Lower gasket 

 

Rubber horseshoe 

 

Metal horseshoe 

 

Fixing nut 

 

Hot water flexible tail pipe 

 

Cold water flexible tail pipe 

 

 

 

After installation: 

 

Once you have visually checked the installation of the new tap and all connections, ensure that all other fittings are 
closed except the new tap which should be left open.  
 
Turn on your water heating system and ensure that your mains stopcock is open. Reconnect both the hot and cold 
water supplies to this fitting. 
 
Check the function of flow and function of hot, cold and mixed water. 
 
Turn off the tap and check carefully for any leaks around all connections on the fitting and adjoining plumbing. 
If possible return to the installation after a longer period to double check for slower leaks. If pressure testing 
equipment is available check the installation to the maximum recommended pressure. 
 
Clean the tap to remove any marks created during installation as instructed then place a bag over the product to 
protect the tap until it is ready for use. 
 
The installation should be periodically checked for damage, if the property is left unattended for a prolonged period 
we recommend isolating water supplies. 

 

Correct use of flexible hose connectors

 

 

 
This product is supplied with flexible hose connections for ease of fitting, failure to observe these 
standard installation guidelines will invalidate the warranty for your product. 

 

 

 

 

 

Before assembling the hose to the 
product ensure the hose has been 
crimped (as highlighted) on both 
ends of the hose after the braided 
casing.

 

 
 

 

            

 

 

  Always screw the flexi hoses into 

the product only by hand until 
feeling mechanical rest, a spanner 
must not be used on the product 
connecting end of the hose. 
 

 

Always use the pipes provided.

 

 

    

 

 

  Never twist or stretch the flexible 

hose during installation. 
 

 

Do not overtighten the hexagonal 
end of the hose when using a 
spanner causing the hose to twist.

 

Содержание TAP9160

Страница 1: ...t exit it can be removed and cleaned periodically to maintain optimum flow performance Important Technical Data Minimum operating pressure 1 0 bar Maximum hot water temperature 70 C Maximum operating pressure 5 5 bar Recommended hot water temperature 46 C Flow characteristics Single flow If these temperatures or pressures are exceeded even for short periods damage can result In these instances a t...

Страница 2: ...g surface available and reach the required outlet positions before installation Loosely position the tap and tail pipes to check if any alteration to the existing pipework is required if this is the case do this now Installation 1 Screw in the fixing stud D into the base of the tap A 2 Place the base plinth B then upper seal C over the fixing stud D to the base of the tap body A 3 Screw the hot an...

Страница 3: ...mmended pressure Clean the tap to remove any marks created during installation as instructed then place a bag over the product to protect the tap until it is ready for use The installation should be periodically checked for damage if the property is left unattended for a prolonged period we recommend isolating water supplies Correct use of flexible hose connectors This product is supplied with fle...

Страница 4: ...chemicals internal or external room walls or dissimilar metals or materials Observe the minimum bend radius of 50mm hoses must not be kinked or looped Hoses must not be double bent in multiple directions Both ends of the hose must have a minimum 50mm straight section before any bend 50mmØ ...

Отзывы: