COMPUTER CONNECTION

 

„

OUTPUT

USB

 

„

COMPUTER CONNECTION

USB Type A, USB mini B, Order Cable Code 1720-01.

 

„

WATERLINK CONNECT 2

The meter may be interfaced with any Windows-based 64-bit computer 

by using the LaMotte WaterLink Connect 2 program and a USB cable. The 

program will store test information and results in a local database and allow 

for exporting this data to a comma separated value (CSV) file. The meter 

will send the following data: time/date stamp, name of test, sample value, 

sample units, meter name, and location. To download WaterLink Connect 2 

go to http:// softwarecenter.lamotte.com/. Select “WaterLink Connect 2 FREE 

Download”.

BATTERY

 

„

BATTERY/AC OPERATION

The colorimeter may be operated on battery power using a USB wall adapter 

or USB computer connection. If using the meter as a bench top unit, use the 

wall adapter if possible to extend the battery life. The meter will remain on 

when the USB adapter is used.
To charge the lithium ion battery with the wall adapter, plug the smaller end of 

the USB cable (USB mini B connector) into the meter and the larger end of the 

USB cable (USB type A connector) into the wall adapter. Plug the wall adapter 

into an AC outlet. Reinsert the rubber USB port plug after charging. Failure 

to insert the USB port plug when the meter is not connected to a computer 

by USB or actively charging by USB could result in damage to internal 

components.
To charge the battery from a computer, plug the smaller end of the USB cable 

(USB mini B connector) into the meter and the larger end of the USB cable 

(USB Type A connector) into a USB port on a computer. Reinsert the USB port 

plug after charging. Failure to insert the USB port plug when the meter is not 

connected to a computer by USB or actively charging by USB could result in 

damage to internal components.
The battery icon will show no bars and flash when the unit first turns on. Then 

the indicator will indicate the battery status by showing 0, 1, 2, 3, or 4 bars.  

It will take 6 hours to fully charge a low battery. The battery icon will flash 

when the battery is charging. The battery icon will show four bars and stop 

flashing when it is fully charged. The charging circuit will automatically switch 

to a float charge when the battery is fully charged. The charger may remain 

connected. Some computers will NOT supply power to their USB ports during 

standby operation. The wall adapter will charge the unit continuously. Storing 

the meter above ambient room temperature will decrease the battery charge 

more quickly than storage at room temperature. If the meter does not turn 

on, it means that the battery is at a very low charge. Charging the battery with 

www.

.com

[email protected]

1.800.561.8187

Содержание DC1500 CHLORINE

Страница 1: ...DC1500 OZONE Ozone Colorimeter Kit Code 3249 www com information itm com 1 800 561 8187...

Страница 2: ...g Power Save 12 Setting Backlight Time 13 Selecting A Language 14 Looping Menus 15 Computer Connection Output 16 Computer Connection 16 Battery Battery AC Operation 16 Battery Replacement 17 Maintenan...

Страница 3: ...ry 22 General Precautions 22 Safety Precautions 23 Limits of Liability 23 Specifications 24 CE 25 IP67 25 Warranty 25 Trouble Shooting Guide Error Messages 26 Stray Light 26 Troubleshooting Guide 27 w...

Страница 4: ...view or print a Safety Data Sheet SDS for these reagents go to www lamotte com Search the four digit reagent code number listed on the reagent label in the contents list or in the test procedures Omi...

Страница 5: ...fectant in many artificial habitats APPLICATION Drinking pool and aquatic waters RANGE 0 00 0 40 ppm Ozone METHOD Ozone rapidly and stoichiometrically decolorizes Indigo Trisulfonate under acidic cond...

Страница 6: ...ndigo Blue Stock Solution 3989 to the amber glass bottle Cap and mix 3 Use the 1 0 mL transfer pipet 2 2170 and pipette pump 30527 to add 1 0 mL of HR Reagent 3988 to each of 2 clean colorimeter tubes...

Страница 7: ...gainst inside of the prepared tube Slowly depress plunger and fill to the 10 mL line and cap This is the Sample Tube NOTE Do not shake or invert the sample 8 Fill the second prepared tube 0967 to the...

Страница 8: ...must be made fresh each week If reagent is refrigerated it may be kept up to 3 weeks NOTE Zeroing the meter with sample water or an empty chamber will result in an error when reading reacted samples...

Страница 9: ...elect Set Clock The year is displayed Press or to scroll to the appropriate character Press ENTER to select the character The month day hour format hour minute second AM PM will be dislpayed Repeat fo...

Страница 10: ...l to Logging Editing Menu Set Clock Logging Factory Setup Set Power Save 12 00 00 001 500 2 Press ENTER to select Logging Logging Display Test Log Logging Enabled Logging Disabled Erase Log 12 00 00 0...

Страница 11: ...or to scroll to Set Power Save Editing Menu Set Clock Logging Factory Setup Set Power Save 12 00 00 001 500 2 Press ENTER to select Set Power Save Set Power Save Disable 5 Minutes 15 Minutes 30 Minute...

Страница 12: ...he more frequently the battery will have to be charged if the USB Wall Adapter is not being used 1 From the Editing Menu press or to scroll to Backlight Time Editing Menu Logging Factory Setup Set Pow...

Страница 13: ...scroll to desired language Select Language English Spanish French Portugese 12 00 00 001 500 4 Press ENTER The screen will display Storing for about 1 second and the meter will return to the Editing M...

Страница 14: ...ction The diagrams below demonstrate a looping menu AND SO ON AND SO ON AND SO ON THIRD TO LAST LAST CHOICE LAST CHOICE SECOND TO LAST AND SO ON AND SO ON LAST CHOICE TESTING MENU TESTING MENU TESTING...

Страница 15: ...SB port plug when the meter is not connected to a computer by USB or actively charging by USB could result in damage to internal components To charge the battery from a computer plug the smaller end o...

Страница 16: ...t backlight use The unit consumes three times the normal power when the backlight is on Set the backlight time option to 10 seconds or select Button Control and keep the backlight off BATTERY REPLACEM...

Страница 17: ...0 faxing 410 778 6394 or emailing tech lamotte com Often a problem can be resolved over the phone or by email If a return of the meter is necessary attach a letter with the return authorization number...

Страница 18: ...ypad These allow the user to select options from the menu driven software to directly read test results or to review stored results of previous tests in the data logger The menus can be displayed in s...

Страница 19: ...he bottom The header displays the title of the current menu The footer line displays the time and the date the data logger status and the battery status The menu selection window is in the middle of t...

Страница 20: ...messages or the LaMotte logo is displayed The top two lines of the display are used to display information in a large easy to read format The menus work in the same way as previously described but two...

Страница 21: ...e allowed to air dry in an inverted position to prevent dust from entering the tubes Dry tubes should be stored with the caps on to prevent contamination After a tube has been filled and capped it sho...

Страница 22: ...procedures until the result falls within the range of the calibration Multiply the test result by the dilution factor For example if 10 mL of the sample water is diluted with three 10 mL volumes of d...

Страница 23: ...outside the North American Continent 813 248 0585 call collect Be prepared to supply the name and four digit LaMotte code number found on the container label or at the top of the SDS or in the content...

Страница 24: ...tomatic wavelength selection Languages English Spanish French Portuguese Italian Chinese Japanese Temperature Operation 0 50 C Storage 40 60 C Operation Humidity Range 0 90 RH non condensing USB Port...

Страница 25: ...344 3100 for a return authorization number or visit www lamotte com for troubleshooting help The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in...

Страница 26: ...to Calibrate and press ENTER to view the result The concentration is only an approximation Press EXIT and continue testing Note If EXIT is not pressed the meter will calibrate on the over range resul...

Страница 27: ...r Shut Down Low Batt Shut Down Battery is too low to operate the unit Charge battery or use USB wall computer adapter Overrange Sample is outside of acceptable range Dilute sample and test again Unusu...

Отзывы: