PROCEDURE C - REGENERATION OF RESIN IN TOP CHAMBER

Follow manufacturers’ insstructions for regeneration of media. Cation exchange resin
may be regenerated in the following manner. NOTE: Due to build up of air pressure, it
is not possible to regenerate both chambers at the same time. Follow steps 1-8 to
regenerate top chamber, then procedure D to regenerate bottom chamber.

Clean

threaded area

completely

and replace

black plug in

top of

softener.

6.

At this point the resin in the top chamber should be completely

regenerated.

9.

Wash resin with

approximately 1

gallon of tap water.

8.

Attach adapter

to faucet.

7.

Remove

black plug

from top of

softener.

2.

Prepare salt

solution by

dissolving about

½ pound of salt

(sodium

chloride) in 1

quart of water.

1.

Allow to stand for about 30

minutes.

4.

30

MINUT

ES

Clamp outlet

tube.

Add salt

solution until

top chamber is

completely

full.

3.

Unclamp outlet tube

and allow salt

solution to run to

waste.

5.