background image

2

SETUP

BEFORE FIRST USE

 

¬

Fully charge battery using the Spin Touch USB cable and adapter plug in AC 

outlet.

 

¬

Ensure your Spin Touch has the latest firmware. A USB connection to a 

Windows® PC is required.

1.  Download and install the WaterLink Connect 2 application for Windows at 

softwarecenter.lamotte.com

.

2.  Plug meter into the computer with the provided USB cable and launch 

WaterLink Connect 2 application from the Start Menu.

3.  A prompt will appear if firmware updates are available. Select Update. 

Testing and data transfer will not be possible until firmware has been 

updated.

METER 

1.  The meter can be powered from an AC outlet, a computer or the internal battery.
2.  Use the USB cable and the adapter to plug the meter into an AC outlet. 
3.  Use the USB cable to connect the meter to the USB port of a computer.

CHARGE THE BATTERY

1.  Use the USB cable and the adapter to plug the meter into an AC outlet or use 

the USB cable (included) with a car charger (not included) to charge the battery. 

(Anker PowerDrive 2, DC 12/24V, 5V = 4.8A, Part Number A2310 recommended.)

2.  The battery icon on the screen will show the battery status. Charge the battery 

until the battery indicator is full.

FIRMWARE UPDATES

  Occasionally, the firmware in the Spin Touch will require 

updates. A USB connection to a Windows PC is required. To do so:
1.  Visit 

softwarecenter.lamotte.com

 and download the WaterLink Connect 2 

application for Windows.

2.  Plug the Spin Touch into the computer using the included USB cable. 
3.  Open the WaterLink Connect 2 desktop application and wait for the update to 

complete.

Once the update is complete, it is safe to close WaterLink

 

Connect 2 and unplug 

the lab. After updating firmware it is recommended that the LED and Calibration 

procedures be performed..
NOTE: When a prompt to update the firmware is received, the options Update Now or 

Remind Me Later will be displayed. If Remind Me Later is chosen, the update prompt 

will be displayed again in 23 hours. Or, to update the firmware at any time, open 

WaterLink Connect 2, go to Settings>Service Settings>Get Updates.

PC CONNECTION  

When the WaterLink Spin Touch is connected to 

a computer via USB, the onboard touchscreen becomes disabled 

and operation of the lab is performed using the WaterLink Connect 

2 application for Windows. This application is available for free at 

softwarecenter.lamotte.com

. Via the WaterLink Connect 2 desktop 

application, results from the Spin Touch can be transferred to a water 

analysis program such as WaterLink Solutions

.

DEVICE CONNECTION  

The WaterLink Spin Touch supports connections to a 

Windows based PC (over USB) and to Android and iOS mobile devices (via 

Bluetooth).

CONNECTING VIA USB

  Using the provided USB cable, the WaterLink Spin Touch 

can be connected to a Windows based PC. Before connecting a meter via USB, 

download and install the free WaterLink Connect 2 Windows application from 

softwarecenter.lamotte.com

. When the WaterLink Spin Touch is connected to the 

PC via USB, the onboard touch screen controls will be disabled and operation of 

the meter is performed using the WaterLink Connect 2 application. LaMotte offers 

robust water analysis programs as well, such as WaterLink Solutions, to collect test 

results and offer detailed treatment recommendations. Learn more about LaMotte 

software products at

 

softwarecenter.lamotte.com

.

CONNECTING VIA BLUETOOTH

  The WaterLink Spin Touch is capable of 

connecting to a Bluetooth enabled device, such as a phone or tablet. The Spin Touch 

is also compatible with a BLE Mobile Printer [Code 5-0067]. Other Bluetooth printers 

are not supported. It is not necessary to pair the Spin Touch to the Bluetooth enabled 

device. Barriers to wireless signals can reduce the range of wireless devices. The 

WaterLink Spin Touch will work best if there are no walls between it and the receiving 

devices.
Transferring results over Bluetooth to a mobile device requires that a mobile app is 

installed on the device and an active account for the associated software program. 

For example, with an active WaterLink Solutions account and the WaterLink 

Solutions mobile app on a phone or tablet, results can be transferred from the meter 

into the application. Mobile apps for LaMotte software products are available on 

iTunes® (iOS® devices) and Google Play (for Android

TM

 devices). Learn more about 

LaMotte software products at 

softwarecenter.lamotte.com

.

To transfer results from the WaterLink

 

Spin Touch to a LaMotte software product 

mobile app:
1.  Log into the LaMotte software product mobile app.
2.  Search for a customer or Site record. You may need to create one before you can 

begin testing.

3.  Start a Water Test in the mobile app.
4.  Perform a water test from the Spin Touch onboard touchscreen normally. The 

Spin Touch and the Bluetooth enabled mobile device will connect automatically. 

5.  When the connection is available the 

 will light on the touch screen. When the  

is dim, the meter and device are not connected. Tap the 

 

to transfer results 

to the mobile app.

Whenever the 

 appears on the touch screen the Spin Touch is capable of 

connecting to the BLE Mobile Printer (5-0067). The 

 button will be highlighted 

when connected and dim when not connected. 
The Spin Touch cannot connect to both mobile device and the printer at one time. 

(See Save, Print and Send Test Results)

FILLING: Single-Use Disks 

When the syringe is placed in the water sample, and 

the plunger is pulled all the way up, the syringe will 

hold more than enough water sample to adequately 

fill the disk. Hold the syringe vertically and insert 

the tip into the fill hole in the disk. Press the plunger 

slowly and smoothly to fill the disk.

1.  Fill the disk using slow, even pressure. The 

sample water will fill the spaces between the 

baffles in a counterclockwise order. Each space 

will fill from the bottom to the top. Sample water 

should be added until the sample water in the 

fourth chamber fills 

to the top 

of the chamber 

slightly past

 the embossed fill line. 

It is OK to fill 

slightly past the fill line.

Correct Fill

(Fill line) 

2.  Do not overfill the disk. If the disk is overfilled, 

sample water will flow out of the overflow hole in 

the center of the disk. The disk is not leaking. Dry 

the disk and run the test.

Overfilled 

(Dry SpinDisk before placing in meter)

3.  Do not under fill the disk. If the disk is under 

filled, the reagent chambers will not fill entirely 

and results will be inaccurate.

Underfilled 

4.  Do not introduce air bubbles into the disk. The 

reagent chambers will not fill entirely and results 

will be inaccurate. As soon as a bubble starts 

to form, pull back on the plunger to draw the 

bubble out of the disk. Begin the filling process 

again.

Air 

Bubble

5.  Wet disks should be dried thoroughly with a lint 

free wipe. The disk should be handled by the 

edges.

6.  Disks should be filled and used within 10 

minutes. They cannot be filled ahead of time.

For filling and troubleshooting tips go to: 

lamotte.com/spin_support

FILLING: Multiple-Use Disks

When the syringe is placed in the water sample, and 

the plunger is pulled all the way up, the syringe will 

hold more than enough water sample to adequately 

fill the disk. Hold the syringe vertically and insert 

the tip into the fill hole in the disk. Press the plunger 

slowly and smoothly to fill the disk. Sections do not 

have to be filled in order. The meter will detect which 

section was most recently filled.

1.  Fill any unused section of the disk using slow, even 

pressure. Add the sample water until the Blank 

Chamber is full and the Over Flow Chamber is 

partially filled. 

Correct Fill 

Blank 

Chamber

Over Flow 

Chamber

2.  Do not overfill the disk. If the disk is overfilled, 

sample water will flow out of the vent hole in the 

center of the disk. If this happens sample water 

may flow into a reagent chamber prematurely and 

results will not be accurate. Begin a new test in 

the next chamber.

Overfilled

(Dry SpinDisk before placing in meter)

Blank 

Chamber

Over Flow 

Chamber

Содержание WaterLink SpinTouch 3580-AU

Страница 1: ...SF ANSI CAN 50 2023 LaMotte Company All Rights Reserved For Code 3580 AU 3581 AU 05 09 2023 Scantoaccess download andprint theSpinTouchQuickStartGuide WARNING only use the USB cable and wall adapter t...

Страница 2: ...a mobile device requires that a mobile app is installed on the device and an active account for the associated software program For example with an active WaterLink Solutions account and the WaterLink...

Страница 3: ...at a time Auto Save Tests must be disabled If Auto Save Tests is disabled will be highlighted on the Test Results screen After the test has been run tap to save the results for that water sample to th...

Страница 4: ...d at low battery power without connecting it an AC power source the meter will go into an auto shutdown mode In this mode the meter will be locked until meter is connected to an AC source and the batt...

Страница 5: ...k Free Chlorine Bromine Free Chlorine Bromine Total Chlorine Total Chlorine Chlorine Bromine pH Alkalinity Code4335 Series601 pH Free Chlorine Bromine Alkalinity pH Free Chlorine Bromine Alkalinity Bl...

Страница 6: ...IMPORTANT DonotattempttoseparatethecomponentsoftheMeterCheckDisk Code1705 1705 EU TheMeterCheckDiskconsistsofadiskwithapermanently attachedcover DonotfilltheMeterCheckDiskwithwater Waterisnotusedinth...

Страница 7: ...emergency line for ChemTel at 1 800 255 3924 USA Canada Puerto Rico For locations outside of the North American continent call 813 248 0585 collect Ensure that the protection provided by this equipmen...

Отзывы: