warning! 

 

 

“Warning!” indicates a potentially hazardous situation which, if not avoided, could result 
in death or serious injury. This signal word is not used for property damage hazards 
unless personal injury risk appropriate to this level is also involved. 

 

 

Caution! 

 

 

“Caution!” indicates a potentially hazardous situation which, if not avoided, may result in 
minor or moderate injury. It may also be used to alert against unsafe practices that may 
cause property damage. 

 

 

Note! 

 

 

“Note!” indicates a situation which implies a risk of impaired welding result and damage 
to the equipment. 

 

 

Important! 

 

 

“Important!” indicates practical hints and other useful special-information. It is no signal 
word for a harmful or dangerous situation. 

 

 

 

 

GENERAL APPLICATION 

 

  

The observation or microscoping of objects via the microscope eyepiece and work area 
illumination. 

 

  

The MEZZO may only be used together with the „PUK“-Precision Welding Device. 

 

  

The MEZZO may only be used if set up according to the instructions. 

 

  

Any usage other than herein specified is prohibited. 

 

  

Operation in outdoor areas is prohibited. Use in dry room areas only. 

 

 

 

 

INTRODUCTION 

 

  

Arc Welding without protective equipment is dangerous and may result in a painful 
inflammation of the cornea as well as irreversible cataracts. The MEZZO with integrated 
LCD eye-protecting filter offers reliable shield against these hazards and 

permanently 

protects 

the eyes from UV/IR-Rays, sparks and splashes in both its clear setting 

(Luminescence DIN3) to its dark setting (Obscurity DIN11). The protection level of the 
filter is constructed in such a way, that a dazzling from the glare of the electric arc is 
avoided. The MEZZO may only be used in conjunction with PUK welding devices. Shortly 
before ignition of the electric arc, the PUK's electronic control unit automatically activates 
the filter and switches from its clear setting (Luminescence DIN3) to its dark setting 
(Obscurity DIN11). The filter then lightens up again immediately after the electric arc 
ceases. 

 

 

 

 

 

 

Содержание MEZZO

Страница 1: ...y qualified personnel and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by imp...

Страница 2: ...5 2 SETTING THE VIEWING DISTANCE 7 5 3 FOCUSSING 7 5 4 DIOPTRE SETTINGS 8 6 CARE AND MAINTENENCE 6 1 MAINTENANCE OF THE OPTICAL COMPONENTS 8 6 2 MAINTENANCE OF THE ELECTRICAL COMPONENTS 9 7 TROUBLE S...

Страница 3: ...Precision Welding Device The MEZZO may only be used if set up according to the instructions Any usage other than herein specified is prohibited Operation in outdoor areas is prohibited Use in dry room...

Страница 4: ...e device and secure it against unauthorised use It is clear that a hazardous conditions are present when the device shows visible damage or or when functional errors occur if it no longer functions pr...

Страница 5: ...of the stereo microscope very carefully The stereo microscope s individual parts and elements should not be assembled too forcefully Mount the bearing rod 11 to the base plate 13 with the attachment...

Страница 6: ...6 4 2 DESCRIPTION OF THE OPERATING ELEMENTS fig 1...

Страница 7: ...rt in such a way that a workpiece can easily by hand be lead to the tip of a mounted tool holder Both hands or heels of the hand should be able to easily bear on the base plate Switch on the main ligh...

Страница 8: ...ENCE The mezzo needs under ordinary working conditions only minimal care and maintenance Remembering a couple of points is crucial though to ensure proper functioning and a long life for your welding...

Страница 9: ...supporting arm of the hand piece Remember that the module should fit flush with the underside of the supporting arm 7 TROUBLE SHOOTING PROBLEM CAUSE SOLUTION 7 1 PROBLEMS WITH ELECTRICAL COMPONENTS A...

Страница 10: ...d on to the tripod rod 11 of the stereomicroscope with the other hand hold on to the base plate 13 Keep the stereomicroscope always upright 8 TECHNICAL DATA 8 1 TECHNICAL DATA MICROSCOPE Optical view...

Страница 11: ...rotection system MEZZO conforms to the conditions set forth in the below named guidelines including any changes made up to the time of declaration Relevant EEC guidelines According to low voltage guid...

Отзывы: