Fully screw the “Screw pin” into the tapped hole on the
top face of the “Upper arm”. (Use a wrench (10).)
Set the “Gas spring” to the “Screw pin” as shown in the
figure on the right side.
Installing the gas spring
(arm side)
5
6
Fix the “Positioning unit” to the back of the door with the supplied
screws so that the
mark can be seen as below.
Fixing positioning unit
Attach “Pile seal” to the (edge of the door) shown as below.
Attaching pile seal
Positioning unit
Pile seal
Back of the door
Install the handle to the
front of the door.
Installing the handle
Handle
Use binds or truss M8
screws appropriate for
the thickness of the door.
(Thickness of door
+ 5 mm or more)
Front face of door
E-ring
Spring washer
Upper arm
Screw pin
Flat washer
Gas spring
Ceiling
Floor surface
Working dimensional drawing of door
Back face of door
Reference of arm
hinged side
Cabinet inside
Mounting hole for handle 2-*9, through hole
Prepared hole for 4.5
self-tapping screw, 20 pos.
59
30
188
946
Overlaying allowance (25)
Overlaying
allowance (25)
Cabinet width (from 800 to 750)
70
Cabinet height – 490
70
36
685
110
378
110
53
Door width = (including right and left overlaying allowances)
Door height = Cabinet Upper and lower overlaying allowances
20
30
50
170
Cabinet height
Overlaying
allowance
Overlaying
allowance
Loosen the screw on “Gas spring holder” so that the
holder can be moved.
Move the arm to the stopper of “Upper arm” until it
contacts with the end of cabinet (open position), move
the “Gas spring holder” along the rail, and install the gas
spring to the screw pin as below.
Installing the gas spring
(roof side)
Fixing screw
Gas spring holder
Channel rail
Gas spring
Flat washer
E-ring
Tighten the screw on gas spring holder while the stopper
of the “Upper arm” is coming in contact with the end of
cabinet.
Tightening gas spring holder
Stopper
Open position
Return the upper arm in close position, and attach the
clear cushion rubber to the center of the “Stopper of
upper arm” as the drawing.
Attaching clear cushion rubber
Upper arm stopper
Upper arm
Clear cushion rubber
Installing Parts to Door
4
The door is not supplied.
Set core material of which strength is enough for secure tightening of self-
tapping screws to the locations that parts are to be installed.
CAUTION
Dimensions in lateral direction are determined with the (width) of the cabinet (wooden frame) regarded as the
reference position. If the door end face is regarded as the reference position, add the overlaying allowance.
CAUTION
Be sure to install the handle to
the location closer to the hinge
than the center of the door.
CAUTION
The figure show in
[ ]